ABB - Installation Products K151-SR-C2240 - Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

ABB Installation Products K151-SR-C2240 Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.805 inch…

UPC: 783786504862


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151-SR-C2240 Straight Receptacle is a deadbreak-rated medium voltage connection solution designed for 200 Amp, 15/25 kV electrical systems. This receptacle provides a secure and reliable interface for medium voltage cable terminations, ensuring safe power distribution in critical applications. The unit accommodates cable insulation diameters between 0.805 inches and 1.060 inches, making it compatible with a range of medium voltage cables commonly used in industrial and utility environments. Engineered with a copper compression lug, the K151-SR-C2240 delivers robust electrical contact and long-term performance. The lug supports compressed stranded conductor sizes of 1/0 AWG, solid conductor sizes of 2/0 AWG, or equivalent metric sizes of 53.49 mm². The deadbreak design enables safe disconnection under load conditions when used with a compatible mating elbow connector, reducing downtime during maintenance or system modifications. This receptacle is ideal for medium voltage applications in substations, industrial facilities, utility power distribution networks, and other environments where dependable electrical connections are essential. Its deadbreak feature ensures operational safety during live-line work, minimizing the risk of arc flash or electrical hazards. The ABB K151-SR-C2240 is part of ABB’s Installation Products line, offering a trusted solution for medium voltage cable terminations with a focus on reliability and performance.
  • Rated for 200 Amps at 15/25 kV for medium voltage applications
  • Deadbreak design allows safe disconnection under load conditions
  • Accommodates cable insulation diameters from 0.805" to 1.060"
  • Copper compression lug supports 1/0 AWG compressed stranded, 2/0 AWG solid, or 53.49 mm² conductors
  • Compatible with mating elbow connectors for secure medium voltage cable terminations

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.

K655YSR-H0250

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.
Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. With 150TB6 Bail.

K152SR-B0240-150TB6

Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. With 150TB6 Bail.
Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K152SR-A0250

Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
Elbow, 600 Amp, Deadbreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

655LR-F0220

Elbow, 600 Amp, Deadbreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
Elbow, 600 Amp, Connector, Deadbreak, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 or Compacted /Solid 900.

655LR-L0380

Elbow, 600 Amp, Connector, Deadbreak, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 or Compacted /Solid 900.
Elbow, 600 Amp, Connector, Deadbreak, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil, Compressed / Stranded 700/750 or Compacted / Solid 900.

655LR-M0380

Elbow, 600 Amp, Connector, Deadbreak, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil, Compressed / Stranded 700/750 or Compacted / Solid 900.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K656CY-L2360

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

Frequently Asked Questions

What is the K151SR Deadbreak Straight Receptacle's primary function?

It is a fully shielded, fully submersible separable insulated connector designed to connect a cable to another cable or apparatus.

What is the maximum phase-to-ground operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

What is the one-minute AC withstand voltage for 15kV class?

For the 15kV voltage class, the one-minute AC withstand voltage is 34kV.

What is the impulse withstand rating for the 25kV class?

For the 25kV voltage class, the impulse withstand (BIL) is 125kV.

What is included in each K151SR kit?

Each kit contains one straight receptacle housing, one receptacle pin connector, one tube of lubricant, installation instructions, and a crimp chart.

What standards does the K151SR meet?

The K151SR meets ANSI/IEEE Standard 386, Latest Revision.

What is the maximum phase-to-ground operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

What cable insulation diameters are compatible with the K151SR?

The K151SR accommodates cable insulation diameters ranging from .575 inches through 1.220 inches.

What conductor sizes can the K151SR accommodate?

The K151SR can accommodate conductor sizes from No. 4 solid through 4/0 stranded.

What is the continuous current rating for the K151SR?

The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.

How to Install the Elastimold 151SR/K151SR Straight Receptacle

This guide provides detailed instructions for installing the Elastimold 151SR/K151SR Straight Receptacle, covering cable preparation, conductor crimping, and connection to mating products. Ensure all apparatus are de-energized before starting.

Estimated time: 1h

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimp tool, Rag

Supplies needed:

Elastimold 151SR/K151SR Straight Receptacle, Conductor contact (male), Nylon venting rod, Lubricant (supplied), Crimp chart, Approved solvent, Silicone grease, Elastimold bail, Copper wire (#14 AWG or equivalent), Sealing material (for grounding)

  1. De-energize and Prepare Cable Jacket

    DANGER: Ensure all apparatus are de-energized before installation. Cut and remove the cable jacket: 8 inches for jacketed concentric neutral cables, or 7 1/2 inches for copper tape shield cables. For copper tape shield, remove the tape 6 1/2 inches from the cable end. Allow sufficient concentric neutral wires for grounding as required by the installation.

  2. Prepare Conductor and Insulation

    Remove 7/8 to 1 inch (or 1 3/4 to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable) of cable insulation and conductive shield. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel, which contains inhibitor. Cut the cable squarely; do not pencil the cut.

  3. Crimp Socket Terminal

    Crimp the socket terminal onto the bared conductor, ensuring it remains fully seated in the connector. Refer to the crimp chart for specific instructions. Start crimps at the imprinted crimp line and rotate each successive crimp 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.

  4. Prepare Semi-Conductive Shield and Clean Insulation

    Remove the semi-conductive shield 7 9/16 to 7 5/8 inches from the pin end with a straight, smooth, squared cut; avoid cutting or nicking the insulation. Pencil the insulation 1/8 inch. Thoroughly clean the outer jacket and insulation with an approved solvent, wiping from the cable end towards the outer jacket to remove all semi-conducting residue. Install an ECS or MA grounding device if applicable, following its instructions.

  5. Lubricate Receptacle and Cable

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do NOT substitute lubricants, as other types may be harmful to this product or its mating product.

  6. Insert Cable into Receptacle Housing

    Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. IMPORTANT: If the receptacle is not to be immediately connected, replace the protective cover. Note that the shipping cover only offers protection from dirt and is NOT an insulating device; obtain an Elastimold insulating plug (K150DP) if an insulating device is required.

  7. Connect to Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care to ensure the nylon rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail.

  8. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Then, connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.