ABB Installation Products K655YSR-K0330 600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable…
UPC: 783786479955
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 600 Amps at 15/25kV medium-voltage systems
- Dead-break straight receptacle design for safe under-load connections
- Compatible with compressed stranded 500 kcmil or solid 600 kcmil (250/300 mm²) conductors
- Cable insulation diameter range: 1.090 to 1.310 inches
- Aluminum compression lug for reliable conductivity and mechanical strength
Specifications
Amperage Rating | 600 A |
Application | These Connectors allow a straight cable connection on Switchgear or Electrical Apparatus equipped with 600 Amp Bushings |
Color | Black |
Conductor Range | 500 kcmil , 600 kcmil |
Connection | Compression |
Connection Type | Dead Break |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 16.98 in |
Length | 431.292 mm |
Material | Housing - EPDM-Rubber |
Material | Aluminum |
Series | K655YSR |
Size | Cable Insulation Diameter 1.090 inch to 1.310 inch |
Special Features | Fully Shielded, Fully Submersible, Can be easily Connected or Disconnected in a De-Energized State |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 6.6000 L |
Package Weight (Metric) | 2.9940 kg |

K655LR-J0330
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
K151-SR-C2240
Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
K655YSR-H0250
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.
K152SR-B0240-150TB6
Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. With 150TB6 Bail.
K152SR-A0250
Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
655LR-F0220
Elbow, 600 Amp, Deadbreak, 15/25KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
655LR-L0380
Elbow, 600 Amp, Connector, Deadbreak, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 700/750 or Compacted /Solid 900.Frequently Asked Questions
What items are included in the K655YSR kit?
Each kit contains a receptacle housing, lubricant, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, instruction sheet, and bolts and washers.
Is the K655YSR receptacle submersible?
Yes, the K655YSR features a fully shielded and fully submersible molded rubber housing.
What is the momentary current rating?
The momentary current rating for the K655YSR is 25kA Symmetrical for 10 cycles.
What is the continuous current rating of the receptacle?
The K655YSR receptacle has a continuous current rating of 600 Amps for both 15kV and 25kV voltage classes.
What is the maximum operating voltage for 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and phase-to-phase is 28kV.
What is the maximum operating voltage for 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and phase-to-phase is 14.4kV.
What cable insulation diameters does K655YSR support?
The K655YSR supports cable insulation diameters ranging from .640 inches to 1.935 inches.
What conductor sizes are compatible with K655YSR?
The K655YSR supports aluminum and copper conductors from #2 AWG to 1250 kcmil.
What is the K655YSR product used for?
The K655YSR provides a fully shielded, submersible cable connection on 15/25kV high-voltage “I”, “Y”, or “H” Bus, connecting to 600 Amp bushings.
What items are included in the K655YSR kit?
Each kit contains a receptacle housing, lubricant, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, instruction sheet, and bolts and washers.
How to Install K656/676 Series Deadbreak Receptacles
This guide provides step-by-step instructions for the safe installation and wiring of K656/676 series deadbreak receptacles, designed for splicing and tapping solid dielectric cables. Ensure all safety precautions are followed for high voltage equipment.
Estimated time: 2h
Tools needed:
Hex wrench, Torque wrench (with 15/16 inch socket), Wire brush (for aluminum cable), Wire strippers, Utility knife, Beveling tool, 650ATY assembly tool (optional), 600RRT assembly tool (optional)
Supplies needed:
Receptacle housings, Cable adapters, Center sections (I, Wye, or H), Aluminum holding collars, Lubricant, Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, No. 14 AWG copper wire, Tape markers, Approved safety solvent, Cleaning rags
- Ensure Safety and Prepare Workspace
DANGER: All apparatus must be de-energized during installation. Inspect all parts for damage, rating, and compatibility. Gather all required tools and supplies, maintaining cleanliness. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors if submerging or energizing the circuit.
- Prepare the Cable End
Wipe the outer jacket clean for 38 inches and cut the cable end squarely to ensure maximum length for crimp growth. If using an ECS grounding device, slide its tube onto the cable. Slide the receptacle housing onto the cable for 30 inches. Refer to the specific cable preparation supplement for your cable type (e.g., remove jacket, semi-con, bevel insulation, clean, and lubricate before sliding the cable adapter).
- Assemble Conductor and Crimp Connector
Remove protruding cable insulation, cutting it even with the cable adapter end. Do not nick the adapter or conductor. Verify exposed conductor is 4 3/4” - 5”. Assemble the aluminum retaining ring over the conductor, snug against the cable adapter, and hand-tighten the socket head screw. Confirm exposed conductor is 4 3/8” - 4 3/4”. Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector. Confirm bolt holes align with the mating part. Crimp connectors, rotating each crimp 90 or 180 degrees. Verify distance from connector end to holding collar is 6 3/4” - 7” Max after crimping. Repeat for all cables.
- Secure Connections and Lubricate
Assemble the flat washer against the spade contact, followed by the Belleville washer (concave side down), and then the hex-head bolt. Hand tighten. Do not move or reposition the assembly after the bolts are tightened. Using a torque wrench with a 15/16” socket, tighten all bolts to 50 to 60 ft. lbs. Apply the supplied lubricant generously to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing.
- Install Receptacle Housing and Ground
Slide the receptacle housing over the cable adapter and up to the interface edge. Insert the nylon venting rod. Use an assembly tool (650ATY or 600RRT) to slowly slide the receptacle housing over the splice section. Remove the venting rod. WARNING: Do not place hands on the threaded rod or guide shaft with the assembly tool in place. Repeat for all remaining cables. Check all cable adapters are properly located and remove any vinyl tape markers. Complete the ECS grounding device installation. Connect a No. 14 AWG copper wire to the grounding eyes of the housings, forming a small loop and twisting tightly, then connect to ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.