ABB Installation Products K655VSL3-N0410-S 15/25kV, 600 Amp, 3-Way Vault Stretcher Kit, Cable Insulation Diameter 1.515-1.780…
UPC: 075114321099
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV voltage rating with 600A continuous current capacity
- Accommodates cable insulation diameters from 1.515 to 1.780 inches
- Aluminum compression lugs for 1000 stranded/compressed conductors
- Fully shielded, submersible molded rubber housing per ANSI/IEEE Standard 386
- 140kV BIL impulse withstand and 45kV AC one-minute withstand rating
- 3-way design for efficient branching of medium-voltage circuits
- Integrated sealing kit for environmental protection in wet/corrosive conditions
- Rated for 25kA symmetrical momentary current for 10 cycles
- Includes compression lugs, studs, insulated plugs, lubricant tubes, and installation instructions
- Compatible with optional accessories for separation, bypass, isolation, grounding, and testing
Specifications
Application | 15/25 kV, 600 Amps |
Connection Type | Compression Lug |
Connection Type | Compressed |
Current Rating | 600 A |
Material | Aluminum |
Poles | 3-Way |
Series | Vault Stretcher Kit |
Series | K655VSL3 |
Size | Cable Insulation Diameter 1.515-1.780 inches |
Size | 1.515-1.780 inch (insulation diameter) |
Type | 3-Way Vault Stretcher Kit |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655BLR-K0330
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.
K656BLR-BIP
15/25 kv, 600 Amp Series Elbow, DeadBreak, Housing Only with Stud, With Basic Insulating Plug, No Seal
K656CCP-M0300
25kV, 600 Amps, Combo T connecting Plug with Bus Stud, Cable Adapter and Lug Kit, No Sealing Kit, Cable Insulation Diameter 1.3701-1.630 inches (34.8-41.4mm), Aluminum Lug, 300 Stranded/Compressed, 400 Solid/Compact.
K655CBW-M0380-BWP
15/25kV, 600 Amp, no test point, Combo T Bushing Well with Stud, Cable Adapter and Lug Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 750 kcmil or Compacted/Solid 900 kcmil. BWP - with Bushing Well Plug.Frequently Asked Questions
How do I order the 3-Way Vault Stretcher Kit?
To order the 15/25kV, 600A 3-Way Vault Stretcher, specify K655VSL3.
What items are included in the K655VSL3 kit?
The kit includes the vault stretcher housing, insulating plugs with caps, a connecting plug, an elbow connector housing, lubricant, a stud, and two installation instructions.
How should the K655VSL3 be connected or disconnected?
It can be connected or disconnected using standard hand tools and equipment, but only in a de-energized state.
What components are compatible with the K655VSL3 vault stretcher?
It can be mated with K651CP, K650BIP, K650RTP, K650RTW, K650S1, K650T1, K650JX, and K650ETP.
What standard does the K655VSL3 meet?
The K655VSL3 meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating (BIL) of the K655VSL3?
The impulse withstand (BIL) rating is 140kV (1.2 x 50 microsecond wave).
What is the continuous current rating of this vault stretcher?
The K655VSL3 has a continuous current rating of 600 Amp.
What is the maximum operating voltage for the K655VSL3?
The maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase voltage is 28kV.
What is the voltage class of the K655VSL3?
The K655VSL3 is designed for a 15/25kV voltage class.
What components are compatible with the K655VSL3 vault stretcher?
It can be mated with K651CP, K650BIP, K650RTP, K650RTW, K650S1, K650T1, K650JX, and K650ETP.
How to Install 15/25/35kV 600/900 AMP Deadbreak Plug and Well Products
This guide provides step-by-step instructions for the safe installation and initial setup of 15/25/35kV 600/900 AMP Deadbreak Plug and Well products, including connection and voltage testing procedures.
Estimated time: 1h
Tools needed:
Torque wrench, ELASTIMOLD 600SW spanner wrench (if applicable), Hotstick, Suitable sensing device for capacitive test points
Supplies needed:
Plug or Well product, Lubricant (supplied, DO NOT SUBSTITUTE), HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone lubricant (for test point cap)
- De-energize and Inspect Apparatus
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Do not touch or move energized products in the work area. Inspect all parts for damage, correct rating, and compatibility with mating parts. Verify the package contents are complete and undamaged. If the product came with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.
- Prepare and Lubricate Components
Remove any remaining protective caps from the plug or well product. If the 600amp mating interface is not equipped with a stud, hand tighten the stud into the 600amp interface on the plug or well. Lubricate both the elbow and its mating part as indicated with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Ensure all surfaces of the elbow and mating parts are clean.
- Connect the Plug/Well and Torque Tighten
Push the plug or well firmly into the elbow or bushing extension until the threads engage. For Insulating Plugs: Use a torque wrench and tighten the connection to 50 to 60 foot-pounds of torque. For Connector Plugs, Tap Plugs, or Tap Wells: Use a torque wrench with an ELASTIMOLD 600SW spanner wrench. Tighten to an indicated torque of 40 to 48 foot-pounds.
- Install Voltage Detection Cap (if applicable)
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap with silicone lubricant. Place the cap onto the elbow and push down hard until it snaps securely into place.
- Perform Voltage Test
WARNING: This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment. Remove the test point cap from the capacitive test point using a hotstick. Peel it off at an angle rather than pulling directly in line with the assembly. WARNING: The voltage test point is a capacitance device and is NOT directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for separable connectors with capacitive test points, following the manufacturer's directions for the meter. Test with the suitable sensing device to determine if the cable is energized. DANGER: Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the test point cap with silicone lubricant and replace it securely on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.