ABB - Installation Products K655SR-M0360 - 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.

ABB Installation Products K655SR-M0360 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and…

UPC: 783786350568


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655SR-M0360 is a 600 Amp, 15/25 kV deadbreak straight receptacle from ABB's 600 Series, designed for reliable medium-voltage cable terminations. This unit includes a cable adapter, an aluminum compression lug, and a retaining ring, specifically engineered for cable insulation diameters ranging from 1.370 to 1.630 inches. It supports compressed stranded conductors up to 650 kcmil or compacted solid conductors up to 750 kcmil, with provisions for double hole lugs up to (2) 750 kcmil Cu/Al. The aluminum construction ensures durability and corrosion resistance in demanding industrial and utility environments. The deadbreak configuration enhances operational safety by allowing connection and disconnection without de-energizing the system. This receptacle is suitable for medium-voltage distribution, substations, and industrial power networks. The integrated retaining ring ensures secure cable adapter placement. ABB's 600 Series is recognized for its performance in critical electrical systems.
  • 600 Amp current rating
  • 15/25 kV voltage rating
  • Deadbreak straight receptacle connection type
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Includes aluminum compression lug and retaining ring

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
650 kcmil , 750 to 800 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K655L3-LM0360

15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K655SR-K-0330

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Compacted Solid 350 or mmSquared Compact 150. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655SR-K0290-SG3

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Compacted Solid 350 or mmSquared Compact 150. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K655SR-N-0330

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.

K655SR-M-0410

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.

K655SR-K-0320

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

K655SR-H-0270-S

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

K656DLR-F0260

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

Frequently Asked Questions

What is the K655SR product designed for?

The K655SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings. It allows a straight cable connection on switchgear or electrical apparatus with 600 Amp bushings.

What standard does the K655SR meet?

The K655SR meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating for 28kV?

For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).

What is the impulse withstand rating for 15kV?

For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).

What items are included in a K655SR kit?

Each kit includes a straight receptacle housing, lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

What materials are used in the K655SR construction?

The K655SR features 100% peroxide-cured construction, including insulation and conductive EPDM materials.

What type of housing does the K655SR have?

The K655SR features a fully shielded, fully submersible molded rubber housing.

What are the operating voltage limits for 28kV class?

For the 28kV class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What are the operating voltage limits for 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What is the maximum continuous current rating?

The K655SR has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.

How to Install the K655SR/M655SR Deadbreak Straight Receptacle

This guide provides step-by-step instructions for the safe and proper installation of the K655SR and M655SR deadbreak straight receptacles, which provide an in-line cable connection to standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushings. All apparatus must be de-energized during installation to prevent serious or fatal injury.

Estimated time: 2h 30m

Tools needed:

5/8-11 Tap, Torque Wrench (with 15/16 socket), Wire Brush (for aluminum cable), Crimp Tool, Wire Strippers, Hex Wrench, Hose Clamp (for 35kV only)

Supplies needed:

Receptacle Housing, Bushing Adapter, Cable Adapter, Aluminum Holding Collar, Hex Head Bolt, Crimp Connector (with inhibitor if aluminum), Belleville Washer, Flat Washer, Nylon Venting Rod, Lubricants (supplied), Brass Bolt, Bushing Converter Contact, Loctite, Electrical Tape (for tape marker), No. 14 AWG Copper Wire (or equivalent), Suitable Connector (for neutral wires)

  1. Prepare Apparatus Bushing and Assemble Converter

    If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using the 5/8” brass bolt. Torque to 60 ft.-lbs.

  2. Prepare Cable End and Neutral Wires

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth. If applicable, unwrap the concentric neutral wires a distance of 30” (76cm); do not cut them, but bend and fold them back out of the way. Wipe the outer jacket clean a distance of 38” (96.5cm) or up to the concentric neutral wires.

  3. Slide Receptacle Housing and Prepare Cable Insulation

    Slide the receptacle housing onto the cable a distance of 30” (76cm). Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4” (26.04cm) from the end of the cable insulation to the tape marker, and 11-1/4” (28.58cm) from the end of the semi-con shield to the tape marker). Do not cut or nick the cable insulation.

  4. Install Cable Adapter and Expose Conductor

    Bevel the end of the cable insulation at a 45˚ angle, approximately 1/4” (6mm) back. Thoroughly clean, then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4 3/4” – 5” (12.06cm – 12.7cm); otherwise, redo the assembly.

  5. Position Holding Collar and Prepare Crimp Connector

    Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew. Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar; if it is over 7” (17.8cm), do not proceed and redo all previous work.

  6. Confirm Alignment and Crimp Connectors

    Confirm that all components are oriented in the correct order: Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter. Crimp the connectors following the instructions packaged with the connectors, rotating each crimp 90˚. After crimping, measure the distance from the end of the connector to the holding collar; if it is over 7” (17.8cm), do not proceed and redo all previous work.

  7. Assemble and Torque Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. The splice and cables are now in their final positions. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  8. Lubricate and Seat Receptacle Housing

    Apply the supplied lubricant or an ELASTIMOLD approved lubricant generously to the outside of the cable adapter and the area of the bushing adapter as shown in the documentation. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod.

  9. Connect Grounding and Neutral Wires

    Connect a short piece of No. 14 AWG copper wire or equivalent to the grounding eye of the receptacle housing. Make a small loop and twist tightly, taking care not to damage the eye. Gather together the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire together.

  10. Install Hose Clamp (35kV Only)

    For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.