ABB Installation Products K655SR-J0240 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and…
UPC: 783786093861
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp current rating
- 15/25kV voltage rating
- 600 Series Deadbreak Straight Receptacle
- Includes Cable Adapter, Aluminum Compression Lug, and Retaining Ring
- Accommodates cable insulation diameter: 0.980" - 1.180"
Specifications
Amperage Rating | 600 A |
Application | 15/25kV, 600 Amps |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions, Fully Submersible |
Insulation | True |
Length | 16.98 in |
Length | 431.292 mm |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Series | 600 Series |
Size | Cable Insulation Diameter 0.980 inch to 1.180 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 8.0000 L |
Package Weight (Metric) | 3.6290 kg |

756LR-L0240
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
K656DLR-L0320-SG3
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
K655SR-G-0240-S
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.
K655SR-L-0360-S
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400. Cold-Shrinkable Jacket Seal Included.
K655SR-M0360
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.
K655SR-K-0330
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
K655SR-K0290-SG3
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Compacted Solid 350 or mmSquared Compact 150. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.Frequently Asked Questions
What is the maximum operating voltage for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and phase-to-phase is 14.4kV.
What is the continuous current rating of the K655SR?
The K655SR has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.
What insulation diameters does the K655SR support?
The K655SR is compatible with cable insulation diameters ranging from 0.640 inches to 1.935 inches.
What conductor sizes are compatible with K655SR?
The K655SR product range supports #2 AWG to 1250 kcmil for both aluminum and copper conductors.
What is the K655SR product designed for?
The K655SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings. It allows a straight cable connection on switchgear or electrical apparatus equipped with 600 Amp bushings.
What is the maximum operating voltage for the 28kV class?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and phase-to-phase is 28kV.
Is the K655SR suitable for submersible applications?
Yes, the K655SR features a fully shielded and fully submersible molded rubber housing.
What standard does the K655SR meet?
The K655SR meets ANSI/IEEE Standard 386, Latest Revision.
Is the K655SR suitable for submersible applications?
Yes, the K655SR features a fully shielded and fully submersible molded rubber housing.
What is the K655SR product designed for?
The K655SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings. It allows a straight cable connection on switchgear or electrical apparatus equipped with 600 Amp bushings.
How to Install the K655SR/M655SR Deadbreak Straight Receptacle
This guide provides step-by-step instructions for the safe and proper installation of the K655SR and M655SR deadbreak straight receptacles, connecting an in-line cable to an ANSI-386 600 amp bushing. Ensure all apparatus is de-energized before beginning installation.
Estimated time: 2h
Tools needed:
5/8-11 tap (if applicable), Hex wrench (supplied), Wire brush (for aluminum cable), Torque wrench with 15/16 socket, Suitable connector (for neutral wires)
Supplies needed:
Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricants (supplied or ELASTIMOLD approved), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire (or equivalent), Hose Clamp (M655SR for 35kV only)
- Prepare the Apparatus Bushing
Ensure the apparatus is de-energized. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using the 5/8” brass bolt. Torque the bolt to 60 ft.-lbs.
- Prepare the Cable End
Train the cable end and straighten it into its final position. Cut the cable end squarely to ensure maximum available length for crimp growth. If applicable, unwrap the concentric neutral wires a distance of 30” (76cm), bend them back, and fold them out of the way without cutting. Wipe the outer jacket clean for a distance of 38” (96.5cm) or up to the concentric neutral wires.
- Install Receptacle Housing and Prepare Cable Insulation
Slide the receptacle housing onto the cable a distance of 30” (76cm). Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4” (26.04cm) from the end of cable insulation, 11-1/4” (28.58cm) from the end of the semi-con shield). Do not cut or nick the cable insulation.
- Install Cable Adapter and Expose Conductor
Bevel the end of the cable insulation at a 45˚ angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter, ensuring not to cut or nick the cable adapter or conductor. The exposed conductor length should be 4 3/4” – 5” (12.06cm – 12.7cm); otherwise, redo the assembly.
- Position Holding Collar and Prepare Crimp Connector
Position the holding collar over the conductor, flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew. Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, ensuring it is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar; if it is over 7” (17.8cm), redo all previous work.
- Confirm Orientation and Crimp Connectors
Confirm that the components are oriented in the order: Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter. Crimp the connectors following their packaged instructions, rotating each crimp 90˚. After crimping, measure the distance from the end of the connector to the holding collar; if it is over 7” (17.8cm), redo all previous work.
- Assemble Washers and Bolt
Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the assembly. Using a torque wrench with a 15/16 socket, tighten the bolt to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.
- Lubricate and Seat Receptacle Housing
Generously apply the supplied lubricant or an ELASTIMOLD approved lubricant to the outside of the cable adapter and the bushing adapter area. DO NOT SUBSTITUTE other lubricants. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated, then remove the venting rod.
- Ground the Receptacle Housing and Neutral Wires
Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, forming a small loop and twisting tightly without damaging the eye. Gather the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire together.
- Secure with Hose Clamp (35kV ONLY)
For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.