Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655SR-H0270 - 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.

ABB Installation Products K655SR-H0270 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and…

UPC: 783786022915


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products K655SR-H0270 is a 600 Amp, 15/25kV deadbreak straight receptacle designed for medium-voltage cable connections in industrial and utility applications. This 600 Series component features a deadbreak connection type, ensuring safe and reliable operation under load without interrupting service. The unit includes a cable adapter, aluminum compression lug, and retaining ring for secure termination of cables with insulation diameters between 0.850 inch and 1.050 inch. Key specifications include a 600 Amp current rating and compatibility with compressed stranded conductors sized 4/0 AWG or compacted solid conductors up to 250 kcmil (125 mm²). The aluminum construction provides lightweight durability while maintaining electrical integrity in harsh environments. This deadbreak receptacle is ideal for underground distribution systems, switchgear, and transformer connections where reliable, maintenance-free operation is critical. The K655SR-H0270 is part of ABB’s 600 Series, a trusted line of medium-voltage accessories known for precision engineering and long-term performance. Installation requires no special tools beyond standard compression equipment, reducing downtime during setup. The deadbreak design allows for hotstick operation, enabling safe connection and disconnection under load conditions. Use this receptacle in applications such as utility substations, industrial plants, renewable energy projects, and commercial buildings where medium-voltage cable terminations demand reliability and compliance with industry standards. The product meets UNSPSC Code 39121421 for electrical connectors and accessories.
  • 600 Amp current rating for medium-voltage applications
  • 15/25 kV voltage rating with deadbreak connection type
  • Compatible with 0.850–1.050 inch cable insulation diameters
  • Includes aluminum compression lug for 4/0 AWG to 250 kcmil conductors
  • Part of ABB’s 600 Series for reliable medium-voltage terminations

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation .980-1.180 inches, Aluminum Compression Lug, Conductor Size 350 Stranded/Compressed or 400 Solid/Compact

K655DLR-J0300

15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation .980-1.180 inches, Aluminum Compression Lug, Conductor Size 350 Stranded/Compressed or 400 Solid/Compact
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil, Compressed Stranded 350 or Solid/Compacted 400.

K655DLR-M0300

15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil, Compressed Stranded 350 or Solid/Compacted 400.
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.515-1.780 inches, Aluminum Compression Lug, Conductor Size 1000 Stranded/Compressed

K655DLR-N0410

15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.515-1.780 inches, Aluminum Compression Lug, Conductor Size 1000 Stranded/Compressed
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.

K655SR-J0270

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.

K655SR-H0260

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Compacted Solid 4/0 or mmSquared Compact 95.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 4/0 or Compacted Solid 250 or mmSquared Compact 125.

K655SR-F0270

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 4/0 or Compacted Solid 250 or mmSquared Compact 125.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 250 or Compacted Solid 300.

K655SR-J0280

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 250 or Compacted Solid 300.

Frequently Asked Questions

What is the K655SR product used for?

The K655SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings, allowing a straight cable connection on switchgear or electrical apparatus equipped with 600 Amp bushings.

What is the continuous current rating of the K655SR?

The K655SR has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.

What standards does the K655SR meet?

The K655SR meets ANSI/IEEE Standard 386, Latest Revision.

What type of housing does the K655SR have?

The K655SR features a fully shielded, fully submersible molded rubber housing. Its construction includes 100% peroxide-cured insulation and conductive EPDM materials.

What is the impulse withstand (BIL) for 28kV class?

For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).

What is the impulse withstand (BIL) for 15kV class?

For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).

What are the operating voltage ratings for 28kV class?

For the 28kV class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What are the operating voltage ratings for 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What is the insulation diameter range for cables?

The K655SR is compatible with cables having insulation diameters from 0.640 inches to 1.935 inches.

What conductor sizes are compatible with K655SR?

The K655SR product range accommodates #2 AWG to 1250 kcmil for aluminum and copper conductors.

How to Install the K655SR/M655SR Deadbreak Straight Receptacle

This guide provides step-by-step instructions for installing the K655SR or M655SR Deadbreak Straight Receptacle, which provides an in-line cable connection to a standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushing.

Estimated time: 1h 30m

Tools needed:

5/8-11 tap, Hex wrench, Torque wrench, 15/16 socket, Wire brush, Wire strippers, Hose clamp (for 35kV only), Nylon venting rod

Supplies needed:

Loctite, ELASTIMOLD approved lubricant, Tape marker, No. 14 AWG copper wire or equivalent, Suitable connector

  1. Prepare Apparatus Bushing

    DANGER: All apparatus must be de-energized during installation. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using the 5/8” brass bolt. Torque to 60 ft.-lbs.

  2. Prepare Cable End

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.

  3. Unwrap Concentric Neutral Wires (If Applicable)

    If applicable, unwrap the concentric neutral wires a distance of 30” (76cm). DO NOT CUT these wires; instead, bend and fold them back out of the way.

  4. Clean Outer Jacket and Slide Receptacle Housing

    Wipe the outer jacket clean a distance of 38” (96.5cm) or up to the concentric neutral wires. Slide the receptacle housing onto the cable a distance of 30” (76cm).

  5. Prepare Semi-Con Shield

    Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4” to 11-1/4”). Be careful not to cut or nick the cable insulation during this process.

  6. Install Cable Adapter

    Bevel the end of the cable insulation at a 45˚ angle, approximately 1/4” (6mm) back. Thoroughly clean, then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  7. Expose Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4 3/4” – 5” (12.06cm – 12.7cm). If the length is incorrect, redo the assembly from previous steps.

  8. Position Holding Collar

    Position the aluminum holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew.

  9. Prepare Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  10. Confirm Component Orientation

    Confirm that the components are oriented in the correct order: Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  11. Crimp Connectors

    Crimp the connectors following the specific instructions packaged with the connectors. Rotate each crimp 90˚. After crimping, measure the distance from the end of the connector to the holding collar. If this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  12. Assemble Washers and Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the assembly. The splice and cables are now in their final positions. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  13. Lubricate Adapters

    Apply the supplied lubricant or an ELASTIMOLD approved lubricant generously to the outside of the cable adapter and the area of the bushing adapter as shown in the documentation. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.

  14. Seat Receptacle Housing and Ground

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod. Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, making a small loop and twisting tightly without damaging the eye. Gather together the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire.

  15. Position Hose Clamp (35kV Only)

    FOR 35kV ONLY: Position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.