ABB - Installation Products K655LR-G0250 - 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0 or mm2 70.

ABB Installation Products K655LR-G0250 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600…

UPC: 783786644520


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655LR-G0250 is a 600 Amp Dead Break Elbow Kit designed for 15/25KV applications. This kit includes an insulated plug, cap, stud, lug, and cable adapter, providing a complete solution for connecting cables in medium voltage systems. It is engineered to accommodate cable insulation diameters ranging from 0.760 inches to 0.950 inches. The included aluminum compression lug is suitable for conductor sizes of 2/0 AWG compressed/stranded or 3/0 AWG solid/compact, and 70 mm². This Dead Break Elbow Kit from ABB Installation Products ensures reliable and safe terminations for power distribution networks. Its design facilitates a secure connection, crucial for maintaining system integrity and preventing outages. The 600 Amp rating signifies its capacity for handling significant electrical loads within its specified voltage class. Key components of the K655LR-G0250 kit: * **Voltage Rating:** 15/25KV * **Amperage Rating:** 600 Amp * **Termination Type:** Dead Break * **Cable Insulation Diameter Range:** 0.760" - 0.950" * **Lug Type:** Aluminum Compression * **Conductor Size Compatibility:** 2/0 AWG (Compressed/Stranded), 3/0 AWG (Solid/Compact), 70 mm² This product is essential for utility, industrial, and commercial power distribution infrastructure where robust and dependable cable terminations are required.
  • 600 Amp, 15/25KV Dead Break Elbow Kit
  • Accommodates cable insulation diameter from 0.760" to 0.950"
  • Includes insulated plug, cap, stud, lug, and cable adapter
  • Aluminum compression lug for 2/0 AWG (Compressed/Stranded) or 3/0 AWG (Solid/Compact) / 70 mm² conductors
  • ABB Installation Products SKU: K655LR-G0250

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Weight (Imperial)
7.2500 L
Package Weight (Metric)
3.2890 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 3/0 or Solid/Compact 4/0 or mm2 95.

K655LR-G0260

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 3/0 or Solid/Compact 4/0 or mm2 95.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-J0300

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-G0240

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size kcmil Compressed/Stranded 250 or Compact/Solid 300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655LR-G0280-SG3

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size kcmil Compressed/Stranded 250 or Compact/Solid 300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-K0290-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400.

K656LR-L0360

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-K5330-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

What is the maximum operating voltage for this elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground. For the 28kV voltage class, it is 16.2kV phase-to-ground.

What conductor sizes can this elbow connector accommodate?

It can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this device?

The continuous current rating for this elbow connector is 600 Amps.

What is the insulation diameter range for compatible cables?

The compatible insulation diameters range from 0.640 inches to 1.935 inches.

What standards does this elbow connector meet?

This elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating for the 28kV voltage class is 140kV BIL for a 1.2 x 50 microsecond wave.

What is the AC one-minute withstand for the 15kV voltage class?

The AC one-minute withstand for the 15kV voltage class is 34kV.

What is the DC 15-minute withstand for the 28kV voltage class?

The DC 15-minute withstand for the 28kV voltage class is 84kV.

What is the corona extinction rating for the 15kV voltage class?

The corona extinction rating for the 15kV voltage class is 11kV AC at 3pC sensitivity.

What is the momentary short-circuit current rating?

The momentary short-circuit current rating is 25kA Sym for 10 Cycles.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K655/K675LR and 655/675LR deadbreak elbow connectors, including cable preparation, component assembly, and grounding procedures for high voltage systems.

Estimated time: 1h

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Torque wrench, Suitable sensing device (for capacitive test points)

Supplies needed:

655/675LR or K655/K675LR Deadbreak Elbow Connector, Cable Adapter, Compression Lug, Insulating Plug (if used as mating part), Lubricant (silicone type recommended), Threaded Stud (if mating part not equipped), No. 14 AWG Copper Wire (or equivalent ampacity for grounding), Suitable Grounding Connector, Tape Marker, HV Insulated Cap(s) or Connector(s) (to replace shipping covers)

  1. De-energize Apparatus and Inspect Parts

    De-energize all apparatus in the work area before beginning installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility with mating parts. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare the Cable for Connection

    Assemble the cable in its final position with enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Follow specific cable preparation instructions (A, B, or C) that apply to your cable type for removing the outer jacket and preparing the shield as shown in the diagrams.

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be between 4-1/4” and 4-9/16” (108mm-116mm). If the length is outside this range, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the “Check Dimension” before crimping; this dimension should be less than 6-3/8”. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8” to 7-1/8” (162mm-181mm). If not, redo the assembly.

  6. Install the Elbow onto the Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  7. Connect the Elbow to the Mating Product

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, lining up the hole in the compression lug with the stud on the mating part. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  8. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with the grounding device. If no grounding device is used, the shield must be grounded through an alternate method. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  9. Perform a Voltage Test (Optional but Recommended)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing down hard until the cap snaps into place. To test for voltage, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Test with a suitable sensing device made for use with separable connectors manufactured with capacitive test points. Treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.