ABB - Installation Products K655LR-F2250 - 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600 Amp, Dead Break, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0 or mm2 70.

ABB Installation Products K655LR-F2250 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, 600…

UPC: 075114252515


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655LR-F2250 is a 600 Series Dead Break Elbow connector designed for reliable 15/25 kV power distribution systems. This unit is rated for 600 Amps and features a copper compression lug for secure conductor termination. Engineered for a cable insulation diameter range of 0.640 inches to 0.820 inches, it accommodates conductor sizes from 2/0 AWG compressed/stranded or 3/0 AWG solid/compact, up to 70 mm². The dead break design ensures safety during connection and disconnection procedures, minimizing exposure to energized components. Included with this elbow are an insulated plug, cap, stud, lug, and cable adapter, providing a complete termination solution. The 600 Series Elbow from ABB Installation Products offers a robust and dependable connection for critical infrastructure. Its construction prioritizes electrical integrity and operational safety in medium-voltage applications. This specific model, SKU K655LR-F2250, is suitable for applications requiring a secure and insulated dead break connection within the specified voltage and current ratings. The copper compression lug ensures a low-resistance, long-lasting electrical interface. Proper installation according to manufacturer guidelines is essential for optimal performance and safety.
  • 15/25 kV Voltage Rating
  • 600 Amp Current Rating
  • Dead Break Connection Type
  • Cable Insulation Diameter: 0.640" - 0.820"
  • Copper Compression Lug for 2/0 AWG Stranded or 3/0 AWG Solid Conductors

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-L5300-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-J5240-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-J5270-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 450 or Compact/Solid 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-H0320-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 450 or Compact/Solid 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed, Cold-Shrinkable Seal with Copper Braid and Constant Force Spring

K656LR-K0380-SG3

15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed, Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid

K656LR-H2270

15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid
25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit

K656LR-J2240-SG3

25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit

Frequently Asked Questions

What is the maximum operating voltage for the K655LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground. For the 28kV voltage class, it is 16.2kV phase-to-ground.

What conductor sizes can the K655LR connector accommodate?

It can be used with conductor ranges from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the insulation diameter range for this elbow connector?

The connector is designed for insulation diameters ranging from 0.640 inches to 1.935 inches.

What is the continuous current rating for the K655LR connector?

The connector has a continuous current rating of 600 Amps.

What is the momentary current rating for the K655LR connector?

The connector has a momentary current rating of 25kA Sym for 10 Cycles.

What is the impulse withstand rating for the 28kV voltage class?

For the 28kV voltage class, the impulse withstand rating is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand voltage for the 15kV class?

For the 15kV voltage class, the AC one-minute withstand voltage is 34kV.

What is the AC one-minute withstand voltage for the 28kV class?

For the 28kV voltage class, the AC one-minute withstand voltage is 45kV.

What is the corona extinction voltage for the 15kV class?

The corona extinction voltage for the 15kV class is 11kV AC at 3pC sensitivity.

What is the corona extinction voltage for the 28kV class?

The corona extinction voltage for the 28kV class is 21.5kV AC at 3pC sensitivity.

How to Install K655LR/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K655LR/K675LR Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to high voltage apparatus.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductor), Hotstick, Suitable voltage sensing device, Torque wrench

Supplies needed:

K655LR/K675LR Elbow Connector, Cable Adapter, Compression Lug, Insulating Plug (if applicable), Lubricant (silicone based), Stud Prepack (if needed), Cable (appropriate type and size), Tape marker, Grounding wire (No. 14 AWG Copper or equivalent), Suitable connector (for grounding), Grounding device (if used), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Ensure Safety and Prepare Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Check package contents for completeness and ensure proper fit with cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Assemble Cable and Make Initial Cut

    Assemble the cable in its final position with enough slack to allow adequate clearance for removing the elbows. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the center line of the mating product.

  3. Clean and Prepare Cable for Termination

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Refer to the installation instructions and diagrams supplied with the product for specific cable preparation steps based on your cable type (e.g., non-jacketed, jacketed, Unishield, lead sheath). Remove the outer jacket (where applicable) and prepare the cable shield and insulation according to the specified dimensions.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor for Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is outside this range, redo the assembly.

  6. Install Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8 inches to 7-1/8 inches (162mm-181mm). If dimensions are incorrect, redo the assembly.

  7. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  8. Prepare Mating Products for Connection

    Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Keep all surfaces clean during this process. WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED.

  9. Connect Elbow to First Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect Second Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  11. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap onto the elbow and push down hard until it snaps into place. Prepare to follow the voltage test directions.

  12. Ground the Cable Shield

    Insert one end of a grounding wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with your grounding device or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Torque All Components (for 600A L-Kits)

    CAUTION: When constructing 600-amp L-Kits, ensure that each component is tightened to the specified torque according to the instructions provided with the kit.

  14. Perform Voltage Test

    To determine if the circuit is energized, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Contamination or incorrect equipment can give a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.