Authorized ABB Distributor (Installation Products)
ABB - Installation Products K650J3-4 - 15/25kV 600 Amp Series Deadbreak 3-Point Junction, Rubber Junctions only.

ABB Installation Products K650J3-4 15/25kV 600 Amp Series Deadbreak 3-Point Junction, Rubber Junctions only.

UPC: 075114370486


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K650J3-4 is a 15/25kV, 600 Amp Series Deadbreak 3-Point Junction designed for medium-voltage cable termination and interconnection. This unit features rubber junctions for electrical insulation and environmental sealing, ensuring reliable performance in power distribution systems. The deadbreak design allows safe connection and disconnection under load without interrupting service, critical for substations, industrial facilities, and utility networks. With a 600 Amp current rating, it supports substantial power flow while maintaining system integrity. The 3-point junction configuration enables efficient branching of medium-voltage circuits, reducing installation complexity. Suitable for both indoor and outdoor applications, this junction is built for durability in demanding operational conditions. The top cable access design simplifies installation and maintenance, while the 65 kAIC rating ensures fault current withstand capability. Part of ABB’s medium-voltage product line, the K650J3-4 is optimized for medium-voltage power distribution where secure, insulated connections are essential.
  • 15/25kV voltage rating for medium-voltage applications
  • 600 Amp current rating for high-power distribution
  • Series Deadbreak design enables safe load-break connections
  • Rubber junctions provide electrical insulation and environmental sealing
  • Top cable access simplifies installation and maintenance

Specifications

Application
Designed for subsurface, vault or padmount applications and can be used for sectionalizing, looping, tapping, and equipment bypass
Connection
Push-In
Connection Type
Deadbreak
Current Rating
600 A
Material
Rubber
Material
EPDM-Rubber
Poles
3-Point Junction
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provides mating for Elastimold 600 Amp Series Elbow connectors. Rubber Junction Only
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
3-Point Rubber Junction
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.

J6-622226-25

6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
3 Point Junction, three - 600 Amp Bushing interface, 15KV, with Bracket, SV - Optional 6-1/2 inch spacing. Left Parking Stand.

J3-666-15-SV-L

3 Point Junction, three - 600 Amp Bushing interface, 15KV, with Bracket, SV - Optional 6-1/2 inch spacing. Left Parking Stand.
600 Amp, 35KV, Cam-Op, Size Sensitive Kit, Cable Adapter and Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Compacted Solid 4/0.

755CK-J0260

600 Amp, 35KV, Cam-Op, Size Sensitive Kit, Cable Adapter and Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Compacted Solid 4/0.
600 Amp, 15/25KV, Cam-Op, Size Sensitive Kit, (Cable Adapter, and Lug), Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Solid Compact 250 kcmil or mmSquared 125.

655CK-K5270

600 Amp, 15/25KV, Cam-Op, Size Sensitive Kit, (Cable Adapter, and Lug), Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Solid Compact 250 kcmil or mmSquared 125.
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, Left Parking Stand.

J3-626-25-L

3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, Left Parking Stand.
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, Left Parking Stand. Tilt Mounting Adapter.

J3-626-25-L-TMA

3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, Left Parking Stand. Tilt Mounting Adapter.
900 Amp, Cable Adapter and Lug, DeadBreak, 15/25KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

675CK-J2270

900 Amp, Cable Adapter and Lug, DeadBreak, 15/25KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV, 600 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Includes Boot and Collar. SP - Stud Permanent.

K650TBC-SP

15/25kV, 600 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Includes Boot and Collar. SP - Stud Permanent.

Frequently Asked Questions

What is the K650J3 product?

The K650J3 is a 15/28kV, 600 Amp Deadbreak 3-Way Junction. It features a fully shielded, submersible molded rubber housing.

What is the momentary current rating for the K650J3?

The momentary current rating for the K650J3 junction is 25kA Sym for 10 Cycles, applicable to both 15kV and 28kV classes.

What is the BIL impulse withstand for the 15kV class?

For the 15kV voltage class, the BIL Impulse Withstand is 95kV (1.2 x 50 microsecond wave).

How do I order only the mounting bracket and back plate?

To order only the mounting bracket and back plate, add "-6" at the end of the catalog number.

How do I order the K650J3 with "U" style mounting straps?

To order the K650J3 with "U" style mounting straps only, add "-5" at the end of the catalog number.

What is included in the K650J3 kit?

Each kit contains one basic molded K650J3 junction, mounting hardware 600J3-6, two tubes of lubricant 82-08, installation instructions IS-0207, and three protective caps 650PPC-01.

What standard does the K650J3 junction meet?

The K650J3 junction meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating for the K650J3?

The continuous current rating for the K650J3 junction is 600 Amp for both 15kV and 28kV voltage classes.

What is the maximum operating voltage for the 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What is the maximum operating voltage for the 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

How to Install Deadbreak Junctions (Universal Mount)

This guide provides step-by-step instructions for installing two-, three-, and four-point deadbreak junctions using the universal mount method. It covers mounting, assembly, grounding, and initial operating procedures.

Estimated time: 1h

Tools needed:

Wrench, Screwdriver, Wire strippers

Supplies needed:

Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware (3/8" hex head cap screws, ext. tooth lock washers, 3/8" hex nuts, 1/2" hex head cap screws, 1/2" split lock washers, 1/2" hex nuts), Suitable fasteners (for mounting initial universal brackets to surface), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, Insulated caps (if applicable)

  1. Determine Mounting Location and Mark Slots

    Select the desired location for the junction assembly. Use the base plate as a template, position it on the mounting surface, and accurately mark all slot locations for drilling or fastener placement.

  2. Mount Initial Universal Brackets

    Secure two universal brackets to the marked surface using suitable fasteners. Ensure they are tightened securely to prevent any movement during operation. DANGER: Ensure the mounting surface is de-energized before proceeding.

  3. Assemble Remaining Universal Brackets

    Connect the remaining two universal brackets to the previously mounted brackets at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten all hardware securely.

  4. Assemble Deadbreak Junction to Base Assembly

    Attach the deadbreak junction to the base bracket assembly and base plate. Use the two supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts, securing them through the center mounting holes of the bracket assembly. Tighten all components securely.

  5. Mount Junction Assembly to Brackets

    Secure the assembled deadbreak junction to the universal brackets using the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Tighten all fasteners securely. Verify that the parking stand is in the upright position.

  6. Ground the Junction Assembly

    Ground the base bracket assembly and the junction's black conductive jacket. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure a secure and reliable ground connection.

  7. Prepare Operating Interfaces

    Remove all protective shipping caps from the junction. Clean each operating interface thoroughly. Apply an ELASTIMOLD approved lubricant to each interface. Do not use substitute lubricants, as they may damage the product or mating components.

  8. Install Insulated Caps on Unused Bushings

    If any operating interfaces are not utilized, install appropriate insulated caps on the unused bushings. IMPORTANT: Do not use the protective shipping caps for this purpose, as they are not insulated and are only for protection during handling and installation. Ensure all unused interfaces are properly capped before energization. DANGER: Failure to use proper insulated caps can lead to serious injury or equipment damage upon energization.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.