ABB Installation Products J3-666-15-SV-L 3 Point Junction, three - 600 Amp Bushing interface, 15KV, with Bracket, SV - Optional…
UPC: 075114371520
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Three 600 Amp bushing interfaces for high-current applications
- 15KV rated for medium-voltage power distribution
- Optional 6-1/2 inch spacing (SV configuration) for standardized clearance
- Includes mounting bracket and left-side parking stand for cable management
- Compatible with ABB Installation Products for seamless integration
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Current Rating | 600 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Tilt Mounting Bracket |
Mounting Type | Left Parking Stand |
Poles | 3 |
Series | J3 |
Size | Overall Length 21.5 inches, Width 6.75 inches |
Size | 6-1/2 inch spacing |
Special Features | 6-1/2 inch Center Spacing. Left Parking Stand |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 3 Points |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-6226-15-L
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Left Parking Stand.
655CK-K5270
600 Amp, 15/25KV, Cam-Op, Size Sensitive Kit, (Cable Adapter, and Lug), Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Solid Compact 250 kcmil or mmSquared 125.
J3-626-25-L
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, Left Parking Stand.
J3-626-25-L-TMA
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, Left Parking Stand. Tilt Mounting Adapter.
675CK-J2270
900 Amp, Cable Adapter and Lug, DeadBreak, 15/25KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K650TBC-SP
15/25kV, 600 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Includes Boot and Collar. SP - Stud Permanent.
775J3-5
900 Amp, 35kV, Deadbreak, 3-Point Junction, Rubber Junction, Stainless Steel U-straps and back plate.Frequently Asked Questions
What are the parking stand options?
Parking stand options include Left parking stand only (L), Right parking stand only (R), or No parking stand (N).
What is the maximum operating voltage for 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV.
How are different interfaces identified for ordering?
For ordering, '2' identifies a 200 Amp Deepwell Interface, '6' identifies a 600 Amp Bushing Interface, and 'B' indicates a Blank Position.
Does the junction meet industry standards?
Yes, the junction meets ANSI/IEEE Standard 386, Latest Revision.
What are the momentary and fault close ratings?
For 600 Amp, it's 25kA Sym for 10 Cycles. For 200 Amp, it's 10kA Sym for 10 Cycles.
What types of connectors are compatible?
The junction provides mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.
What is included in the basic junction kit?
Each kit contains the basic molded junction, mounting hardware, lubricant tubes, installation instructions, and a protective cap.
What is the maximum operating voltage for 35kV class?
For the 35kV class, the maximum phase-to-ground operating voltage is 21.1kV.
What is the maximum operating voltage for 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV.
What are the available interface spacing options?
The available interface spacing options are standard 4 inches spacing or optional 6.5 inches spacing.
How to Install a Deadbreak Junction with Universal Mount
This guide provides step-by-step instructions for installing a deadbreak junction using the universal mounting method. It covers mounting, assembly, grounding, and preparing for operation. Always de-energize apparatus before installation and ensure installation is performed by competent personnel.
Estimated time: 45m
Tools needed:
Wrench Set, Wire Strippers, Measuring Tape
Supplies needed:
Mounting Hardware Prepack, Surface Mounting Fasteners, Grounding Wire (No. 2 solid to 1/0 stranded), ELASTIMOLD Approved Lubricant, HV Insulated Caps (if required)
- Determine Mounting Location
Determine the desired location for the junction assembly. Place the base plate on the mounting surface as a template and mark the slot locations for drilling or fastener placement. Ensure the area is de-energized before proceeding with any installation.
- Attach First Universal Brackets
Attach two universal brackets to the marked flat surface using suitable fasteners (supplied by user). Tighten securely to ensure no movement during operation.
- Assemble Remaining Universal Brackets
Attach the remaining two universal brackets to the two brackets already mounted on the surface at the desired angle using the supplied hardware (3/8” hex head cap screw, external tooth lock washer, 3/8” hex nut). Tighten all connections securely.
- Assemble Junction to Base
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.
- Secure Junction Assembly
Attach the assembled deadbreak junction to the universal brackets using the supplied hardware (1/2” split lock washer, 1/2” hex nut, 1/2” hex head cap screw). Ensure the parking stand is in the upright position and tighten all fasteners securely.
- Ground the Junction Assembly
Ground the base bracket assembly and the junction’s black conductive jacket. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure a secure and reliable ground connection.
- Prepare for Operation
Remove all protective shipping caps and clean the operating interfaces. Lubricate each interface with an ELASTIMOLD approved lubricant; do not substitute. If any operating interfaces are not utilized, install appropriate HV insulated caps on those unused bushings before energization. Do not use protective shipping caps for this purpose.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.