Contact for Pricing
Overview
- 600 Amp current rating
- 15/25kV voltage rating
- Deadbreak connection type for safe circuit interruption
- 3 inches widest diameter
- Factory assembled, non-removable stud for secure connection
Specifications
Application | 15/25 kV, 600 Amps |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Connecting Plug |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.6900 L |
Package Weight (Metric) | 1.2200 kg |

K650RTW
15/25kV 600 Series Deadbreak Reducing Tap Well. Length 5.37 inch. Width 3 inch not counting bracket. 600/200 Amps
L1601-PC-S2R-WG
35kv, Short Shank Well without Bail Tabs and with Replaceable Well Stud (2-3/4 inch Bushing Shank Length), With Gasket
K656LINKCLRM0360BDRG
600 Amp, 25kV, Deadbreak, Cam-Op Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. With Insulated Cap, With Test Point.
K655BLR-H0240
15/25kV 600 Series Deadbreak Elbow without Test Point (with Stud), Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.Frequently Asked Questions
What is the K650CP connecting plug used for?
The K650CP connecting plug is an insulated bus used to attach and connect two or more Elastimold K655LR/K656LR 600 Amp connectors.
What are the 28kV operating voltage limits for the K650CP?
For the 28kV voltage class, the maximum operating voltage is 16.2kV phase-to-ground and 28kV phase-to-phase.
What lubricant is provided with the K650CP kit?
The K650CP kit includes one tube of lubricant, specifically 82-08.
What items are included in the K650CP kit?
Each kit contains one K650CP connecting plug, one tube of lubricant 82-08, and installation instructions IS-0230.
How can I order the K650CP with a factory-assembled stud?
To order the K650CP with a factory-assembled stud, add "SP" to the part number.
What is the impulse withstand rating for the 28kV K650CP?
For the 28kV voltage class, the K650CP has a 140kV BIL impulse withstand rating (1.2 x 50 microsecond wave).
What is the continuous current rating for the 28kV K650CP?
For the 28kV voltage class, the K650CP has a continuous current rating of 900 Amp.
What is the impulse withstand rating for the 15kV K650CP?
For the 15kV voltage class, the K650CP has a 95kV BIL impulse withstand rating (1.2 x 50 microsecond wave).
What is the continuous current rating for the 15kV K650CP?
For the 15kV voltage class, the K650CP has a continuous current rating of 600 Amp.
What are the 15kV operating voltage limits for the K650CP?
For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for installing the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures. Ensure all apparatus are de-energized before beginning installation.
Estimated time: 2h
Tools needed:
Hot stick, Suitable tool for 1 inch hex (e.g., socket wrench), Torque wrench, Wire strippers, Welding equipment (if using mounted stand-off plug), 600ATM Operating Tool
Supplies needed:
ELASTIMOLD supplied lubricant, 600 amp elbow, Cable, Stand-off plug (SOP) (if applicable), 3/8-16 x 2 inch studs (if applicable), Hex nuts, Lockwashers, Bushing extender, Alignment bracket, Bushing extender clamp, Elbow clamp, Hex bolts, #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector, Mating 200 amp product (if applicable)
- Prepare for Installation and Install 600 Amp Elbow
DANGER: Ensure all apparatus are de-energized during installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow, ensuring it will align with the stand-off plug or apparatus bushing.
- Install Mounted Stand-Off Plug (If Applicable)
If using a mounted stand-off plug, weld three 3/8-16 x 2 inch studs to the faceplate according to customer standards. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Install the stand-off plug over the studs, resting on the nuts or spacers. Secure with lockwashers and hex nuts, tightening to 12 foot-lbs torque. Verify the top surfaces of the bushing and stand-off plug are in-line.
- Install Bushing Extender and Elbow
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread into the apparatus bushing using a suitable tool on the 1 inch hex portion, torquing to 50-60 ft-lbs. Clean and lubricate the epoxy stand-off plug (if used) and both interfaces of the 600 amp elbow. Install the elbow onto the epoxy stand-off plug. Insert the 600AMT into the retainer contact, engage the internal hex broach, and thread into the epoxy stand-off plug through the compression lug hole, torquing to 50-60 ft-lbs.
- Install Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with supplied hardware, torquing by alternating sides until clamp tabs are flush and tight. Position the elbow in the alignment bracket so the elbow cuff is evenly lined up with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket, torquing by alternating sides until clamp tabs are flush and tight. Ensure the elbow clamp notch faces the cable entrance.
- Insert the Link Connector
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye to engage the roller pin and move the Link inward. Continue moving lever arms until perpendicular to the alignment bracket leg.
- Ground the System
Ground the elbow: Feed a #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twist tight, and connect to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired mating product on the 200 amp interface per its installation instructions. Ground the cable: If concentric neutral cable is used, twist the neutral wires together and connect to ground with an appropriate connector. If 20MA or 21MA grounding devices are used, connect their ground lead to ground with a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.