ABB Installation Products K151SP-B0250-S 15/25kV, 200 Amp, Deadbreak Straight Plug without Test Point, Cable Insulation Diameter…
UPC: 075114331586
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 15/25kV and 200 amperes
- Cold-shrinkable jacket seal for tool-free installation
- Accommodates cable insulation diameters 0.635 to 0.905 inches
- Supports conductor sizes 250-2/0 stranded/compressed or 3/0 solid/compact
- Deadbreak design allows safe connection/disconnection under load
Specifications
Amperage Rating | 200 A |
Application | Designed to Terminate UD Cable having Concentric Neutral and Extruded instalation shielding |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 8.81 in |
Length | 223.774 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Plug |
Voltage Rating | 15 to 25 kV |
Width | 2.55 in |
Width | 64.77 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR3B0250
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
655CETP-K0300
15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Solid Compact 400 kcmil.
655CETP-M0380-SG3
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
168ELR-7495-5270-S
15kV, 200 Amp, Loadbreak Repair Elbow with Test Point, Cable Insulation Diameter 0.740 to 1.100 inches, Bi-Metal, Conductor Size 240 - 4/0 Stranded/Compressed or 250 Solid/Compact. S - Cold-Shrinkable Jacket Seal
655CETP-H0270-DRG-S
15kV, 600 Series ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter, Lug and Insulated Cap Kit, without Test Point, with Sealing Kit. Cable Insulation Diameter Range 0.850 to 1.050 inches, Aluminum Lug, 4/0 Stranded/Compressed or 250 Solid/Compact.
K656CETPM0380DRGS
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. S - Cold Shrinkable Jacket Seal.
655CETP-L0330-DRG
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
K656CETPM2380
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.Frequently Asked Questions
What is the BIL impulse withstand for 25kV class?
For the 25kV voltage class, the BIL Impulse Withstand is 125kV (1.2 x 50 microsecond wave).
What is the BIL impulse withstand for 15kV class?
For the 15kV voltage class, the BIL Impulse Withstand is 95kV (1.2 x 50 microsecond wave).
What Elastimold products are compatible with K151SP?
The K151SP is designed to mate with Elastimold® K151T tee splice and K151SR straight receptacle products.
What is the momentary current rating of the K151SP?
The K151SP has a momentary current rating of 10kA Symmetrical for 10 Cycles for both 15kV and 25kV voltage classes.
What is the continuous current rating of the K151SP?
The K151SP has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
What is the maximum operating voltage for 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.
What is the maximum operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What conductor sizes does the K151SP accommodate?
The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded. It also supports cable insulation diameters from 0.575 inches to 1.220 inches.
What cables are compatible with the K151SP?
The K151SP is designed for UD cable with concentric neutral and extruded insulation shielding. It can also terminate other cable types with a proper Elastimold® cable shield adapter.
What type of product is the K151SP?
The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug. It features a fully shielded, fully submersible molded rubber housing.
How to Install the K151SP Straight Plug for High Voltage Cable Connections
This guide provides detailed instructions for installing the K151SP Straight Plug, including cable preparation, conductor crimping, and connection to a mating ELASTIMOLD receptacle on 15kV and 25kV class systems. Ensure all safety precautions are followed.
Estimated time: 45m
Tools needed:
Wire brush, Crimp tool, Approved solvent, Rag, Nylon rod (supplied), ELASTIMOLD bail (required)
Supplies needed:
K151SP Straight Plug, Conductor Contact (female), Lubricant (supplied), Solid dielectric type cable, Mating ELASTIMOLD receptacle, Silicone grease, Copper wire (#14 AWG or equivalent)
- Prepare for Installation and Ensure Safety
Before starting, ensure all apparatus is de-energized. Inspect all parts for damage, correct rating, and compatibility with mating products. This product must be installed only by competent personnel trained in high voltage electrical equipment safety. Read all instructions thoroughly and have required tools ready. If supplied with a protective shipping cover, remove it and replace with appropriate HV insulated cap(s) or connector(s) before energizing.
- Prepare Cable Jacket and Shield
For Jacketed Concentric Neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient concentric neutral wires for grounding. For Copper Tape Shield cable, cut and remove the cable jacket 7-1/2 inches from the end, then remove the copper tape shield 6-1/2 inches from the end of the cable. Follow specific instructions for ECS or MA grounding devices if used.
- Prepare Conductor and Crimp Terminal
Remove 7/8 to 1 inch of cable insulation and conductive shield (1-3/4 to 1-7/8 inches for #1 stranded/compr. and #1/0 compt./solid aluminum cable). Cut squarely, do not pencil. Wire brush bare aluminum conductors immediately and insert into the crimp barrel containing inhibitor. Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Start crimps at the crimp line and rotate each successive crimp 90 degrees. Carefully wipe excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Clean Insulation
Temporarily remove the plastic pin. Remove the semi-conductive shield 7-3/4 to 7-13/16 inches back from the end of the socket with a straight, smooth, squared cut, ensuring not to cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the cable end toward the outer jacket to remove all semi-conducting residue. Install an ECS or MA grounding device if applicable.
- Lubricate Cable and Position Collar
Slide the collar, smaller end first, onto the cable. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown in the diagram and to the inside of the housing. Do not substitute lubricants, as others may harm the product or its mating part.
- Install Plug onto Cable
Push the cable into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.
- Connect to Mating Receptacle
Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection using an ELASTIMOLD bail, referencing the Bailing Instruction Sheet (150TB-4).
- Connect Grounding Device
If an ELASTIMOLD grounding device is not being used, connect a length of customer-supplied #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.