ABB Installation Products J5-22666-15 5 Point Junction, with two 200 Amp Bushing Well Interfaces and three 600 Amp Bushing…
UPC: 783786401222
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 5-Point Junction configuration
- Two 200 Amp Bushing Well Interfaces
- Three 600 Amp Bushing Well Interfaces
- 15kV Voltage Rating
- No Tilt Mounting
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Current Rating | 200 A, 600 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Tilt Mounting Bracket |
Mounting Type | No Tilt Mounting |
Poles | 5 |
Series | J5-22666-15 |
Size | Overall Length 23 inches, Width 6-3/4 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 5 Points |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-6226-15-L
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Left Parking Stand.
J6-622226-15-TMA
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 15kV, Tilt Mounting Adapter.
J5-22266-25
5 Point Junction, with three 200 Amp Bushing Well Interfaces and two 600 Amp Bushing Interfaces, 25kV, No Tilt Mounting.
J2-66-35-SV
2 Point Junction, with two 600 Amp Bushing Interfaces, 35kV, 6-1/2 inch centers. No Tilt Mounting.Frequently Asked Questions
What are the voltage classes for this product?
The product is available in 15kV, 25kV, and 35kV voltage classes, meeting ANSI/IEEE Standard 386.
What is the maximum operating voltage for the 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What is the rule for mixing 200 Amp and 600 Amp interfaces?
When mixing 200 Amp and 600 Series interfaces on a junction, always start with the 200 Amp side.
How are 200 Amp and 600 Amp interfaces identified?
A '2' identifies a 200 Amp Deepwell Interface, and a '6' identifies a 600 Amp Bushing Interface in the catalog number.
What items are included in a junction kit?
Each kit contains a basic molded junction, mounting hardware, two tubes of lubricant, installation instructions, and a protective cap.
What is the maximum operating voltage for the 35kV class?
For the 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.
What is the maximum operating voltage for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What are the available interface spacing options?
The units offer a standard 4 in spacing or an optional 6.5 in spacing for interfaces.
What connectors are compatible with the junctions?
The junctions provide mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.
What applications are suitable for these junctions?
ELASTIMOLD junctions are designed for subsurface, vault, or padmount applications. They can be used for sectionalizing, looping, tapping, and equipment bypass.
How to Install the J5-22666-15 Deadbreak Junction (Universal Mount)
This guide provides step-by-step instructions for installing the J5-22666-15 two-, three-, or four-point deadbreak junction using the universal mount method. It covers mounting, assembly, and grounding procedures for sectionalizing, looping, or tapping electrical systems.
Estimated time: 1h
Tools needed:
Wrenches, Marker, Wire strippers, Screwdriver
Supplies needed:
J5-22666-15 Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack, Suitable fasteners (user supplied), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricants, HV insulated caps or connectors
- De-energize Apparatus and Determine Location
DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Determine the desired mounting location for the junction assembly. Use the base plate as a template, place it on the mounting surface, and accurately mark all slot locations for subsequent bracket attachment.
- Attach Initial Universal Brackets
Attach two universal brackets to the marked surface using suitable fasteners. Tighten them securely to prevent any movement during operation.
- Attach Remaining Universal Brackets
Connect the remaining two universal brackets to the two brackets already mounted on the surface, positioning them at the desired angle. Use the supplied 3/8” hex head cap screws, external tooth lock washers, and hex nuts, then tighten securely.
- Assemble Junction to Base Bracket and Base Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Secure them using two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts through the center mounting holes of the bracket assembly. Tighten all hardware securely.
- Attach Junction Assembly to Universal Brackets
Attach the complete deadbreak junction assembly to the previously mounted universal brackets using the supplied 1/2” hex head cap screws, split lock washers, and hex nuts. Ensure the parking stand is in the upright position before tightening all fasteners securely.
- Ground the Assembly
Ground the base bracket assembly and the junction's black conductive jacket. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket and ensure a secure, low-resistance connection to earth ground.
- Prepare for Operation
Before energizing, remove all protective shipping caps and thoroughly clean the operating interfaces. Lubricate each interface with an ELASTIMOLD approved lubricant; do not use substitutes. If any operating interfaces are not utilized, install appropriate HV insulated caps on the unused bushings. Never use protective shipping caps for this purpose as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.