ABB Installation Products J4-2222-15 4 Point Junction, with four 200 Amp Bushing Well Interfaces, 15kV, No Tilt Mounting.
UPC: 783786394302
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 4-point molded multipoint junction for medium-voltage applications
- Four 200 Amp bushing well interfaces for reliable power distribution
- 15kV voltage class with 8.3kV max phase-to-ground operating voltage
- Fully shielded, submersible molded rubber housing with EPDM insulation
- No tilt mounting design for stable, stress-free installation
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Tilt Mounting Bracket |
Size | Overall Length 23 inches, Width 6-3/4 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 4 Points |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 19.9700 L |
Package Weight (Metric) | 9.0580 kg |

J6-622226-25
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
J3-626-25
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
J6-222226-15-TMA
6 Point Junction, with five 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 15kV, Tilt Mounting Adapter.
J6222226-15
6 Point Junction, with five 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 15kV, No Tilt Mounting.
J2-66-15-SV
2 Point Junction, with two 600 Amp Bushing Interfaces, 15kV, 6-1/2 inch centers. No Tilt Mounting.
J5-22666-15
5 Point Junction, with two 200 Amp Bushing Well Interfaces and three 600 Amp Bushing Interfaces, 15kV, No Tilt Mounting.Frequently Asked Questions
What are the voltage classes for these junctions?
The multipoint junctions are available in 15kV, 25kV, and 35kV voltage classes.
What is the operating voltage for a 25kV class junction?
The maximum phase-to-ground operating voltage for a 25kV class junction is 16.2kV.
What is the operating voltage for a 15kV class junction?
The maximum phase-to-ground operating voltage for a 15kV class junction is 8.3kV.
What is included in each junction kit?
Each kit contains the basic molded junction, mounting hardware, lubricant tubes, installation instructions, and a protective cap.
What are the available interface spacing options?
The junctions are available with standard 4'' spacing or optional 6.5'' spacing.
What connectors are compatible with these junctions?
The junctions provide mating for both 600 Amp and 200 Amp Elastimold Elbow connectors.
What materials are used for the housing and brackets?
The housing is molded rubber with peroxide-cured EPDM, and brackets use 304 stainless steel for corrosion prevention.
What applications are these junctions designed for?
They are designed for subsurface, vault, or padmount applications, used for sectionalizing, looping, tapping, and equipment bypass.
What are the momentary current ratings?
For 600 Amp, it's 25kA Sym for 10 cycles; for 200 Amp, it's 10kA Sym for 10 cycles.
What are the continuous current ratings?
The junctions are rated for 600 Amp continuous or 200 Amp continuous.
How to Install a J4 Deadbreak Junction with Universal Mount
This guide details the installation of a J4 Deadbreak Junction using the universal mounting method, including securing brackets, assembling the junction, and proper grounding procedures. Ensure all apparatus is de-energized before beginning.
Estimated time: 1h
Tools needed:
Wrench set (for 3/8 inch and 1/2 inch hex nuts/screws), Marking tool, Wire strippers, Crimping tool (optional, for grounding wire), Multimeter (for safety verification)
Supplies needed:
J4 Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (supplied with junction), Suitable fasteners (for mounting brackets to surface, user-supplied), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (for unused interfaces)
- De-energize and Inspect Apparatus
DANGER: All apparatus must be de-energized during installation or removal of parts. Verify the circuit is de-energized using appropriate safety procedures. Inspect all parts for damage, correct rating, and compatibility with mating parts before proceeding with installation.
- Determine Location and Mark Mounting Slots
Determine the desired location for the junction assembly on a flat surface. Use the base plate as a template, place it on the mounting surface, and accurately mark all slot locations for the universal brackets.
- Attach Initial Universal Brackets to Surface
Attach two (2) universal brackets to the marked flat surface using suitable fasteners (user-supplied). Tighten these fasteners securely to prevent any movement of the brackets during operation.
- Attach Remaining Universal Brackets
Attach the remaining two (2) universal brackets to the two (2) universal brackets already mounted on the surface. Position them at the desired angle using the supplied 3/8 inch hex head cap screws, external tooth lock washers, and 3/8 inch hex nuts. Tighten securely.
- Assemble Junction to Base Bracket and Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Use two (2) supplied 1/2 inch hex head cap screws, two (2) 1/2 inch split lock washers, and two (2) 1/2 inch hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten all components securely.
- Attach Junction Assembly to Universal Brackets
Attach the complete deadbreak junction assembly to the universal brackets using the supplied 1/2 inch split lock washers, 1/2 inch hex nuts, and 1/2 inch hex head cap screws. Ensure the parking stand is in the upright position and tighten all hardware securely.
- Ground the Assembly
The base bracket assembly and the junction’s black conductive jacket must be properly grounded. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket for this purpose. Ensure a secure and reliable ground connection.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces and thoroughly clean them. Lubricate each interface with an ELASTIMOLD approved lubricant. DO NOT substitute with other lubricants, as they may harm the product or its mating components.
- Install Insulated Caps on Unused Interfaces
If any operating interfaces are not utilized, install appropriate HV insulated caps on these unused bushings before energizing the circuit. Do not use the protective shipping caps for this function, as they are not insulated and are only intended for handling and installation.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.