Overview
- Flood-Seal design for outdoor environmental protection
- Mechanical compression connection for secure, low-resistance electrical interface
- Supports main conductor range: 14 AWG to 2 AWG
- Supports tap conductor range: 14 AWG to 6 AWG
- Y-Line mechanical run compression kit for fused applications
Specifications
Amperage Rating | 30 A |
Application | Rated 600V, 30 Amps Maximum, perfect for heavy-duty applications |
Color | Black |
Conductor Range | Main #14 to #2 AWG , Tap #4 to #6 AWG |
Connection | Mechanical |
Environmental Conditions | WaterTight |
Insulation | True |
Material | Aluminum and Copper, EPDM-Rubber Housing |
Number of Conductors | 3 |
Special Features | EPDM Flood-Seal Housing ensures a fully insulated, watertight, and submersible connection. Beakaway design separates under tension so wires don't break. Safe separations to ensure fuse or connecting link stays in load side when separated. Re-Enteralbe to enable sectionalizing. Matching Ampacit Rating - run or feeder lugs have the same ampacity rating as the cable, up to 2/0. Y-Ype Mechanical Run Compression Taps use a 1/8 nich Hex wrench for easy Installation |
Type | Break-Away Streetlight Kits |
Voltage Rating | 600V |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.3400 L |
Package Weight (Metric) | 0.1540 kg |

DYC 1
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, non-fused, wire size stranded 1 copper run ,copper tap fused, installing dies 3/8,11K,TB,37
VFN-021-00
Solenoid Valve Connectors, Field Wireable, 3 Pole, Form A 18mm, 250V, 10A, PG11 opening, gray housing
DYU 6
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits - Y Line mechanical run Compression Kits, non-fused, conductor range main 14-2 tap 14-6
DYU 2
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits - Y Line mechanical run Compression Kits, non-fused, conductor range main 14-2 tap 4-2
DST 402
Anti-Rotational Hot Line Stirrups - crank-type, ACSR 3/0-4/0, Stranded 3/0-4/0, width (A) 10, bail 2, length (C) 2-3/4, die D.
NST 60010
Anti-Rotational Hot Line Stirrups - crank-type, ACSR 397.5 (26/7) - 556.5 (18/1), Stranded 477-600, width (A) 12, bail 1/0, length (C) 2-7/8, die N.
NB 50040 ST
Anti-Rotational Hot Line Stirrups - crank-type, ACSR 4/0-477 (18/1), Stranded 4/0-500, width (A) 10, bail 2/0, length (C) 2-7/8, die N.How to Assemble the FYU Street Lighting Kit
This guide provides step-by-step instructions for assembling and wiring the FYU street lighting kit, including cable preparation, component integration, and final connections. Installation must be performed by a qualified electrician in accordance with national and local electrical codes, ensuring power is disconnected and LINE/LOAD sides are identified.
Estimated time: 1h
Tools needed:
Crimping tool, Appropriate crimping dies, 1/8 inch hex wrench, Wood dowel, Wire strippers, Multimeter
Supplies needed:
Y-Type housing, Load side (Plug) housing, Line end insert, Fuse holder, Fuse (13/32" x 1 1/2", 600V 30A max) or Connecting link, Electrical cable, Lubricant
- Prepare Load Side Housing
Measure the cable diameter and refer to Table 1 in the documentation to select the corresponding section on the load side (plug) housing. Cut off any remaining sections of the housing to match the size referenced in the "Range" column of Table 1 for your cable's outer diameter.
- Strip Load Side Cable Insulation
Thoroughly clean approximately 8 inches along the load side cable end. Apply lubricant and insert the cable through the small hole in the load side (plug) housing. Push the cable through a sufficient distance to allow for 3/8 inch of insulation stripping. Strip the insulation a distance of 3/8 inch from the end of the cable.
- Crimp Cable to Fuse Holder
Insert the stripped load side cable into the crimp barrel of the fuse holder. Using the appropriate crimping tool and die as suggested in Table 2 of the documentation for your conductor size, securely crimp the cable to the fuse holder.
- Secure Fuse Holder to Load Side Housing
Lightly apply lubricant to the outside of the fuse holder. Insert the wood dowel into the fuse holder socket and brace the free end of the dowel against a firm surface. Push the load side (plug) housing forward until the fuse holder snaps securely into its position. Wipe off any excess lubricant.
- Install Fuse or Connecting Link
Insert a 13/32 inch by 1 1/2 inch fuse (600 Volt, 30 Amp maximum) or a connecting link (if applicable) into the load side (plug) housing. WARNING: Do NOT use a glass body fuse.
- Prepare Y-Type Housing and Cable
For the run connection, select and cut the correct cut-off ring on the Y-Type housing according to the cable being used. Cut and bevel the cable insulation. Apply lubricant to the end of the cable and the cut opening of the housing. Slide the cable through until it extends 2 to 3 inches beyond the housing. Strip the insulation 3/8 to 1/2 inch from the end of the cable. CAUTION: Do not over strip the cable.
- Connect Cables to Y-Type Housing
Insert the prepared cables into the Y-Type housing as illustrated in the documentation. Using a 1/8 inch hex wrench, tighten the connections to a minimum torque of 30 in/lbs.
- Integrate Line End Insert
Apply lubricant to the line end insert as shown in the diagram. Slide the Y-Type housing up to the bottom of the line end insert. Push the line end insert into the opening of the Y-Type housing. While pulling on the cables and holding the Y-Type housing, slide the housing towards the line end insert. Push the line end insert until it is fully seated within the housing.
- Connect Load Side to Line End
Lubricate both the male and female components of the load side (plug) housing and the line end insert. Carefully insert the load side (plug) housing, which contains the installed fuse or connecting link, into the line end insert until fully engaged.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.