ABB Installation Products DYU 2 Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits - Y Line…
UPC: 783786717750
Documents & Media
Contact for Pricing
Minimum Qty: 50
Multiplier: 50
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Non-fused Y Line mechanical run compression kit for outdoor lighting
- Main conductor range: 14-2 AWG, tap conductor range: 4-2 AWG
- Flood-Seal design for IP-rated moisture and environmental protection
- Gas-tight compression connection reduces oxidation and corrosion risk
- Quick installation without specialized tools for reduced labor costs
Specifications
Amperage Rating | 30 A |
Application | Rated 600V, 30 Amps Maximum, perfect for heavy-duty applications |
Color | Black |
Conductor Range | Main #14 to #2 AWG , Tap #4 to #2 AWG |
Connection | Mechanical |
Environmental Conditions | WaterTight |
Insulation | True |
Material | Aluminum and Copper, EPDM-Rubber Housing |
Number of Conductors | 3 |
Special Features | EPDM Flood-Seal Housing ensures a fully insulated, watertight, and submersible connection. Beakaway design separates under tension so wires don't break. Safe separations to ensure fuse or connecting link stays in load side when separated. Re-Enteralbe to enable sectionalizing. Matching Ampacit Rating - run or feeder lugs have the same ampacity rating as the cable, up to 2/0. Y-Ype Mechanical Run Compression Taps use a 1/8 nich Hex wrench for easy Installation |
Type | Break-Away Streetlight Kits |
Voltage Rating | 600V |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.3800 L |
Package Weight (Metric) | 0.1720 kg |

DYC 6
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, non-fused, wire size stranded 6 ,copper run, copper tap fused, installing dies J,7,TE,24
VFN-021-00
Solenoid Valve Connectors, Field Wireable, 3 Pole, Form A 18mm, 250V, 10A, PG11 opening, gray housing
DST 402
Anti-Rotational Hot Line Stirrups - crank-type, ACSR 3/0-4/0, Stranded 3/0-4/0, width (A) 10, bail 2, length (C) 2-3/4, die D.
NST 60010
Anti-Rotational Hot Line Stirrups - crank-type, ACSR 397.5 (26/7) - 556.5 (18/1), Stranded 477-600, width (A) 12, bail 1/0, length (C) 2-7/8, die N.
OST 42
Anti-Rotational Hot Line Stirrups - crank-type, ACSR 4, Stranded 4, Solid 6, width (A) 10, bail 2, length (C) 2-3/4, die O.
OST 22
Anti-Rotational Hot Line Stirrups - crank-type, ACSR 4-2, Stranded 4-2, width (A) 10, bail 2, length (C) 2-3/4, die O.
FYU-M
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits - Y Type Disconnect Kit, fused, conductor range main 14-2 tap 12-4How to Install the DYU Street Lighting Kit
This guide provides step-by-step instructions for assembling and installing the DYU Y-Type street lighting kit, including cable preparation, fuse holder assembly, and housing connections. WARNING: Risk of shock, disconnect power before installation. This product must be installed by a qualified electrician in accordance with national and local electrical codes. Identify LINE and LOAD sides of wiring and molded connector bodies before beginning installation.
Estimated time: 1h
Tools needed:
Crimping tool, 1/8 inch hex wrench, Wood dowel
Supplies needed:
Y-Type housing, Load side (Plug) housing, Line end insert, Fuse holder, Connecting link (DYU only), Fuse (13/32 inch by 1 1/2 inch, 600V 30A max), Lubricant, Cable
- Prepare Load Side Housing for Cable
Measure the cable diameter and refer to Table 1 (not provided in this context, but implied by original document) to select the corresponding section on the load side (plug) housing. Cut off the remaining sections of the housing to match the size referenced in the Range column of Table 1.
- Clean and Strip Load Side Cable
Thoroughly clean approximately 8 inches along the load side cable end. Apply lubricant and insert the cable through the small hole in the load side (plug) housing. Push the cable through a sufficient distance to permit 3/8 inch for stripping of insulation. Strip the insulation a distance of 3/8 inch.
- Crimp Fuse Holder
Insert the stripped cable into the crimp barrel of the fuse holder. Crimp the connection securely. Refer to Table 2 (not provided in this context, but implied by original document) for suggested crimping tools and dies based on conductor size.
- Secure Fuse Holder
Apply lubricant lightly to the outside of the fuse holder. Place the wood dowel into the fuse holder socket and position the free end of the dowel against a firm surface. Push the load side (plug) housing forward until the fuse holder snaps into position. Wipe off any excess lubricant.
- Install Fuse or Link
Insert a 13/32 inch by 1 1/2 inch fuse (600 Volt 30 Amp maximum) or the connecting link into the load side (plug) housing. WARNING: DO NOT use a glass body fuse.
- Prepare Y-Type Housing and Line Cable (Run Connection)
For a run connection, select and cut the correct cut-off ring on the Y-Type housing for the cable being used. Cut and bevel the cable insulation. Apply lubricant to the end of the cable and the cut opening of the housing. Slide the cable through until it extends 2 to 3 inches beyond the housing. Strip the insulation 3/8 to 1/2 inch. CAUTION: Do not over strip.
- Tighten Cable Connections
Insert the cables into the Y-Type housing as shown in the diagram (not provided in this context, but implied by original document). Tighten the connections to a minimum of 30 in/lbs using a 1/8 inch hex wrench.
- Assemble Line End Insert
Apply lubricant to the line end insert. Slide the Y-Type housing up to the bottom of the line end insert. Push the line end insert into the opening of the Y-Type housing. While pulling on the cables and holding the Y-Type housing, slide the housing toward the line end insert. Push the line end insert until it is fully seated in the housing.
- Final Connection
Lubricate both the male and female components. Insert the load side (plug) housing, which contains the installed link or fuse clip, into the line end insert.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.