Authorized ABB Distributor (Installation Products)
ABB - Installation Products FTH 33-175-30 - Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors - horizontal cable leads, height 11-7/8 inch stud size 3 in, outlets 6

ABB Installation Products FTH 33-175-30 Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors…

UPC: 783786726509


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 3

Multiplier: 3

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors (SKU: FTH 33-175-30) provide reliable, high-capacity electrical connections in transformer and network protection applications. Designed for horizontal cable leads, this connector features an 11-7/8 inch height and a 3-inch stud size, with 6 outlets for multi-point distribution. The clamp-on style ensures secure, vibration-resistant terminations without soldering or crimping, reducing installation time and labor costs. Ideal for utility substations, industrial power distribution, and commercial electrical systems where reliable fault protection and load management are critical. The Flood-Seal design offers ingress protection against moisture and contaminants, extending service life in harsh environments. ABB Installation Products delivers engineered solutions for power infrastructure, ensuring long-term reliability and operational efficiency.
  • Clamp-on style for secure, vibration-resistant connections
  • 11-7/8" height, 3" stud size, 6 outlets for multi-point distribution
  • Horizontal cable leads for simplified installation
  • Flood-Seal design resists moisture and contaminants

Specifications

Application
Convenient multi-tap connections to power transformers and network protectors
Conductor Range
up to 1000 kcmil
Connection
Mechanical
Insulation
PVC
Material
Aluminum Connector
Number of Conductors
6
Size
11-7/8 inch
Special Features
Horizontal Cable Leads. Compact design conserves vault and manhole space and often eliminates the need for auxiliary buses. Clamp Style base provides 3-1/4 inch of stud contact and eliminates the need for a jam nut. Rubber gasket ensures closure between connector halves
Type
Horizontal Clamp-On Style Connector
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
15.2500 L
Package Weight (Metric)
6.9170 kg
Tin Plated 175 Series Clamp-On Style Transformer and Network Protection Connectors - vertical cable leads, stud size 1/2 inch, outlets 10, with Complete Assembly with Insulating Rockets

FTT 55-175-15 TNAWR

Tin Plated 175 Series Clamp-On Style Transformer and Network Protection Connectors - vertical cable leads, stud size 1/2 inch, outlets 10, with Complete Assembly with Insulating Rockets
Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors - horizontal cable leads, height 14-3/8 inch stud size 1-1/2 in, outlets 8

FTH 44-175-15

Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors - horizontal cable leads, height 14-3/8 inch stud size 1-1/2 in, outlets 8
Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors - horizontal cable leads, height 14-3/8 inch stud size 3 in, outlets 8

FTH 44-175-30

Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors - horizontal cable leads, height 14-3/8 inch stud size 3 in, outlets 8
Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors - horizontal cable leads, height 16-7/8 inch stud size 3 in, outlets 10

FTH 55-175-30

Flood-Seal 175 Series Clamp-On Style Transformer and Network Protection Connectors - horizontal cable leads, height 16-7/8 inch stud size 3 in, outlets 10
Aluminum Flood-Seal 95 Series Screw-on Transformer Connectors- with disconnectable bushing, adapter length 10 inch, stud size 1, outlets 6

FTU 95-6-1

Aluminum Flood-Seal 95 Series Screw-on Transformer Connectors- with disconnectable bushing, adapter length 10 inch, stud size 1, outlets 6
Aluminum Compression Lug Heat-Shrink Kit, Containing (1) Aluminum Lug 250 Stranded - Compressed, Installing Dies TX, 76, 249, 840, 11A, with one 13/32 inch diameter hole on 3/4 inch pad, Lug is 2-7/16 inch Long. (1) Screw, (1) Heat Shrink Tubing. Also includes Instruction Sheet. Dual Rated for Aluminum and Copper Conductors

CFK 250 HS

Aluminum Compression Lug Heat-Shrink Kit, Containing (1) Aluminum Lug 250 Stranded - Compressed, Installing Dies TX, 76, 249, 840, 11A, with one 13/32 inch diameter hole on 3/4 inch pad, Lug is 2-7/16 inch Long. (1) Screw, (1) Heat Shrink Tubing. Also includes Instruction Sheet. Dual Rated for Aluminum and Copper Conductors
Aluminum Transformer Spade Connectors - ZBT Series - Double Row Mounting Holes, cable range 12-350, mounting holes 8 outlets 12. 4-7/8 inch X 2-7/32 inch X 6-1/2 inch

ZBT 6063

Aluminum Transformer Spade Connectors - ZBT Series - Double Row Mounting Holes, cable range 12-350, mounting holes 8 outlets 12. 4-7/8 inch X 2-7/32 inch X 6-1/2 inch
Brass Tin-Plated Threaded Transformer Stud Adapter for NEMA pad-style connections - Six-hole transformer stud adapter, Silver Brazed Stud - Size 5/8-11 UNC-2B with .875 inch Outside Diameter. Pad 7.5 inch long x 3.375 inch wide x .25 inch thick. Two rows of 3 holes spaced 1.75 inch on center and .562 inch Diameter.

2042-4

Brass Tin-Plated Threaded Transformer Stud Adapter for NEMA pad-style connections - Six-hole transformer stud adapter, Silver Brazed Stud - Size 5/8-11 UNC-2B with .875 inch Outside Diameter. Pad 7.5 inch long x 3.375 inch wide x .25 inch thick. Two rows of 3 holes spaced 1.75 inch on center and .562 inch Diameter.

How to Install FTH Split Base Series Connectors

This guide provides step-by-step instructions for the proper installation and torquing of FTH 1-1/2” and 3” Split Base Series connectors. Installation must be performed by trained installers in accordance with all applicable local, state, and national electrical codes, installation standards, and safety rules to prevent electric shock.

Estimated time: 1h

Tools needed:

Torque wrench, Socket wrench

Supplies needed:

FS 1175 Flood Seal Covers, FTH Split Base Series Connector, 1/2-13 Connector Mounting Hardware, 1/2-13 Socket Head Cap Screws, Cables

  1. Install Flood Seal Covers on Cables

    Install the FS 1175 “FLOOD SEAL”® covers onto the cables prior to crimping the connectors. This ensures they are in place for later sealing.

  2. Remove Rubber Pull Tab Plugs

    Carefully remove the rubber pull tab plugs from the connector assembly.

  3. Loosen Stud Mounting Bolts

    Loosen the stud mounting bolts and open the connector as far as possible without completely disengaging the threads.

  4. Place Connector Over Stud

    Place the connector over the 3”-12 UN transformer stud to achieve maximum thread engagement. Exercise caution to avoid damaging the stud threads during this process.

  5. Engage First Connector Half

    Push the connector half that contains the mounting bolt threads onto the stud threads. Ensure full thread engagement before proceeding.

  6. Engage Second Connector Half and Snug Bolts

    Push the other connector half onto the stud threads. Lightly snug the stud mounting bolts, following the torque sequence shown in Figure 2 of the documentation.

  7. Verify Thread Engagement and Gasket Alignment

    Before proceeding with further torquing, carefully check that the threads are fully engaged and that the split base gasket is properly aligned.

  8. Position and Initial Torque Connector

    Rotate the connector to its approximate final position. Torque the stud mounting bolts to 150 IN/LB, adhering to the sequence illustrated in Figure 2.

  9. Install Connectors to NEMA Pads

    Install the connectors to the NEMA pads using the supplied 1/2-13 bolts. Snug these bolts lightly.

  10. Adjust Connector Position

    As cables are installed into the connector, make any necessary adjustments to the connector's position to ensure proper fit and alignment.

  11. Final Torque Stud Mounting Bolts

    After all cables are installed and snugged, resume torquing the stud mounting bolts. First, torque them to 250 IN/LB, and then to 360 IN/LB, always following the sequence shown in Figure 2.

  12. Recheck Stud Mounting Bolt Torque

    Once the final torque is applied, recheck the torque of each stud mounting bolt in the specified sequence to ensure consistent and secure fastening.

  13. Final Torque Connector Mounting Bolts and Seal Connections

    Finish torquing the connector mounting bolts to 480 IN/LB (40 FT/LB). Then, slide the pre-installed FS 1175 Flood Seals onto the FTH 175 to completely seal each connection.

  14. Reinstall Rubber Pull Tab Plugs

    Reinstall the rubber pull tab plugs into their original positions to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.