ABB Installation Products FPT4-8C-C Poke-Through Base Unit, Length 19 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch…
UPC: 785991042948
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Galvanized steel construction for durability
- Features 8 communications receptacles
- 19 inches length, 7-1/2 inches diameter
- 1/2 inch hub size for easy installation
- City of Chicago Approved for safety and compliance
Specifications
Application | Flush service-City of Chicago approved |
Knockouts | True |
Material | Die Cast Zinc/Galvanized Steel |
Special Features | Full access to communications compartment through the cover without exposing power compartments even after it is installed in the floor |
Standard | UL E2969 |
Standard | UL E2969 / UL E2969 |
Type | Poke Through Systems |
Package Dimensions (L x W x H) | 6.25 IN x 5.87 IN x 5.62 IN |
Package Dimensions (L x W x H) | 15.875 cm x 14.9098 cm x 14.2748 cm |
Package Weight (Imperial) | 4.630 L |
Package Weight (Metric) | 2.100 kg |

FFPT4-BLK
Poke-Through Furniture Feed Base Unit, 4 Inch Drill Size, 18 Inch Length, Hub Size 3/4 Inch and 1-1/4 Inch, Galvanized Steel, with Black Powder Coat Cover with 7-1/4 Inch Diameter
FPT4-1TL32-2C
Poke Through Base Unit, Length 19-3/4 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 30A/250V Locking Receptacle, 2 Communications Receptacles
FPT4-4P-4C-C
Poke-Through Base Unit, 4 Inch Drill Size, 19 Inch Length, Hub Size 1/2 Inch and 1 Inch, Galvanized Steel, with 4 20A Power Receptacles and 4 Cat-5e Data Jacks with Device Plates, City of Chicago Approved
FPT4-2P-6C
Poke-Through Base Unit, Length 19 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 2 20A Power Receptacles, 6 Communications Receptacles
FPT4-4P-4C
Poke-Through Base Unit, 4 Inch Drill Size, 19 Inch Length, Hub Size 1/2 Inch and 1 Inch, Galvanized Steel, with 4 20A Power Receptacles and 4 Cat-5e Data Jacks with Device Plates
FPT4-8C
Poke-Through Base Unit, Length 19 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 8 Communications ReceptaclesFrequently Asked Questions
What is the core drill size for FFPT4?
The core drill size for the FFPT4 series is 4 inches.
What are the conduit hub sizes for FFPT4?
The FFPT4 series has a 3/4 inch hub for power and a 1 1/4 inch hub for communications.
What materials are used in FFPT4 construction?
The FFPT4 series features solid brass or aluminum covers and a base made of die-cast zinc and galvanized steel.
What safety features does the FFPT4 include?
The FFPT4 includes solid brass or aluminum covers to protect devices from damage and a patented latching lid for easy access.
How many knockouts does the junction box have?
The junction box features (5) 1/2 inch and (5) 3/4 inch knockouts, providing a total capacity of 27 cubic inches.
What finishes are available for the FFPT4 covers?
The FFPT4 covers are available in brushed brass, brushed aluminum, and black powder-coat finishes.
What is the maximum capacity of the FFPT4?
The FFPT4 can accommodate configurations such as 4 power receptacles and 4 communications devices.
What is the installation spacing requirement?
The minimum installation spacing is 2 feet on center, with no more than one poke-through per 65 sq. ft. of floor area.
Can the FFPT4 be used for isolated ground wiring?
Yes, the 20 A receptacles in the FFPT4 can be wired as isolated ground, with orange labels provided.
What types of communications devices are compatible?
The FFPT4 accepts keystone communications device plates from various manufacturers, including Extron® MAAP plates.
How to Install the FPT4-8C-C Poke-Through
Installation guide for mounting and wiring the FPT4-8C-C poke-through fitting.
Estimated time: 45m
Tools needed:
Drill, Core drill bit (4-inch diameter), Screwdriver, Wire strippers, Pliers
Supplies needed:
Thomas & Betts FPT4 series cover, Conduit fittings (if applicable), Electrical tape, Wire connectors, EMT compression fitting (for City of Chicago), Chicago Approved Junction Box (for City of Chicago)
- Determine Layout and Location
Plan the placement of the poke-through, ensuring it is at least 24 inches from other devices and at least 4-1/4 inches from any wall or pillar. Refer to spacing note 5 under "Important Notes Section".
- Drill Hole in Floor
If applicable, cut through the finished floor covering (carpet, wood, tile, linoleum) using the template provided with the cover instructions. Core drill a 4-inch diameter hole in the concrete floor. The actual hole size may be up to 4-1/16 inches.
- Assemble Base Unit
Verify the orientation of receptacles and communication outlets. Insert the base unit into the drilled hole and push down until the temporary cover screws contact the concrete floor. If flexible conduit is used, electrical connections may be made before inserting the base unit, except for City of Chicago installations.
- Assemble Cover
Remove the temporary cover. Install the FPT4 series cover according to the instructions provided with the cover. Once the cover is screwed to the poke-through, close the lid and step on the cover to fully seat it to the floor.
- Make Electrical Connections
WARNING: Ensure power is OFF before making any electrical connections. Remove the cover from the junction box. Attach conduit and make wiring connections as required by national and local electrical codes. Connect receptacle conductor leads to the branch circuit conductors according to the wiring diagram. Ensure the ground screw in the junction box is connected to the system ground. For City of Chicago installations, use an EMT compression fitting and a Chicago Approved Junction Box, and make electrical connections after the poke-through is installed and the cover is on.
- Apply Isolated Ground Labels (If Applicable)
If the circuit is connected to an isolated ground, apply the IG label (orange triangle) on the side of the receptacle as shown in the diagram. Refer to NEC 250-146 (D).
- Connect Communication Cables
Install communication cables and jacks after the cover is installed. For City of Chicago installations, remove the bottom communication hub to route the cable into the conduit, then re-attach the hub. The hub provides a threaded NPS connection for EMT conduit.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.