- Durable galvanized steel construction for corrosion resistance
- 19-3/4 inch length and 7-1/2 inch diameter for ample space
- 1/2 inch hub size for secure conduit or cable entry
- Integrated 20A/125V locking receptacle for reliable power
- Two additional communication receptacles for data connectivity
Specifications
Application | For above-grade, fire rated concrete floors |
Knockouts | True |
Material | Die Cast Zinc/Galvanized Steel |
Special Features | Four modular configurations for power receptacles and communications jacks mounted flush with the floor |
Standard | UL E2969 |
Standard | UL E2969 / UL E2969 |
Type | Poke Through Systems |
Package Dimensions (L x W x H) | 21.38 IN x 8.13 IN x 5.5 IN |
Package Dimensions (L x W x H) | 54.3052 cm x 20.6502 cm x 13.97 cm |
Package Weight (Imperial) | 9.910 L |
Package Weight (Metric) | 4.495 kg |

FPT4-1TL31-2C
Poke Through Base Unit, Length 19-3/4 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 30A/125V Locking Receptacle, 2 Communications Receptacles
FPT4-1TL22-2C-C
Poke Through Base Unit, Length 19-3/4 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 20A/250V Locking Receptacle, 2 Communications Receptacles, City of Chicago Approved
FPT4-8C-C
Poke-Through Base Unit, Length 19 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 8 Communications Receptacles, City of Chicago Approved
FPT4-1TL32-2C
Poke Through Base Unit, Length 19-3/4 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 30A/250V Locking Receptacle, 2 Communications Receptacles
FPT4-4P-4C-C
Poke-Through Base Unit, 4 Inch Drill Size, 19 Inch Length, Hub Size 1/2 Inch and 1 Inch, Galvanized Steel, with 4 20A Power Receptacles and 4 Cat-5e Data Jacks with Device Plates, City of Chicago Approved
FPT4-2P-6C
Poke-Through Base Unit, Length 19 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 2 20A Power Receptacles, 6 Communications Receptacles
FPT4-4P-4C
Poke-Through Base Unit, 4 Inch Drill Size, 19 Inch Length, Hub Size 1/2 Inch and 1 Inch, Galvanized Steel, with 4 20A Power Receptacles and 4 Cat-5e Data Jacks with Device Plates
FPT4-8C
Poke-Through Base Unit, Length 19 Inches, Diameter 7-1/2 Inches, Hub Size 1/2 Inch, Galvanized Steel, 8 Communications ReceptaclesFrequently Asked Questions
What are the power receptacle specifications for this poke-through?
The device includes a 20 A/125 V locking receptacle with pre-wired three 12 AWG wires and pigtail ends in the junction box.
What is the core drill size required for installation?
The core drill size for this poke-through is 4 inches.
What communication capabilities does this poke-through have?
The poke-through includes two communications receptacles with keystone device plates and two category 5e data jacks.
What are the installation spacing requirements?
Poke-throughs must be installed with a minimum of 2 feet on center and not more than one poke-through per 65 square feet of floor area in each span.
What materials are used in the construction of this poke-through?
The base is made of die-cast zinc, galvanized steel, and intumescent fire-stop material. Covers are available in solid brass or aluminum with various finishes.
How to Install the FPT4-1TL21-2C Poke-Through
This guide provides step-by-step instructions for installing and wiring the FPT4-1TL21-2C Poke-Through unit, ensuring compliance with safety standards.
Estimated time: 1h
Tools needed:
Screwdriver, Core drill, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Conduit fittings
- Determine Installation Location
Select a location for the Poke-Through that is at least 4-1/4 inches from any wall or pillar. Ensure the spacing is a minimum of 2 feet on center and not more than one device per 65 sq. ft. of floor area.
- Drill the Hole
Core drill a 4-inch diameter hole in the floor using the provided template. Ensure the hole is clean and free of debris before proceeding.
- Insert Base Unit
Insert the base unit into the drilled hole. Push down until the screws in the temporary cover contact the concrete floor. Ensure the orientation of the receptacles and communication outlets is correct before insertion.
- Install Cover
Remove the temporary cover and install the FPT4 series cover according to the instructions provided with the cover.
- Make Electrical Connections
Remove the cover from the junction box and make the necessary wiring connections as per the wiring diagram. Ensure the ground screw is connected to the system ground.
- Complete Communication Connections
Install communication cables and jacks after the cover is secured to the floor. Ensure all connections are properly seated.
- Verify Installation
Check all connections and ensure the unit is securely mounted. Test the electrical and communication connections with a multimeter to confirm functionality.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.