ABB Installation Products 3701A3-H 200 Amp, 35kV Loadbreak Bushing Insert, Includes internal torquing feature using 200AT…
UPC: 783786470365
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp continuous and loadbreak rated for 35kV class applications
- Meets ANSI/IEEE Standard 386 with 150kV BIL and 50kV AC withstand
- Internal torquing feature requires 200AT Assembly Tool for precise installation
- Includes black vent ring for pressure and heat management
- Compatible with ANSI bushing wells for sub-surface transformers, switchgear, and reclosers
Specifications
Application | 35 kV, 200 Amps |
Color | Black |
Connection Type | Loadbreak Bushing Insert |
Current Rating | 200 A |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Bushing Insert |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.5000 L |
Package Weight (Metric) | 1.5880 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
K1501-A1-H
200 Amp, 15/25kV, DeadBreak Elbow, Bushing Insert, Bails are required, but not included, order separately.
655-3 INS
600 Amp Voltage Detection Cap,Test Point Cap. 3.08 inch x 3.358 inch Diameter. Pull Eye. EPDM Peroxide Insulation.Frequently Asked Questions
What items are included in the 3701A3 kit?
Each kit contains the 3701A3 bushing insert, a protective shipping cap (2701-41), lubricant (82-08), and installation instructions (IS-0358).
What is the 3701A3 bushing insert?
The 3701A3 is a 35kV class, 200 Amp load break bushing insert. It serves as an apparatus bushing interface for elbow connections.
What is the primary application of the 3701A3?
It is used as the bushing interface for connecting shielded cable to sub-surface transformers, generators, pad mounted transformers, regulators, switchgear, and reclosers.
What type of bushing well does the 3701A3 fit?
The 3701A3 bushing insert fits a standard ANSI bushing well interface. It is easily installed in an Elastimold® universal bushing well.
What standards does the 3701A3 meet?
The 3701A3 bushing insert meets ANSI/IEEE Standard 386, Latest Revision.
What is the maximum operating voltage for the 3701A3?
The maximum phase-to-ground operating voltage is 21.1kV, and the maximum phase-to-phase voltage is 36.6kV.
What is the impulse withstand (BIL) rating?
The impulse withstand (BIL) rating for the 3701A3 is 150kV (1.2 x 50 microsecond wave).
Is the 3701A3 rated for single or three-phase switching?
Yes, the 3701A3 is rated for both 1 Ø and 3 Ø switching applications.
What type of insulation does the 3701A3 use?
The 3701A3 features peroxide-cured insulation and jacket.
Does the 3701A3 have a ground wire connection?
Yes, the 3701A3 bushing insert includes a provision for ground wire connection.
How to Install the 3701A3-H Loadbreak Bushing Insert
Instructions for installing the 3701A3-H Loadbreak Bushing Insert into apparatus for 35KV class loadbreak connectors.
Estimated time: 30m
Tools needed:
Screwdriver, Wire strippers, Pliers
Supplies needed:
Lubricant (supplied), Copper wire (No. 14 AWG or equivalent), Suitable connector for system ground, Insulated cap or grounding elbow connector (if not immediately mating)
- Prepare the apparatus and bushing insert
Ensure the apparatus bushing well is dry and free from contaminants. Remove the protective shipping cap from the bushing insert. Lubricate the bushing well interface area of the bushing insert with the supplied lubricant. Do not substitute lubricants.
- Install the bushing insert
Place the lubricated bushing insert into the apparatus bushing well. Hand tighten the bushing insert clockwise until it bottoms.
- Connect the electrostatic grounding wire
Thread a length of No. 14 AWG (2.5mm²) copper wire through one of the grounding tabs on the bushing insert. Create a small loop and twist it tight, being careful not to damage the tab. Connect the free end of this wire to the system ground using a suitable connector. Ensure the grounding wire does not contact the bushing interface or interfere with nearby components.
- Complete the installation and mating
Thoroughly clean and lubricate the bushing insert interface. Install mating products (e.g., elbow connector) according to their specific instructions. If not immediately mating, replace the shipping cover. Do not energize or submerge the apparatus with the shipping cover in place, as it is not insulated or watertight.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.