ABB Installation Products 756LR-N0360-S 35kV, 600 Amps, Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…
UPC: 075114388054
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV voltage class with 21.1kV max phase-to-ground and 36.6kV max phase-to-phase operating voltage
- 600 Amp continuous current rating with 25kA symmetrical momentary rating (10 cycles)
- Fully shielded, dead-front submersible molded rubber housing with 100% peroxide-cured EPDM construction
- Accommodates conductor sizes from 650 kcmil (compressed/stranded) to 750/800 kcmil (compacted/solid)
- Cable insulation diameter range: 1.515" to 1.780". Cold-shrinkable jacket seal included for environmental protection
Specifications
Amperage Rating | 600 A |
Application | 35 kv, 600 Amp |
Color | Black |
Conductor Range | 650 kcmil , 750 to 800 kcmil |
Connection | Compression |
Connection Type | Deadbreak Elbow with Test Point |
Current Rating | 600 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Poles | 1 |
Series | 756LR |
Size | Cable Insulation Diameter 1.515 inch to 1.780 inch, Conductor Size Compressed/Stranded 650 kcmil or Compacted/Solid 750/800 kcmil |
Size | Cable Insulation Diameter 1.515 inch to 1.780 inch |
Special Features | 35kV, 600 Amp Deadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. S - Cold-Shrinkable Jacket Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Width | 12.28 in |
Width | 311.912 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

756LRTP-P0360
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
K655VSL2-L0330-SG3
15/25kV, 600 Amps, 2-Way Vault-Stretcher. Cable Insulation Diameter range 1.37-1.63 inch (34.8-41.4mm). Connector Sizing 330 - 500 kcmil Stranded / Compressed, 600 kcmil Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Compression Lugs, (2) Cable Adapters (2) Insulated Plugs with Caps (1) Stud. Lubricant, Installation Instruction Sheet. Cold Shrinkable Seal with Copper Braid and Constant Force Spring also Included. Vault Stretcher Housing 21.75 inches x 8,69 inches.
755LRTP-H0240-SG3
600 Amp, 35kV, Stick-Op Connector Kit without Test Point and Sealing Kit. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size 240 - AWG Compressed-Stranded 1/0 or Compacted-Solid 2/0. Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring. Does not include Insulated Plug.
755ETP-M0330-SG3
600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil. Includes Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
375LR-K-2240
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K656LR-J2330
Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter .980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 500 or Solid 600 or mm2 250/300.
168FLR1C5230
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Crimp Connector, Conductor size #1 Stranded/Compressed or 1/0 Solid/Compact.Frequently Asked Questions
What is the primary application of the 756LR?
The 756LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.
What is the continuous current rating of the 756LR?
The continuous current rating for the 756LR is 600 Amp.
How should the 756LR be connected or disconnected?
It should be connected or disconnected using standard hand tools and equipment in a de-energized state.
What materials are used for the elbow housing?
The housing is a fully shielded, fully submersible molded rubber, constructed with 100% peroxide-cured EPDM materials.
Which industry standard does the 756LR meet?
The 756LR meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand (BIL) rating?
The impulse withstand (BIL) rating is 150kV.
What is the maximum phase-to-phase voltage rating?
The maximum phase-to-phase voltage rating is 36.6kV.
What is the maximum phase-to-ground operating voltage?
The maximum phase-to-ground operating voltage is 21.1kV for the 35kV voltage class.
What cable insulation diameters does the 756LR support?
It supports insulation diameters from .760 inches to 2.120 inches.
What conductor sizes are compatible with the 756LR?
It is compatible with #2 AWG to 1250 kcmil for aluminum and copper conductors.
How to Install the 756LR Deadbreak Elbow Connector
This guide provides step-by-step instructions for the safe and proper installation of the 756LR Deadbreak Elbow Connector, designed for fully shielded, submersible cable connections on 35kV class systems.
Estimated time: 2h
Tools needed:
Cable cutting tool, Cable cleaning supplies, Cable preparation tools, Crimping tool, Wire brush (for aluminum conductor), Torque wrench, Hotstick, Suitable voltage sensing device for capacitive test points, Wire strippers
Supplies needed:
756LR Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, etc.), Cable (appropriate type and rating), Grounding wire (No. 14 AWG Copper or equivalent), Suitable grounding connector, Waterproofing material, HV insulated cap(s) or connector(s), Mating product (apparatus bushing, connector plug, etc.)
- Safety First: De-energize and Inspect
Ensure all apparatus is de-energized before beginning installation. Inspect all kit contents for completeness and damage. Verify that all components are rated and compatible with the cable and mating products.
- Prepare the Cable for Connection
Position the cable with enough slack for final assembly. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer jacket for a distance of 24” (610mm). Remove the outer jacket and prepare the cable insulation and semi-con shield to the dimensions specified in the product diagrams (e.g., 10-3/8”, 11-3/8”, 13-5/8” from the end), following specific instructions for your cable type (Unishield, Lead Sheath, Jacketed, Non-Jacketed).
- Install and Secure the Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare Conductor and Crimp Lug
Carefully remove the protruding cable insulation, cutting it even with the end of the cable adapter, ensuring not to nick the adapter or conductor. The exposed conductor length must be between 4-3/8” to 4-3/4” (111mm-121mm). Insert the conductor fully into the compression lug (wire brush aluminum conductors immediately before insertion). Measure the 'Check Dimension' (must be less than 7” (178mm)) before crimping. Crimp the lug according to its supplied instructions. Wipe off any excess inhibitor and verify the post-crimp distance from the lug end to the cable adapter is 6-7/8” to 7-5/8” (175mm-194mm).
- Install the Elbow Connector
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Confirm the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect Elbow to Mating Apparatus
Before connecting, ensure the apparatus is de-energized. Remove any protective caps from the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud (supplied with the elbow) into it. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud. If connecting a second mating part (for splicing/tapping), clean and lubricate it, then insert it into the opposite end of the elbow, engage threads, hand tighten, and torque as per its instructions.
- Ground the Cable Shield and Waterproof
Insert a No. 14 AWG Copper (or equivalent) wire through the grounding eye and twist to form a small loop. Connect this wire to ground using a suitable connector. Ensure the cable shield is properly grounded, either via a grounding device or an alternate method. It is recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test (Post-Installation)
If an insulating plug is used, clean and lubricate its voltage detection cap and snap it onto the elbow. To test for voltage, remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable capacitive sensing device (not conventional voltage equipment) to determine if the cable is energized, following the device manufacturer's instructions. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the cap, then replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.