ABB - Installation Products 756LR-H0240 - 600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products 756LR-H0240 600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786422333


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-H0240 is a 600 Amp, 35kV DeadBreak Elbow connector engineered for medium-voltage cable systems. This fully shielded, dead-front submersible elbow provides a reliable, fully rated connection for 35kV class equipment, meeting ANSI/IEEE Standard 386 requirements. The connector accommodates cable insulation diameters from 0.850 inch to 1.050 inch, making it compatible with a range of cable types. The included aluminum compression lug supports conductor sizes from 1/0 AWG to 2/0 AWG (or equivalent 53.49 mm² solid/compressed stranded), ensuring a secure, low-resistance connection that minimizes heat generation and ensures long-term reliability. The 756LR-H0240 is designed for utility substations, industrial power distribution, renewable energy interconnects, and commercial facilities requiring dependable medium-voltage connections. The deadbreak design allows for safe hot-stick operation, reducing downtime during maintenance or testing. The fully molded rubber housing and 100% peroxide-cured EPDM construction provide durability and environmental resistance. Optional accessories enable visible external separation, bypass, isolation, dead-ending, grounding, and testing, as well as adding taps, surge arrestors, and fault current indicators. The unit comes fully assembled with an insulated plug, cap, stud, and cable adapter for immediate installation.
  • 600 Amp, 35kV DeadBreak Elbow with integrated test point for safe voltage verification
  • Accommodates cable insulation diameters from 0.850 inch to 1.050 inch
  • Aluminum compression lug supports 1/0 AWG to 2/0 AWG (53.49 mm²) conductors
  • Fully shielded, dead-front submersible molded rubber housing with 100% peroxide-cured EPDM construction
  • Designed for utility substations, industrial power distribution, and renewable energy interconnects

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Compression
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
9.25 IN x 14 IN x 11.25 IN
Package Dimensions (L x W x H)
23.495 cm x 35.56 cm x 28.575 cm
Package Weight (Imperial)
8.6000 L
Package Weight (Metric)
3.9010 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

756LR-L0240

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.

756LR-L0290

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

756LR-L0280

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-L2270-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

756LR-M0280

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

756LR-L0320

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. With Cold-Shrinkable Jacket Seal. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Copper Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Solid/Compact or 95 mm2. Thin Walled. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-G-2260-S

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. With Cold-Shrinkable Jacket Seal. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Copper Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Solid/Compact or 95 mm2. Thin Walled. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

Frequently Asked Questions

What materials are used in the connector's construction?

The connector features 100% peroxide-cured construction, including insulation and conductive EPDM materials.

Is the 756LR connector designed for submersible applications?

Yes, the 756LR features a fully shielded and fully submersible molded rubber housing.

What is the impulse withstand rating (BIL)?

The impulse withstand (BIL) rating is 150kV, based on a 1.2 x 50 microsecond wave.

What cable insulation diameters does the connector support?

The connector supports cable insulation diameters from 0.760 inches to 2.120 inches.

What cable conductor sizes are compatible with the 756LR?

The 756LR is compatible with aluminum and copper conductors ranging from #2 AWG to 1250 kcmil.

What is the continuous current rating of the connector?

The 756LR elbow connector has a continuous current rating of 600 Amps.

What is the maximum operating voltage for the 756LR?

The maximum phase-to-ground operating voltage is 21.1kV, and the maximum phase-to-phase is 36.6kV for the 35kV voltage class.

What is the momentary current rating of the connector?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What industry standards does the 756LR meet?

The 756LR meets ANSI/IEEE Standard 386, Latest Revision.

What items are included in a 756LR kit?

Each kit contains an elbow connector housing, copper compression lug, stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

How to Install 756/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR and 776LR Deadbreak Elbow Connectors, designed for fully shielded, submersible high-voltage cable connections on 35kV class systems.

Estimated time: 2h

Tools needed:

Wire strippers, Wire brush (for aluminum conductors), Crimping tool, Hotstick, Suitable voltage sensing device (for capacitive test points)

Supplies needed:

756LR or 776LR Deadbreak Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Crimp connector, Lubricant, Stud Prepack), No. 14 AWG Copper wire (or equivalent) for grounding, Suitable grounding connector, HV insulated caps (if replacing shipping covers), Tape marker

  1. De-energize Apparatus and Inspect Parts

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, proper rating, and compatibility with mating parts. Remove any protective shipping covers and replace them with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Check package contents for completeness and ensure all components fit properly with the cable and/or mating products.

  2. Position and Cut Cable

    Position the cable in its final assembled location, ensuring enough slack to provide adequate clearance for removing the elbows. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Jacket

    Clean the outer jacket of the cable for a distance of 24” (610mm).

  4. Prepare Cable for Connection

    Refer to the specific installation instructions supplied with 20MA or 21MA grounding devices, 600ECS Jacket Cable Seals, UNISHIELD*, or LEAD SHEATH cables for their respective cable preparation. For jacketed and non-jacketed cables, remove the outer jacket (where applicable) and prepare the cable according to the provided diagrams, ensuring correct dimensions for cable insulation, semi-con shield, and tape markers.

  5. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-3/8” to 4-3/4” (111mm-121mm). If the length is outside this range, redo the assembly.

  7. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the “Check Dimension” before crimping; this dimension should be less than 7” (178mm). Crimp the compression lug following the crimping instructions supplied with the lug. After crimping, wipe all excess inhibitor from the compression lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-7/8” to 7-5/8” (175mm-194mm). If the dimension is outside this range, redo the assembly.

  8. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Ensure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  9. Prepare Mating Products

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  10. Connect Elbow to Mating Part

    Push the elbow onto the mating part, aligning the hole in the compression lug with the stud on the mating part.

  11. Connect Opposite Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that mating part.

  12. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage; follow the voltage test directions below.

  13. Ground Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with the grounding device. If no grounding device is used, the shield must be grounded through an alternate method. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  14. Perform Voltage Test (if applicable)

    CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per the instructions provided with the plug connectors. If the ELASTIMOLD® connector is equipped with an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false “no voltage” indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.