ABB Installation Products 756LR-L0290 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…
UPC: 783786462995
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV rated deadbreak elbow for medium-voltage cable terminations
- Accommodates cable insulation diameters from 1.180" to 1.465"
- Compatible with AWG/kcmil compressed stranded (300), compacted solid (350), or mm² compact (150) conductors
- Includes insulated plug, cap, stud, lug, and cable adapter for complete installation
- Test point enables safe voltage verification without de-energizing the system
Specifications
Amperage Rating | 600 A |
Application | 35 kv, 600 Amp |
Color | Black |
Conductor Range | 300 kcmil , 350 kcmil |
Connection | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | 35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Width | 12.28 in |
Width | 311.912 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 9.0000 L |
Package Weight (Metric) | 4.0820 kg |

755LR-M0290
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.
756LR-L0280
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
756LR-L2270-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
756LR-M0280
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
756LR-L0320
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
K465LR-G-2260-S
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. With Cold-Shrinkable Jacket Seal. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Copper Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Solid/Compact or 95 mm2. Thin Walled. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
756LR-L2330
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
K465LR-J-2300-S
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. With Cold-Shrinkable Jacket Seal. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Copper Compression Lug, Conductor Size 350 Stranded/Compressed or 400 Solid/Compact or 185 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.Frequently Asked Questions
Can the 756LR be connected while energized?
No, the 756LR must be connected or disconnected using standard hand tools and equipment only in a de-energized state.
What is the primary application of the 756LR?
The 756LR is designed for fully shielded, dead-front submersible cable connections to high-voltage apparatus.
What is the maximum voltage rating for the 756LR?
The 756LR can be used through 35kV, with a maximum phase-to-ground operating voltage of 21.1kV.
What conductor sizes are compatible with the 756LR?
It is compatible with #2 AWG to 1250 kcmil for aluminum and copper conductors.
What cable insulation diameters does the 756LR support?
The 756LR supports insulation diameters from 0.760 inches to 2.120 inches.
What standard does the 756LR meet?
The 756LR meets ANSI/IEEE Standard 386, Latest Revision.
What is the continuous current rating of the 756LR?
The continuous current rating for the 756LR is 600 Amp.
What is the impulse withstand (BIL) rating?
The impulse withstand (BIL) rating is 150kV.
What is the AC one-minute withstand voltage?
The AC one-minute withstand voltage is 50kV.
Is the 756LR submersible?
Yes, the 756LR features a fully shielded, fully submersible molded rubber housing.
How to Install 756/776LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for installing 756/776LR Deadbreak Elbow Connectors. These connectors provide fully shielded, submersible deadfront cable connections for 600-ampere or 900-ampere, 35kV class systems.
Estimated time: 2h
Tools needed:
Crimping tool, Wire brush, Hotstick, Suitable voltage sensing device, Wire strippers, Cutting tool, Multimeter
Supplies needed:
756/776LR Deadbreak Elbow Connector kit, Cable (appropriate type for 35kV class systems), Grounding device or suitable grounding connector, No. 14 AWG Copper wire (or equivalent ampacity), Waterproofing material (for cable jacket)
- Ensure Safety and Prepare Components
Before beginning, ensure all apparatus are de-energized. Verify the contents of the connector package are complete and undamaged. Inspect all components for proper fit with the cable and mating products. This installation must only be performed by competent personnel trained in high voltage electrical safety practices and in accordance with all local and national work rules.
- Position and Cut Cable
Position the cable in its final assembled location, ensuring enough slack to allow for elbow removal. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer jacket of the cable for a distance of 24 inches (610mm).
- Prepare Cable End
Prepare the cable according to its type (Unishield, Lead Sheath, Jacketed, or Non-Jacketed) as detailed in the specific instructions for your cable type or the provided diagrams. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Expose Conductor and Install Compression Lug
Remove the protruding cable insulation, cutting it even with the end of the cable adapter. Ensure the exposed conductor length is between 4-3/8 inches (111mm) and 4-3/4 inches (121mm). For aluminum conductors, wire brush the conductor immediately before insertion. Fully insert the conductor into the compression lug. Measure the 'Check Dimension' (must be less than 7 inches / 178mm) before crimping. Crimp the compression lug according to its supplied instructions. After crimping, wipe off all excess inhibitor. Verify the distance from the end of the compression lug to the cable adapter is between 6-7/8 inches (175mm) and 7-5/8 inches (194mm).
- Install Elbow onto Cable Adapter
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Confirm the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect Elbow to Mating Product
Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the supplied threaded stud into it. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, aligning the compression lug's hole with the mating part's stud. For the opposite end, clean and lubricate the mating part, insert it into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions. Do not connect or disconnect while energized, and do not energize while disconnected.
- Install Insulating Plug and Ground Cable
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing down until it snaps into place. Insert one end of a No. 14 AWG Copper wire (or equivalent) through the grounding eye, twist to form a small loop, and connect it to ground using a suitable connector. Ensure the cable shield is grounded either via a grounding device or an alternate method. Waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test
If the connector has an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, specifically designed for capacitive test points, to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.