Authorized ABB Distributor (Installation Products)
ABB - Installation Products 755ETP-M0300-DRG - 600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

ABB Installation Products 755ETP-M0300-DRG 600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap…

UPC: 783786461097


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 755ETP-M0300-DRG Deadbreak Test & Ground Connector Kit is a high-performance solution for medium-voltage electrical systems requiring safe, reliable testing and grounding at 35kV. Designed for 600 Amp applications, this kit includes a deadbreak elbow housing, insulated cap, reducing tap plug, cable adapter, and 0370-style aluminum compression lug to ensure secure, watertight connections. Engineered for compatibility with compressed stranded conductors from 350 kcmil, compacted solid conductors up to 400 kcmil, and mm² compact conductors of 185, the kit supports cable insulation diameters ranging from 1.370 inches to 1.630 inches. The 0370 aluminum compression lug provides robust conductivity and corrosion resistance, while the included lubricant tube ensures smooth installation. Installation requires the ABB 600ATM assembly tool and a 50-60 foot-pound torque wrench (sold separately) to achieve proper torque specifications. This kit is ideal for medium-voltage infrastructure, including power distribution, substations, and industrial facilities where deadbreak connections are critical for maintenance and safety. The deadbreak design allows for hot-stick operation, enabling safe testing and grounding without de-energizing the system. The kit's components are precision-engineered to meet the demands of high-voltage environments, ensuring long-term reliability and performance.
  • 600 Amp, 35kV deadbreak test and ground connector kit
  • Includes insulated cap, reducing tap plug, elbow housing, cable adapter, and 0370-style aluminum compression lug
  • Supports compressed stranded conductors from 350 kcmil to compacted solid conductors up to 400 kcmil
  • Accommodates cable insulation diameters from 1.370 inches to 1.630 inches

Specifications

Amperage Rating
600 A
Application
600 Amps, 35kV
Color
Black
Conductor Range
350 STR/COMPR kcmil , 400 SOL/COMPT kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
600 A
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
755ETP
Size
Cable Insulation Diameter 1.370 inch to 1.630 inch
Special Features
Includes Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV, 900 Amp, Extended Elbow, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.

K676ELR-J5300-S

25 kV, 900 Amp, Extended Elbow, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.
900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.

675ETPSP-L2330-DRG

900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

656ETP-N0400-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torrque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

755ETP-M0260-DRG

600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torrque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.

656ETP-N0410

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.
900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

675ETPSP-J2300

900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.

K655ETP-M0330-DRG

25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

655ETP-L0330

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

Frequently Asked Questions

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What is the corona extinction voltage rating?

The corona extinction rating is 26kV AC at 3pC sensitivity.

What is the DC 15-minute withstand voltage rating?

The DC 15-minute withstand voltage rating is 103kV.

What is the AC one-minute withstand voltage rating?

The AC one-minute withstand voltage rating is 50kV.

What conductor materials are supported by the connector?

The connector supports Universal Aluminum, Copper, and Bi-metal conductor types.

What are the main applications of this connector kit?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows for an internal visible break.

What items are included in the 755ETP-W0X-DRG kit?

The kit includes an Elbow Housing, Elbow Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Silicone Lubricant, and various Instruction Sheets and a Crimp Chart.

What is the impulse withstand rating for the connector?

The impulse withstand rating (BIL) is 150kV (1.2 x 50 microsecond wave).

What industry standards does this connector meet?

The connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the connector?

The connector has a continuous current rating of 600 Amps.

How to Install the 750/775 ETP Elbow Tap Plug

This guide provides step-by-step instructions for the safe installation and assembly of the 750/775 ETP Elbow Tap Plug, including cable preparation, connector assembly, and grounding procedures for high-voltage applications.

Estimated time: 1h 30m

Tools needed:

Wire preparation tools (strippers, crimpers), Drive adapter, Torque wrench (50-60 ft-lbs), General hand tools

Supplies needed:

750/775 ETP Tap Plug, Lubricant (DO NOT SUBSTITUTE), Double ended stud (if applicable), Spade contact, Elbow connector, Mating connector, #14AWG copper wire (or equivalent), Appropriate connector for grounding, Waterproofing material (if cable is jacketed), Jumper wire (for metallic tape shielded cable, if applicable), DR(G), ESA, GLR, LR, or Insulated Cap (appropriate voltage class)

  1. Ensure Safety and Inspect Components

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Verify that the available fault current is limited to 10,000 amperes. Inspect all package contents and components for completeness, damage, proper rating, and compatibility with mating parts. Confirm all required tools are at hand and maintain cleanliness throughout the procedure. This product must only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Tap Plug and Interfaces

    Remove any protective shipping covers from the tap plug and elbow connector. If applicable, finger tighten the double-ended stud into the tap plug. Clean and thoroughly lubricate the entire mating connector interface, elbow connector interfaces, and the tap plug using the supplied lubricant or an ELASTIMOLD approved lubricant.

  3. Prepare Cable and Install Elbow Connector

    Prepare the cable using a spade contact. Before crimping, align the spade contact on the cable so it lies flat on the apparatus bushing contact. Install the elbow connector onto the cable as described in the (K)650LR or 750LR installation instructions.

  4. Assemble Elbow and Tap Plug to Mating Connector

    Assemble the elbow connector onto the mating connector. Then, assemble the tap plug into the elbow connector. Insert the drive adapter into the tap plug and turn it clockwise while simultaneously pushing the elbow and tap plug towards the mating connector. Continue rotating the drive adapter clockwise with an appropriate tool to a torque of 50-60 ft-lbs. Remove the drive adapter from the tap plug.

  5. Install Grounding Eye Wire

    Insert one end of a #14AWG copper wire (or equivalent) through the grounding eye of the elbow. Leave sufficient length to allow for potential movement of the elbow. Form a small loop and twist it tightly, being careful not to damage the grounding eye.

  6. Ground the Cable Shield and Eye Wire

    For concentric wire shielded cable, twist the shield wires together and connect them, along with the grounding eye wire, to a common ground point using an appropriate connector. For metallic tape shielded cable, connect the metallic shield to ground using a jumper of equivalent ampacity to the shield, and connect the elbow connector grounding eye wire to ground. Ensure sufficient length is left for movement. For three-phase installations, tie all grounds from all three phases to a common ground point. If the cable is jacketed, install appropriate waterproofing at the jacket terminus to prevent moisture ingress.

  7. Install Final Component (Cap or Connector)

    Clean and lubricate the entire tap plug interface. Install either a DR(G), ESA, GLR, LR of the appropriate voltage class, or an insulated cap onto the tap plug interface. Follow the specific installation instructions provided with the chosen product.

  8. Verify Proper Seating

    Confirm that the assembly of the insulated cap or elbow is complete by verifying that no portion of the black band is visible when viewed from the side.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.