
ABB Installation Products 675ETPSP-L2330-DRG 900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field…
UPC: 783786442539
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 900 Amp, 15kV Loadbreak Elbow Tap Plug
- Factory-assembled with non-field-removable stud
- Copper compression lug for reliable connections
- Accommodates cable insulation diameters from 0.980" to 1.180"
- Compatible with 500-600 kcmil stranded/solid conductors and 250-300 mm² compact conductors
- Includes insulated cap for safety and contamination protection
- Compliant with ANSI/IEEE C119.4 standards
Specifications
Amperage Rating | 900 A |
Application | 900 Amps, 15kV |
Color | Blue |
Color | Black |
Conductor Range | 500 STR/COMPR kcmil , 600 SOL/COMPT kcmil |
Connection | Compression |
Connection Type | Loadbreak Connector |
Connection Type | Compression Lug |
Current Rating | 900 A |
Insulation | EPDM Rubber |
Material | Copper |
Material | Copper, EPDM |
Material | Copper, Poly |
Material | Housing - EPDM-Rubber |
Series | 675ETPSP Series |
Series | 675ETPSP |
Size | Cable Insulation Diameter 0.980 inch to 1.180 inch |
Size | 0.980-1.180 inch (insulation diameter) |
Size | Cable Insulation Diameter 1.180 inch to 1.465 inch |
Special Features | Includes Insulated Cap and Sealing Kit |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Window-Op Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655ETP-M0330-DRG
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.
656ETP-N0400-DRG
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
755ETP-M0260-DRG
600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torrque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
656ETP-N0410
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 1000.
675ETPSP-J2300
900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
655ETP-L0330
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.Frequently Asked Questions
What is the primary function of the 675ETP elbow tap plug?
The 675ETP elbow tap plug allows a 200 Amp tap from a mating 900 Amp connector.
How can I order the 675ETP with a loose stud?
To order the 675ETP with a loose stud, add the suffix "S" to the part number.
How do I order the 675ETP with a factory-assembled stud?
To order the 675ETP with a factory-assembled stud, add "SP" to the part number.
What items are included in each 675ETP kit?
Each kit contains one 675ETP Bushing Insert, one 1601-APC-1 Protective shipping cap, two 82-08 Lubricants, and one IS-0766 Installation Instruction.
How can I visually confirm proper installation?
A Seating Indicator provides a visual check to confirm that mating components are properly installed.
Can the loadbreak interface be operated while energized?
Yes, the loadbreak interface is specifically designed for energized operation.
What is the impulse withstand rating for the 675ETP?
The 675ETP has a 95kV BIL impulse withstand rating.
What is the continuous current rating for the deadbreak interface?
The deadbreak interface has a continuous current rating of 900 Amp.
What is the continuous and loadbreak current rating?
The loadbreak interface is rated for 200 Amp continuous and loadbreak current.
What are the maximum operating voltages for the 675ETP?
The maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the safe and proper installation of the LINK-C 600 amp Deadbreak Cam Link Operable Connector System, including mounting, lubrication, and grounding procedures for high voltage electrical equipment.
Estimated time: 2h
Tools needed:
Torque Wrench, 1" Hex Tool, Hot Stick, Wire Strippers, Welding Equipment (if using welded studs), Suitable Connector Crimping Tool
Supplies needed:
ELASTIMOLD Lubricant, Hex Nuts (3/8-16), Lockwashers, Studs (3/8-16 x 2" long, if using welded studs), #14 AWG or #12 AWG Solid Copper Wire, Appropriate Grounding Connectors, HV Insulated Caps (if replacing shipping covers), Spacers (optional, for stand-off plug support)
- Prepare for Installation and Safety Checks
DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products. Failure to follow these instructions will result in serious or fatal injury. Inspect all components for damage, proper rating, and compatibility with mating parts. Ensure all required tools and supplies are at hand and maintain cleanliness throughout the procedure. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing the circuit.
- Install the 600 Amp Elbow
Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure it will align correctly with the stand-off plug or apparatus bushing.
- Mount the Stand-Off Plug (If Applicable)
Weld three 3/8-16 x 2” long studs to the faceplate according to the specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the apparatus bushing; spacers may be used if nuts are not required for support. Place the stand-off plug over the three studs, resting it on the nuts or spacers. Install a lockwasher and hex nut on each of the three studs and tighten to 12 ft-lbs torque. Verify that the top surfaces of the apparatus bushing and stand-off plug are in-line; readjust nuts as necessary.
- Install Bushing Extender and Elbow
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact and engage its internal hex broach. Insert the retainer contact into the bushing extender and thread it into the apparatus bushing using a 1” hex tool on the 600ATM, torque to 50-60 ft-lbs. Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600AMT into the retainer contact and engage its internal hex broach. Insert the retainer contact into the 600 amp elbow through the compression lug hole and thread it into the epoxy standoff plug using a 1” hex tool on the 600AMT, torque to 50-60 ft-lbs.
- Install the Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware. Torque by alternating sides until the clamp tabs are flush with each other and tight on both sides.
- Position and Secure the Elbow
Position the elbow within the alignment bracket so that the elbow cuff is evenly lined up with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware. Torque by alternating sides until the clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Insert the LINK-C Connector
Clean and thoroughly lubricate both 600 ampere interfaces of the LINK-C connector with ELASTIMOLD lubricant. Align the LINK-C connector to be perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the LINK-C connector into the bushing extender and elbow, ensuring both lever arms are inside the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick eye to move the lever arms downward, engaging the roller pin and moving the LINK-C inward. Continue until the lever arms are perpendicular to the alignment bracket leg.
- Ground the System and Install Mating Products
Ground the elbow: Feed a #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twist it tight, and connect it to ground. Clean and lubricate the 200 amp interface on the LINK-C connector. Ground and then install the desired mating product onto the 200 amp interface according to its specific installation instructions. Ground the cable: If using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector. If using 20MA or 21MA grounding devices, connect their ground lead to ground using a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.

