Contact for Pricing
Overview
- 69 kV Transmission Cable Joint
- Shieldbreak Housing Type, Housing Style 1
- Bore Diameter at Jacket/Insulation Transition: 1.750 inches
- Conductor Diameter Range: 1.036-1.100 inches (26.31-27.94mm)
- Shield Type D (Copper Tape and Neutral Wire)
Specifications
Application | For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications |
Color | Black |
Conductor Range | 1.036 to 1.100 in |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Special Features | Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities |
Standard | ANSI C119.4, Shield Test IEEE 592 |
Temperature Rating, Maximum | 194 F |
Temperature Rating, Maximum | 90 C |
Temperature Rating, Minimum | 194 F |
Temperature Rating, Minimum | 90 C |
Type | Transmission Cable Joint - Shieldbreak |
Voltage Rating | 69 kV |
Package Dimensions (L x W x H) | 51 IN x 10 IN x 10 IN |
Package Dimensions (L x W x H) | 129.54 cm x 25.4 cm x 25.4 cm |
Package Weight (Imperial) | 25.2500 L |
Package Weight (Metric) | 11.4530 kg |

69TCJS1P240PNDNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
25PCJ2M2290
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 350.
35PCJ1L2270SG3
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
69TCJS44B56PNOLNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 56P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size N - not required, Heatsink Bore - O - not included. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
35PCJ1N1320
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
25PCJ1K2270
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
69TCJS4-4-4Q
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, - 4Q
25PCJ2J1270-H1230
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.Frequently Asked Questions
What safety precaution is mentioned for installation?
For installation, customers should refer to local code for required Personal Protective Equipment (PPE).
What are TCJ transmission cable joints used for?
TCJ transmission cable joints are designed for 46 kV through 138 kV class systems on solid dielectric cables. They provide permanent, fully shielded, fully submersible joints for direct-burial or vault applications.
What cable insulation diameters are supported?
For Style 1 (through 69 kV), insulation diameters are 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), they are 2.25 inches to 3.62 inches.
Can TCJ joints be used for direct-burial?
Yes, when assembled, TCJ transmission cable joints provide permanent, fully shielded, fully submersible cable joints suitable for direct-burial or vault applications.
What is the voltage class for 69TCJS1Q?
The 69TCJS1Q joint is designed for a 69 kV nominal voltage class with a maximum system voltage of 72.5 kV.
What is the insulation diameter range for 69TCJS1Q?
For the 69TCJS1Q, the insulation diameter range is from 1.995 inches to 2.300 inches.
What are the dimensions of the 69TCJS1Q joint housing?
The joint housing for the 69TCJS1Q has a diameter of 4.75 inches and a length of 22.48 inches.
What materials are used in the pre-molded housing?
The void-free joint housing consists of peroxide-cured EPDM insulation bonded under pressure to peroxide-cured molded semi-conductive elements.
What is the maximum system voltage for a 69 kV joint?
For a 69 kV nominal system voltage, the maximum system voltage is 72.5 kV.
What is the BIL rating for a 69 kV joint?
The Basic Impulse Level (BIL) rating for a 69 kV joint is 350 kV (1.2 x 50μs; 10 positive, 10 negative impulses).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.