ABB Installation Products 25PCJ1K2270 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786529131
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 25kV class power cable applications
- Single-piece housing for simplified installation and reduced component count
- Compatible with copper conductors: 4/0 AWG stranded or 250 kcmil solid
- Accommodates cable insulation diameters from 1.090 inch to 1.310 inch
- Field-proven design for underground and industrial power distribution
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 4/0 STR AWG , 250 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 25PCJ1K2270 |
Size | 14-3/8 inch long |
Size | 1.090 inch to 1.310 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.5000 L |
Package Weight (Metric) | 1.1340 kg |

25PCJ1J2270
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
69TCJS4-4-4Q
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, - 4Q
25PCJ2J1270-H1230
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
69TCJS1R240PGAGNN
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size R. Copper Connector. 40P. G G A G N N
69TCJS1QB42PNLNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper/no connector required, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69TCJS44B54P00LNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 54P - Conductor Diameter Range - 1.648-1.746 inch (41.86-44.35mm), Heatsink Size 0 - not included, Heatsink Bore - 0 - not included. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
15PCJ2N1410-M1400
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.
15PCJ2N1410-L1380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.Frequently Asked Questions
Can copper connectors be used on aluminum conductors?
No, copper connectors should not be used on aluminum conductors. An all-copper connector is only suitable for splicing copper conductors to copper conductors.
What is the primary use of PCJ power cable joints?
PCJ power cable joints are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil.
Where can PCJ power cable joints be installed?
PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications. They provide a permanent, fully shielded, and fully submersible splice.
What are the two styles of PCJ power cable joints?
Style 1 has a single-piece housing for straight splicing. Style 2 has a universal housing with separate cable adapters for transition splicing of different cable sizes.
What voltage classes are available for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What conductor types and sizes are compatible?
PCJ power cable joints can be used with copper or aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.
What pull force can the interlock withstand?
The pin-and-socket interlock of the PCJ power cable joints is designed to withstand a pull force of up to 500 lb.
What safety standards do PCJ joints meet?
The shield design meets IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.
What is the continuous current rating?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
What is the short-time current rating?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
How to Install the 15/25/35PCJ1 Series Straight Joint
This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for aluminum or copper conductors in wire-shielded cables.
Estimated time: 2h
Tools needed:
Wire-brush, Crimping tool, T&B WT3D tool (for cable ties, 35kV only), Wire strippers, Cutting tool
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Connector (User Supplied, for grounding wires), DELTECt Cable ties (TYD5135, for 35kV ONLY), No. 14 AWG copper wire or equivalent (if shield wires are smaller)
- De-energize Apparatus and Inspect Parts
Before starting, ensure all apparatus is de-energized and locked out. Do not touch or move energized products in the work area. Inspect all package contents for completeness and damage. Verify all components, including the joint housing and splice, are rated correctly and compatible with the cable and mating products. Failure to follow these safety instructions can result in serious or fatal injury.
- Prepare Cables for Joint Centerline
Overlap both cables and precisely cut them to 12 inches (305mm) from the intended centerline of the joint, ensuring sufficient shield wire length for rejoining. If applicable, remove the cable jacket from Cable 1 to 37 inches (940mm) and from Cable 2 to 21 inches (530mm). Carefully fold back the shield wires on both cables. Finally, make a clean cut on both cables exactly at the joint centerline.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1's insulation shield to a length between 1/2 inch (13mm) and 1-1/2 inches (38mm). Thoroughly clean and lubricate the insulation shield. Apply lubricant to the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage, ensuring no contamination of electrical interfaces.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2. Refer to the provided table for precise dimensions: for 500-750 MCM, remove insulation to 2 1/2 inches ('Y') and shield to 6 1/4 inches ('X'); for 1000 MCM, remove insulation to 2 3/8 inches ('Y') and shield to 6 3/8 inches ('X'). DO NOT cut or nick the cable insulation or conductor during this critical step.
- Install and Crimp the Splice
If using aluminum conductors, wire-brush them immediately before insertion into the splice. Insert the conductors into the splice and check the dimension against the 'Max Check Before' table (6 inches for 500-750 MCM, 6 7/8 inches for 1000 MCM); if it exceeds this, redo the assembly. Crimp the splice according to its specific recommendations. Wipe off all excess inhibitor. Verify the distance between cable insulations against the 'Max Check After' table (6 1/4 inches for 500-750 MCM, 6 1/2 inches for 1000 MCM); if it exceeds this, redo the assembly. Remove any sharp protrusions or burrs from the crimped splice and ensure all metal chips/filings are cleared from the assembly area.
- Lubricate Cables for Housing Slide
Clean the cable surfaces where indicated in the installation diagrams. Apply lubricant in the direction of the arrows to create a gradual build-up or ramp of lubricant at the edge of the insulation shield on both cables. This preparation facilitates the smooth and proper sliding of the joint housing into its final position.
- Complete Joint Assembly and Grounding
Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY, install two DELTECt Cable ties on each end of the cable entrance: the outer tie approximately 1/4 inch (6mm) from the splice edge, and the second tie 1/4 inch (6mm) from the first with offset locking heads. Use a T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and securely attach them to the ends of the joint as shown. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and all remaining shield wires using an appropriate user-supplied connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing to complete the installation.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.