Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1N1320 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.

ABB Installation Products 35PCJ1N1320 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786515653


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 35kV Power Cable Joint, SKU 35PCJ1N1320, is engineered for reliable termination of single-conductor, shielded power cables in medium-voltage distribution systems. Designed specifically for aluminum conductors sized at 450 AWG stranded, this Style 1 joint accommodates a cable insulation diameter range of 1.515 to 1.780 inches, ensuring compatibility with a wide range of cable specifications. The single-piece housing design simplifies installation by eliminating multiple assembly steps, reducing potential error points and saving valuable field time during deployment in substations, industrial facilities, and utility networks. This joint is rated for 35 kV, meeting the requirements for safe and efficient operation in medium-voltage applications. The robust construction provides a secure electrical connection while maintaining environmental sealing, which is crucial for preserving system integrity in demanding operational environments. The material compatibility with aluminum conductors ensures optimal conductivity and long-term performance, minimizing the risk of degradation over time. Proper installation according to manufacturer guidelines is essential for achieving the specified performance ratings and ensuring the longevity of the power cable system. This product is a key component for maintaining the operational continuity of electrical infrastructure requiring high-voltage power transmission, offering a dependable solution for critical power distribution applications.
  • 35 kV Voltage Rating
  • Single Piece Housing for simplified installation
  • Accommodates Cable Insulation Diameter: 1.515 - 1.780 inches
  • Designed for 450 AWG Stranded Aluminum Conductors
  • ABB Installation Products Manufacturer

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
450 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
15-3/4 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500. Copper Conductor. Conductor Size AWG Stranded 450.

25PCJ1L2330-2320

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500. Copper Conductor. Conductor Size AWG Stranded 450.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1K2270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, - 4Q

69TCJS4-4-4Q

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, - 4Q
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

25PCJ2J1270-H1230

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size R. Copper Connector. 40P. G G A G N N

69TCJS1R240PGAGNN

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size R. Copper Connector. 40P. G G A G N N
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper/no connector required, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1QB42PNLNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper/no connector required, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 54P - Conductor Diameter Range - 1.648-1.746 inch (41.86-44.35mm), Heatsink Size 0 - not included, Heatsink Bore - 0 - not included. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package

69TCJS44B54P00LNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 54P - Conductor Diameter Range - 1.648-1.746 inch (41.86-44.35mm), Heatsink Size 0 - not included, Heatsink Bore - 0 - not included. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.

15PCJ2N1410-M1400

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.

Frequently Asked Questions

What voltage classes are PCJ power cable joints available in?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the continuous current rating for PCJ power cable joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

Can aluminum connectors be used for copper-to-copper connections?

No, an all-copper connector is required for copper-to-copper connections. The kit's aluminum compression connector is for aluminum-to-aluminum or aluminum-to-copper.

What is the AC withstand for a 25 kV PCJ joint?

For a 25 kV class PCJ joint, the AC withstand at 60 Hz for 1 minute is 52 kV.

What is the BIL impulse withstand for a 35 kV PCJ joint?

For a 35 kV class PCJ joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 300 kV.

What is the short-time current rating for PCJ power cable joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating up to 35 kA.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.

What pull force can the PCJ joint interlock withstand?

The pin-and-socket interlock of the PCJ power cable joint can withstand a pull force of up to 500 lb.

What cable types are PCJ power cable joints designed for?

They are designed for UD cable with concentric neutral and extruded insulation shielding. They also work with fabric-tape shielded or lead-jacketed cables using proper adapters.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

How to Install the 35PCJ1 Series Straight Joint

This guide provides step-by-step instructions for installing the 35PCJ1 series permanent, fully shielded, fully submersible straight joint for wire shielded cables. It covers cable preparation, splice installation, and final assembly for aluminum or copper conductors.

Estimated time: 2h

Tools needed:

Cable cutting tool, Cable jacket removal tool, Insulation removal tool, Tapering tool or utility knife, Wire brush (for aluminum conductors), Crimping tool (specific to splice), Deburring tool, T&B WT3D tool (for 35kV DELTECt Cable ties)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Conductor connector (user supplied), DELTECt Cable ties (for 35kV only), #14 AWG copper wire (if shield wires are smaller), Grounding wire connector, Cable jacket reconstruction material (if applicable)

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation. Do not touch or move energized products. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products.

  2. Prepare Cables for Joint Assembly

    Overlap both cables and cut them to 12 inches (305mm) from the center line of the joint to ensure sufficient length for shield wires. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the center line of the joint.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1, pushing it up to the shield wires for temporary storage.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the specified dimensions for your conductor size (e.g., 'Y' and 'X' dimensions). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.

  5. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Crimp the splice following the manufacturer's recommendations provided with it. Wipe off any excess inhibitor. Remove any sharp protrusions or burrs generated during crimping, ensuring all metal chips are cleared from the splice and joint assembly area. Clean the cables where indicated and lubricate them to create a build-up at the edge of the insulation shield.

  6. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch from the splice edge, with an offset of locking heads. Use a T&B WT3D tool to tighten. Remove and discard the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the ends of the joint. Insert one shield wire from each cable (if #14 AWG or larger, otherwise use #14 AWG copper wire) through the joint grounding eye. Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket over both cables and the joint housing where applicable.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.