Authorized ABB Distributor (Installation Products)
ABB - Installation Products 675LRTP-G2220-DRG - 900 Amp, DeadBreak, 15KV, Stick Op Elbow Kit, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products 675LRTP-G2220-DRG 900 Amp, DeadBreak, 15KV, Stick Op Elbow Kit, Cable Insulation Diameter 0.760 inch to…

UPC: 783786443987


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products 900 Amp DeadBreak Stick Operated Elbow Kit, SKU 675LRTP-G2220-DRG, is engineered for medium voltage power distribution systems with a rated voltage of 15KV. This kit is specifically designed for deadbreak applications, allowing for safe connection and disconnection under load without interrupting service. The connector accommodates cable insulation diameters ranging from 0.760 inches to 0.950 inches, ensuring compatibility with a variety of cable types. The kit includes a copper compression lug for secure and reliable conductor termination, providing low-resistance electrical contact and long-term durability. It supports conductor sizes including stranded #2 AWG or solid #1 AWG, with a cross-sectional area equivalent to 33.62 mm². The stick operation mechanism enables remote engagement and disengagement, enhancing safety for utility and industrial maintenance personnel by minimizing exposure to live components. This elbow kit is constructed with high-quality materials to withstand the demands of established electrical infrastructure, ensuring dependable performance in critical power distribution applications. The UNSPSC code for this product is 39121421.
  • 900 Amp current rating
  • 15KV voltage class
  • DeadBreak, Stick Operated Elbow Kit
  • Cable Insulation Diameter: 0.760" - 0.950"
  • Copper Compression Lug for #2 AWG Stranded / #1 AWG Solid conductor

Specifications

Amperage Rating
600 to 200 A
Application
Connect 900 Amp interface to 200 Amp Loadbreak Tap
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Enclosure
Yes, EPDM Rubber
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Reducing Tap Plug 900 to 200 Amps. Provides an External Visible Break by Hotstick Removal of the Elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Stick Op Reducing Tap Plug Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
13.5 IN x 9.25 IN x 8.5 IN
Package Dimensions (L x W x H)
34.29 cm x 23.495 cm x 21.59 cm
Package Weight (Imperial)
0.1000 L
Package Weight (Metric)
0.0450 kg
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.

K655LR-F5220

25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
900 Amp, 25kV, Deadbreak, Stick-Op Connector Kit. Fixed Bolt, Insulated Cap, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

K675LRTPFB-L5270-DRG

900 Amp, 25kV, Deadbreak, Stick-Op Connector Kit. Fixed Bolt, Insulated Cap, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

655LRTP-LM0380-DRG

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
900 Amp, 15kV, Deadbreak, Stick-OP Elbow Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1 or Compacted Solid 1/0 or mmSquared Compact 50. Copper Conductor Only.

675LRTP-K2320

900 Amp, 15kV, Deadbreak, Stick-OP Elbow Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1 or Compacted Solid 1/0 or mmSquared Compact 50. Copper Conductor Only.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

656LRTP-G0270

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

656LRTP-K0330

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

655LRTP-J0280-DRG

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. 200ECS Cold-Shrinkable Jacket Seal Included.

655LRTP-J0270-DRG-S

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. 200ECS Cold-Shrinkable Jacket Seal Included.

How to Install the ELASTIMOLD 273/375DRG(3) Insulated Cap with Ground Lead

This guide provides step-by-step instructions for the safe installation of the ELASTIMOLD 273/375DRG(3) Insulated Cap, designed for insulating, shielding, and watersealing loadbreak bushing interfaces.

Estimated time: 30m

Tools needed:

Hotstick

Supplies needed:

ELASTIMOLD 273/375DRG(3) Insulated Cap with Ground Lead, ELASTIMOLD approved lubricant

  1. Connect Electrostatic Grounding Wire

    Connect the free end of the electrostatic grounding wire to the system ground, ensuring enough slack for hot-stick operation of the insulated cap. CAUTION: Train the grounding wire so it does not contact the bushing interface during operation. DANGER: All apparatus must be de-energized during installation or removal of parts, except for test point caps and indicators that can be installed and operated energized.

  2. Prepare Insulated Cap

    Remove the protective cover from the insulated cap. Lubricate the cap's internal mating surface using only the supplied lubricant or ELASTIMOLD approved lubricants. Do not substitute other lubricants, as they may be harmful to this product and its mating products. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when not in use.

  3. Attach Insulated Cap to Bushing

    Firmly attach a hotstick (a minimum length of 8 ft is recommended) to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing. Push the cap home with a fast, firm, straight motion, ensuring it is fully mated with the locking ring seated. Detach the hotstick from the insulated cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.