ABB Installation Products 675ETPSP-L2380 900 Amp, DeadBreak, 15KV, Window-Op Elbow Kit, Cable Insulation Diameter 1.180 inch to…
UPC: 783786395323
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 900 Amp current rating
- 15KV voltage class
- DeadBreak elbow kit with window-open design
- Accommodates cable insulation diameter 1.180" - 1.465"
- Copper compression lug for reliable termination
Specifications
Amperage Rating | 900 A |
Application | 900 Amps, 15kV |
Color | Black |
Conductor Range | 700 to 750 STR/COMPR kcmil , 900 SOL/COMPT kcmil |
Connection | Compression |
Connection Type | Deadbreak |
Current Rating | 900 A |
Insulation | EPDM Rubber |
Material | Copper |
Material | Housing - EPDM-Rubber |
Mounting Type | Window-Op Elbow |
Series | 675ETPSP |
Size | 1.180 inch to 1.465 inch |
Size | Cable Insulation Diameter 1.180 inch to 1.465 inch |
Special Features | Includes Sealing Kit |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Window-Op Connector |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

656CEPT-M5380
15kV, 600 Amp - 200 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter and lug kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
656ETP-K0320DRGSG2-2
600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit withCapacitive Test Point, 15KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 450 /Solid 500/550. 200ECS-G2 Jacket Seal and Grounding Kit Included.
675ETPSP-M2380-DRG
900 Amp, DeadBreak, 15KV, Window-Op Elbow Kit, Copper, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
656ETP-H0270
600 Amp, Dead Break, Elbow Connector, Window-Op Connector Kit with Capacitive Test Point, 15KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
656ETP-M0380-DRG-S
600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit withCapacitive Test Point, 15KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 700/750, Solid 900. 200ECS Jacket Seal Included.
656ETP-K0330DRGSG2-2
600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit withCapacitive Test Point, 15KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300. 200ECS-G2 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
What is the primary function of the 675ETP?
The 675ETP elbow tap plug allows a 200 Amp tap from a mating 900 Amp connector.
What items are included in the 675ETP kit?
Each 675ETP kit contains one bushing insert, one protective shipping cap (1601-APC-1), two lubricants (82-08), and one installation instruction (IS-0766).
How can I verify proper installation of mating components?
The 675ETP includes a Seating Indicator that provides a visual check for properly installed mating components.
Can the loadbreak interface be operated while energized?
Yes, the loadbreak interface of the 675ETP is specifically designed for energized operation.
What is the momentary rating for the deadbreak interface?
The momentary rating for the 900 A deadbreak interface is 25kA Symmetrical for 10 cycles.
What is the continuous current rating for the deadbreak interface?
The 900 A deadbreak interface has a continuous current rating of 900 Amp.
What is the momentary and fault close rating?
The momentary and fault close rating for the 200 A loadbreak interface is 10kA Symmetrical for 10 cycles.
What is the continuous and loadbreak current rating?
The 675ETP has a 200 Amp continuous and loadbreak current rating for its loadbreak interface.
What is the Basic Impulse Level (BIL) withstand rating?
The 675ETP has a 95kV BIL impulse withstand rating, based on a 1.2 x 50 microsecond wave.
What is the maximum phase-to-phase voltage?
The maximum phase-to-phase voltage for the 15kV class is 14.4kV.
How to Install the LINK-C 600 Amp Deadbreak Connector System
This guide provides detailed instructions for the safe installation and initial setup of the LINK-C 600 Amp Deadbreak Cam Link Operable Connector System, covering mounting, wiring, and grounding procedures. Ensure all apparatus are de-energized before beginning installation.
Estimated time: 1h 30m
Tools needed:
Torque wrench (capable of 12 ft-lbs and 50-60 ft-lbs), 600ATM Operating Tool, Hot stick, Wire strippers, Welding equipment (if using mounted stand-off plug option)
Supplies needed:
ELASTIMOLD supplied lubricant, Hex nuts (3/8-16, if using mounted stand-off plug option), Lockwashers (if using mounted stand-off plug option), Studs (3/8-16 x 2", if using mounted stand-off plug option), #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector, 600 amp elbow (pre-installed on cable), Apparatus bushing, Epoxy standoff plug, 600 amp bushing extender, Retainer contact, LINK-C connector, Mating 200 amp product (optional), Alignment bracket (if using alignment bracket option), Bushing extender clamp (supplied with alignment bracket), Elbow clamp (supplied with alignment bracket), Hex bolts and lock washers (supplied with alignment bracket)
- Ensure Safety and Prepare Components
WARNING: All apparatus must be de-energized during installation. Confirm all components are complete, undamaged, and compatible with the cable and mating products. Have all required tools and supplies at hand, and maintain cleanliness throughout the procedure. If retrofitting from a Stick-Op or Bolted Link, refer to the Retrofit Supplement on page 7 of the original documentation before proceeding to Step 4 of these instructions.
- Install the 600 Amp Elbow onto the Cable
Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure it will align correctly with the stand-off plug or apparatus bushing.
- Install Mounted Stand-Off Plug (If Applicable)
If using a mounted stand-off plug, weld three 3/8-16 x 2” studs to the faceplate according to customer standard practice and specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Install the stand-off plug over the studs, resting on the nuts or spacers. Secure with lockwashers and hex nuts, tightening to 12 ft-lbs torque. Verify the top surfaces of the bushing and stand-off plug are in-line.
- Prepare Bushing Extender and Elbow Assembly
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM Operating Tool into the retainer contact, engage the internal hex broach, and thread into the apparatus bushing, torquing to 50-60 ft-lbs. Similarly, clean and lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow. Install the elbow onto the epoxy standoff plug, insert the 600ATM Operating Tool into the retainer contact, and thread into the epoxy standoff plug, torquing to 50-60 ft-lbs.
- Install Alignment Bracket (If Applicable)
If using an alignment bracket, remove the bushing extender clamp and elbow clamp from the bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight. Position the elbow in the alignment bracket, aligning the elbow cuff evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight. Ensure the elbow clamp notch faces the cable entrance.
- Install the LINK-C Connector
Clean and thoroughly lubricate both 600 ampere interfaces of the LINK-C connector with ELASTIMOLD supplied lubricant. Align the LINK-C connector so it is perpendicular to the switch faceplate when inserted. Insert the LINK-C connector into the bushing extender and elbow, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick to move the lever arms downward, engaging the roller pin and moving the LINK-C connector inward until the lever arms are perpendicular to the alignment bracket leg.
- Ground the System and Install Mating Products
Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the LINK-C connector. Ground, then install the desired mating product on the 200 amp interface according to its specific installation instructions. Ground the cable: if using concentric neutral cable, twist the wires together and connect to ground; if using 20MA or 21MA grounding devices, connect the ground lead to ground. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.