Authorized ABB Distributor (Installation Products)
ABB - Installation Products 656RETP-M0380-DRG - 600 Series Elbows with IEE Conductor Size AWG or kcmil, Compressed Stranded 1000. E 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Replacement Elbow Connector Kit. Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

ABB Installation Products 656RETP-M0380-DRG 600 Series Elbows with IEE Conductor Size AWG or kcmil, Compressed Stranded 1000. E 386…

UPC: 783786532018


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 600 Series Elbow Connector Kit, SKU 656RETP-M0380-DRG, is designed for reliable 15kV applications with a 600 Amp rating. This kit features IEE conductor size compatibility for compressed stranded conductors ranging from AWG or kcmil 1000, and compacted solid conductors from 900 kcmil. It is specifically engineered for cable insulation diameters between 1.370 inches and 1.630 inches. The kit includes E 386 Capacitive Test Points for essential diagnostic functions and an insulated cap for safety and protection. The integrated aluminum compression lug ensures a secure and robust connection. This connector is suitable for test and ground replacement operations in electrical distribution systems. Manufacturer: ABB - Installation Products. UNSPSC Code: 26121630.
  • 15kV Voltage Rating
  • 600 Amp Current Rating
  • Compatible with 1.370" to 1.630" Cable Insulation Diameter
  • Includes E 386 Capacitive Test Points
  • Aluminum Compression Lug for Stranded/Solid Conductors

Specifications

Application
15 kV, 600 Amps
Connection
Compression
Material
Aluminum
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Elbow with Test Point
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.

K655BLR-K0330

600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.
Connector Assembly, includes Tin Plated Copper Crimp Connector Ground Probe for cable size 4/0 STR/COMPR, 3-1/2 inch long, Probe is 2 inch long x 3/8 inch Diameter. Tin Plated Copper 1-Hole Lug for 4/0 Conductor Length 4.06 inch wight 1 inch wide Pad. Pad has 2nd Hole that is 15/64 inch Diameter in Corner of Pad. Flexible Cable Cut Length 27.5 inch, 2/0 Rope Lay Tinned Copper.

750-71

Connector Assembly, includes Tin Plated Copper Crimp Connector Ground Probe for cable size 4/0 STR/COMPR, 3-1/2 inch long, Probe is 2 inch long x 3/8 inch Diameter. Tin Plated Copper 1-Hole Lug for 4/0 Conductor Length 4.06 inch wight 1 inch wide Pad. Pad has 2nd Hole that is 15/64 inch Diameter in Corner of Pad. Flexible Cable Cut Length 27.5 inch, 2/0 Rope Lay Tinned Copper.
Direct Test Elbow, 35kv, 600 Amp Dead Break

756BDLR

Direct Test Elbow, 35kv, 600 Amp Dead Break
15/25kv, Rod Contact for 16THG Terminators, includes Contact Rod, Ground Strap and Rain Cap. Conductor size - 2/0 Stranded/Compressed or 3/0 Compact/Solid.

16TCA-0250-4

15/25kv, Rod Contact for 16THG Terminators, includes Contact Rod, Ground Strap and Rain Cap. Conductor size - 2/0 Stranded/Compressed or 3/0 Compact/Solid.
Direct Test Elbow, 35kv, 600 Amp Dead Break

755BDLR

Direct Test Elbow, 35kv, 600 Amp Dead Break
600 Series Elbows with IEE Conductor Size AWG or kcmil, Compressed Stranded 1000. E 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Replacement Elbow Connector Kit. Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

656RETP-L0330-DRG

600 Series Elbows with IEE Conductor Size AWG or kcmil, Compressed Stranded 1000. E 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Replacement Elbow Connector Kit. Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 35kV, Deadbreak, RetroFit Cam-Op Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.

755LINK-CLRN0380ADRG

600 Amp, 35kV, Deadbreak, RetroFit Cam-Op Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.
15/25kV, Contact Assembly for 655CETP (ComboT Elbow Reducing Tap Plug). Length 5.8 inch. Includes Insulator Tube, Star Washer, Tulip Contact, Stop Ring.

655-64

15/25kV, Contact Assembly for 655CETP (ComboT Elbow Reducing Tap Plug). Length 5.8 inch. Includes Insulator Tube, Star Washer, Tulip Contact, Stop Ring.

How to Install the Elastimold LINK-C Deadbreak Connector System

This guide provides step-by-step instructions for the safe and proper installation of the Elastimold LINK-C Deadbreak Cam Link Operable Connector System. It covers mounting, connecting, and grounding procedures for high voltage electrical equipment.

Estimated time: 1h 30m

Tools needed:

Torque wrench, Suitable tool for 1 inch hex (e.g., socket or wrench), Hot stick, Wire strippers, Crimping tool, Welding equipment (if applicable), Cleaning rags

Supplies needed:

ELASTIMOLD supplied lubricant, 3/8-16 x 2 inch studs (3, if applicable), Hex nuts (6), Lockwashers (3), Spacers (optional), Hardware for alignment bracket (supplied with bracket), #14 AWG or #12 AWG solid copper wire, Appropriate ground connectors, 600 amp elbow (with its own installation instructions), Epoxy standoff plug (if applicable), Mating 200 amp product (with its own installation instructions)

  1. Prepare for Installation and Ensure Safety

    DANGER: Before beginning, ensure all apparatus is de-energized. Inspect all components for damage, proper rating, and compatibility with mating parts. Gather all required tools and supplies. Read these instructions completely. WARNING: This installation must be performed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Install the 600 Amp Elbow onto the Cable

    Install the 600 amp elbow onto the cable according to the separate installation instructions provided with the elbow. Ensure the elbow is positioned such that it will align correctly with the stand-off plug or apparatus bushing.

  3. Mount the Stand-Off Plug (If Applicable)

    If your installation requires a bolted stand-off plug, weld three 3/8-16 x 2 inch studs to the equipment faceplate according to the specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it is in-line with the apparatus bushing. Place the stand-off plug over the studs, resting on the nuts or optional spacers. Secure the stand-off plug by installing a lockwasher and hex nut on each of the three studs, then tighten to 12 foot-pounds torque. Verify that the top surfaces of the apparatus bushing and stand-off plug are in-line.

  4. Install the Bushing Extender and Elbow

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender using ELASTIMOLD supplied lubricant. IMPORTANT: Bushing extender interfaces must be thoroughly lubricated to allow for proper removal of the link. Install the bushing extender onto the apparatus bushing. Insert the 600ATM tool into the retainer contact, engage the internal hex broach, and then insert the retainer contact into the bushing extender. Thread it into the apparatus bushing using a suitable tool applied to the 1 inch hex portion of the 600ATM, torquing to 50-60 ft-lbs. Next, clean and lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600ATM tool into the retainer contact, engage the internal hex, and insert the retainer contact into the 600 amp elbow through the compression lug hole. Thread it into the epoxy standoff plug, torquing to 50-60 ft-lbs.

  5. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender, measuring 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket using the supplied hardware (hex bolt and lock washer). Torque the bolts by alternating sides until the clamp tabs are flush with each other and tight on both sides.

  6. Position and Secure the Elbow in the Bracket

    Carefully position the elbow within the alignment bracket, ensuring the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket using the supplied hardware. Torque the bolts by alternating sides until the clamp tabs are flush with each other and tight on both sides. Verify that the elbow clamp notch faces the cable entrance of the elbow.

  7. Install the LINK-C Connector

    Clean and thoroughly lubricate both 600 ampere interfaces of the LINK-C connector with ELASTIMOLD supplied lubricant. IMPORTANT: Interfaces must be thoroughly lubricated to allow for proper removal of the link. Align the Link such that when inserted into the bushing extender and elbow, the Link is perpendicular to the switch faceplate. Insert the Link into both the bushing extender and the elbow, making sure both lever arms are positioned on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing the Link inward, use a hot stick eye to move the lever arms downward, thus engaging the roller pin and moving the Link inward. Continue moving the lever arms until they are perpendicular to the alignment bracket leg.

  8. Ground the System

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twisting it tight, and connecting it to a reliable ground point. Clean and lubricate the 200 amp interface on the Link. Ground and then install the desired mating product onto the 200 amp interface, following its specific installation instructions. Ground the cable: if using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector; if using 20MA or 21MA grounding devices, connect the ground lead from the device to ground using a suitable connector. For three-phase installations, connect all grounds from all three phases to a common ground point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.