ABB Installation Products 656RETP-L0330-DRG 600 Series Elbows with IEE Conductor Size AWG or kcmil, Compressed Stranded 1000. E 386…
UPC: 783786532032
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating with 600A current capacity
- E 386 capacitive test points for safe voltage detection without de-energizing cables
- Compatible with compressed stranded conductors (AWG 500 to kcmil 600) and compacted solid conductors (250 mm² to 300 mm²)
- Supports cable insulation diameters from 1.180 inch to 1.465 inch
- Aluminum compression lug with insulated cap for corrosion resistance and environmental protection
Specifications
Application | 15 kV, 600 Amps |
Connection | Compression |
Material | Aluminum |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Elbow with Test Point |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655BLR-K0330
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.
755LINK-CLRN0380ADRG
600 Amp, 35kV, Deadbreak, RetroFit Cam-Op Connector Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.
655-64
15/25kV, Contact Assembly for 655CETP (ComboT Elbow Reducing Tap Plug). Length 5.8 inch. Includes Insulator Tube, Star Washer, Tulip Contact, Stop Ring.
676RETPSP-L2330-DRG
900 Amp, 15/25kV, Deadbreak, Repair Elbow, Factory Assembled Stud, which is not field removable. Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
21MA-H
Grounding Rod Adapter Assembly, Size H - Insulation Diameter Range .850 to 1.050 inch. includes Silicone Lubricant, Molded Housing, Grounding Rod and Instruction Sheet.
21MA-L
Grounding Rod Adapter Assembly, Size L - Insulation Diameter Range 1.180 to 1.465 inch. includes Silicone Lubricant, Molded Housing, Grounding Rod and Instruction Sheet.
16TCA-1240-4
15/25kv, Rod Contact for 16THG Terminators, includes Contact Rod, Ground Strap and Rain Cap. Conductor size - 1/0 Stranded/Compressed or 2/0 Compact/Solid.
655BE
600 Amp, 15kV, Deadbreak, Bushing Extender Length 8.4 inch, Diameter 3.1 inch, with Tin Plated Aluminum Stud Length 2.215 inch with 5/8-11 UNC-2A Threads on Both Ends.How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the safe and proper installation of the LINK-C 600 amp deadbreak cam link operable connector system, including component assembly, lubrication, and grounding procedures.
Estimated time: 2h
Tools needed:
Hot stick, 600ATM Operating Tool, Torque wrench, Wire strippers, Suitable tool for 1-inch hex portion
Supplies needed:
ELASTIMOLD supplied lubricant, No. 14 AWG or No. 12 AWG solid copper wire, Appropriate ground connector, Mounting hardware for alignment bracket
- Ensure Safety and Prepare Components
DANGER: Before beginning, ensure all apparatus is de-energized. Verify all package contents are complete and undamaged, and check components for proper fit. Read all instructions thoroughly, have all required tools at hand, and maintain cleanliness throughout the procedure. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.
- Install Cable Elbow
Install the 600 amp elbow onto the cable according to the specific installation instructions provided with the elbow. Ensure the elbow is positioned to properly align with the standoff plug or apparatus bushing.
- Install Bushing Extender
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender using ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM tool into the retainer contact, engage the internal hex broach, and then insert the retainer contact into the bushing extender. Thread the retainer contact into the apparatus bushing using a suitable tool applied to the 1-inch hex portion of the 600ATM, and torque to 50-60 ft-lbs.
- Install Elbow onto Standoff Plug
Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow using ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600AMT tool into the retainer contact, engage the internal hex broach, and then insert the retainer contact into the 600 amp elbow through the hole in the compression lug. Thread the retainer contact into the epoxy standoff plug using a suitable tool applied to the 1-inch hex portion of the 600AMT, and torque to 50-60 ft-lbs.
- Mount Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender, ensuring it is 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush with each other and tight on both sides.
- Secure Elbow with Clamp
Position the elbow within the alignment bracket so that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket using the supplied hardware. Torque by alternating sides until the clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Connect the Link
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted. Insert the Link into both the bushing extender and the elbow, ensuring both lever arms are positioned on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick to move the lever arms downward, engaging the roller pin and moving the Link inward. Continue moving the lever arms until they are perpendicular to the alignment bracket leg.
- Complete Grounding and Mating Product Installation
Ground the elbow by feeding a No. 14 AWG or No. 12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground and then install the desired mating product onto the 200 amp interface according to its specific installation instructions. Ground the cable: if using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector; if using 20MA or 21MA grounding devices, connect the ground lead to ground with a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.