ABB Installation Products 167ELR-6689-210 15kV 200 Amp, Loadbreak Repair Elbow Connector, Cable Insulation Diameter 0.665 inch to…
UPC: 783786624782
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Fully rated 15kV, 200 Amp Class loadbreak elbow connector
- Extended length housing and compression lug (+3-1/4" / 82.6 mm) for short cables
- Meets ANSI/IEEE Standard 386, 95kV BIL rating
- Supports 200 Amp continuous and loadbreak operation; 10kA Sym momentary/fault close
- Fully shielded, submersible, 100% peroxide-cured insulation
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | #2 SOL/COMPT AWG |
Connection | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 11.7 in |
Length | 297.18 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 3-1/4 inch (82.6mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Repair Elbow Connector |
Voltage Rating | 15 kV |
Width | 7.1 in |
Width | 180.34 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.1000 L |
Package Weight (Metric) | 1.4060 kg |

167ELR-6689-5210
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Seal
274ELR-88110-240
25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
168ELR-88110-230
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
168ELR-6689-210
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
167ELR-6689-220-240
200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact.
273ELR88110230240270
200 Amp, 25kV, Loadbreak Repair Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor size 230-240-270.
167ELR-7495-250-260
15 kV, 200 Amp Loadbreak Repair Elbow without Test Point. Cable Insulation Diameter 0.740 to 0.950 inch. 2/0 Stranded/Compressed or 3/0 Solid/Compact to 3/0 Stranded/Compressed or 4/0 Solid/Compact .
655LINKCLRK0330ADRG
600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.Frequently Asked Questions
What is the catalog number for the test point cap?
The catalog number for the test point cap is 156-7.
Where are these Elastimold elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.
What material are the elbow connectors made from?
The connectors are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
What standards do these elbow connectors comply with?
They are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
What conductor sizes are compatible with these connectors?
These connectors are compatible with conductor sizes ranging from #2 AWG to 250 kcmil.
What safety features do these connectors offer?
They feature dead-front construction, EPDM rubber for controlled gas release, a non-stick interface, and a robust stainless steel pulling eye.
What are the voltage and current ratings?
These loadbreak elbow connectors are rated for 15/25 kV voltage class and 200 amp current.
How much longer are the repair and replacement elbows?
The repair elbow is 3 1/4 inches longer, and the replacement elbow is 8 7/8 inches longer than standard elbows.
What is the primary use of these elbow connectors?
These elbow connectors facilitate transitioning from live-front to dead-front equipment, addressing varying bushing heights and insufficient cable length without splicing.
What is the catalog number for the test point cap?
The catalog number for the test point cap is 156-7.
How to Install Elastimold 167ELR/168ELR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the new installation and total replacement of Elastimold 167ELR and 168ELR loadbreak elbow connectors on UD cable, including cable preparation, elbow assembly, and grounding procedures.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Pin wrench, Wire brush, Crimp tool, Wire strippers, Cutting tool, Measuring tape or ruler, Hotstick (insulated live-line tool)
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), UD Cable, Copper wire (No. 14 AWG / 2.5mm), Appropriate ground connector, HV insulated cap(s) or connector(s), Silicone grease (for 168ELR test point cap)
- Train and Cut Cable
Train the UD cable as shown in the documentation to ease operation, ensuring a minimum of 20 inches extends beyond the end of the cable pad mount transformer. For new installations, cut any excess cable squarely at the center line of the bushing. For replacements, remove the old probe using a pin wrench, pull the old elbow off with a twisting motion, and cut off the old compression lug. DANGER: Ensure all apparatus is de-energized before starting any cable work to prevent serious or fatal injury.
- Prepare Cable End and Install Lug
Unwrap and bind the concentric neutral wires 'X' inches back from the end of the cable (e.g., 13 inches for 02200XXX, 02500XXX, 02509XXX compression lugs). Carefully remove the insulation shield and insulation from the cable end, cutting squarely and taking extreme care not to nick the conductor or insulation. Wire brush the bare aluminum conductors immediately. Install the compression lug onto the conductors, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable. Remove the insulation shield for a length of 10 inches and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble Elbow and Probe
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. CAUTION: DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product(s). Keep insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating sufficient torque.
- Connect Neutral to Ground
Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all the concentric neutral wires together with the copper wire from the grounding eye. Connect this assembly to ground using an appropriate connector. Provide adequate slack in the wires to allow for future elbow operation.
- Connect Elbow to Bushing
DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. WARNING: DO NOT OPERATE BY HAND. Use a full insulated 'hotstick' type live-line tool for this operation. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact (arc follower portion) into the bushing until the first slight resistance is felt. WARNING: Do not hold the elbow in this position. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to ensure the internal lock is fully engaged.
- Test Voltage (168ELR Only)
If using a 168ELR connector, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the suitable sensing device made for use with separable connectors manufactured with capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or use of the wrong measuring equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it tightly on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.