ABB - Installation Products 655CETP-N0380-S - 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. With Shrink-Fit Jacket Seal Kit. Aluminum Compression Lug, 700/750 kcmil Stranded/Compressed or 900 kcmil Solid/Compact.

ABB Installation Products 655CETP-N0380-S 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test…

UPC: 075114378833


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655CETP-N0380-S is a 600 Amp, 15kV Combo T Elbow Reducing Tap Plug designed for medium-voltage power distribution systems. This aluminum component provides a reliable 200 Amp tap off a mating 600 Amp connector, enabling safe and efficient loadbreak operations in energized systems. The product features a reducing design to accommodate cable insulation diameters from 1.515 inches to 1.780 inches, with compatibility for 700/750 kcmil stranded/compressed or 900 kcmil solid/compact conductors via an aluminum compression lug. The included Shrink-Fit Jacket Seal Kit ensures a watertight and dust-tight environmental seal, protecting against moisture and contaminants in challenging industrial environments. The tap plug meets ANSI/IEEE Standard 386 with a maximum phase-to-ground operating voltage of 8.3kV and phase-to-phase voltage of 14.4kV. It supports a 95kV BIL impulse withstand, 34kV AC one-minute withstand, and 53kV DC 15-minute withstand. The loadbreak interface is rated for 200 Amp continuous and loadbreak operations, with a 10kA symmetrical momentary and fault close rating. Installation requires the 600ATM assembly tool, and the product includes a hex-broach for proper torque application. The peroxide-cured insulation and jacket provide long-term durability. This tap plug is designed for use with mating products including 167DR, 167DRG, 167ESA-XX, 165LR, 165LRJS, 167ELR, 167RLR, 167DLR, 167DELR, and 160GLR. The red color aids in visual identification and system organization.
  • 600 Amp, 15kV rated Combo T Elbow Reducing Tap Plug
  • Accommodates cable insulation diameters from 1.515" to 1.780"
  • Supports 700/750 kcmil stranded/compressed or 900 kcmil solid/compact conductors
  • Includes Shrink-Fit Jacket Seal Kit for environmental protection
  • Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand rating

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - PDM Rubber
Special Features
Reducing Tap Plug with Stud, Cable Adapter, and Lug
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656L2-M0380

600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
Solenoid Valve Connectors, Accessory, ISB gasket

V-GP1B

Solenoid Valve Connectors, Accessory, ISB gasket
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 1/0 or Compacted/Solid 2/0.

K656I-H0240

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 1/0 or Compacted/Solid 2/0.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-L0300-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included. Comes with Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation Instructions and Crimp Chart

K151SR-B0220-SG3

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included. Comes with Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation Instructions and Crimp Chart
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed/Stranded 3/0, Solid/Compact 4/0 /mmSquared 85.01. 200ECS-G3 Jacket Seal and Grounding Kit Included. Comes with Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

376LR-K5260-SG3

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed/Stranded 3/0, Solid/Compact 4/0 /mmSquared 85.01. 200ECS-G3 Jacket Seal and Grounding Kit Included. Comes with Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact. No Sealing Kit.

274FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch, Bi-Metal Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact. No Sealing Kit.
600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 1.550 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1000.

K656LRTP-N0410-DRG

600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 1.550 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1000.

Frequently Asked Questions

What is the maximum voltage rating for this tap plug?

The ABB 655CETP-N0380-S has a maximum voltage rating of 15kV.

What is the current carrying capacity of this ABB tap plug?

This tap plug is rated for a continuous current of 600 Amps.

What cable insulation diameter range does this tap plug support?

The tap plug is designed for cable insulation diameters between 1.515 inches and 1.780 inches.

What conductor sizes can the aluminum compression lug accommodate?

The aluminum compression lug is suitable for 700/750 kcmil stranded/compressed or 900 kcmil solid/compact conductors.

Does this tap plug include a seal for environmental protection?

Yes, the 655CETP-N0380-S comes with a Shrink-Fit Jacket Seal Kit for robust environmental sealing.

What material is the ABB 655CETP-N0380-S tap plug made from?

The tap plug is constructed from aluminum.

How to Install 655/656/675/676CETP Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and wiring of 655/656/675/676CETP Deadbreak Elbow Connectors, ensuring proper cable preparation, lug crimping, and connection to mating apparatus. Follow all safety warnings for high voltage equipment.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Wire brush, 600AT or 600ATM assembly tool (torque tool), Hotstick, Suitable voltage sensing device, Wire strippers, Utility knife, Measuring tape or ruler

Supplies needed:

655/656/675/676CETP Elbow, Cable Adapter, Compression Lug, Lubricant (silicone grease), Vinyl Plastic Tape, Tape Retainer (if applicable), Tape Marker (if applicable), 10TL cable shield adapter (if applicable), No. 14 AWG Copper wire (or equivalent) for grounding, Suitable ground connector, HV insulated cap(s) or connector(s), DR(G), ESA, GLR, or LR (if using tap plug interface)

  1. Perform Pre-Installation Checks and Safety Procedures

    DANGER: All apparatus must be de-energized during installation. Inspect all parts for damage, rating, and compatibility. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors. Check package contents for completeness. Gather all required tools and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Position Cable and Make Initial Cut

    Position the cable in its final assembled location, ensuring enough slack for elbow removal. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable and Remove Outer Jacket

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires. Remove the outer jacket to the dimension shown in the product's detailed diagrams. If using a 20MA/21MA grounding device or 600ECS Jacket Cable Seal, refer to their specific instructions for jacket removal and shield connection.

  4. Prepare Cable Shield (Type-Specific)

    Follow the instructions applicable to your cable type: fold back shield wires; remove flat metallic tape shield and secure with vinyl plastic tape; remove fabric tape shield and install tape retainer and marker; remove longitudinally corrugated shield and install tape marker; for UNISHIELD® or lead sheath cable, refer to 10TL cable shield adapter instructions; remove semi-con shield and install tape marker. Do not cut or nick the cable insulation.

  5. Bevel Insulation and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation (using supplied lubricant), working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor and Verify Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution to avoid cutting or nicking the cable adapter or the conductor. Verify that the exposed conductor length is between 4-3/8 inches and 4-11/16 inches (111mm-119mm). If not, redo the assembly.

  7. Install and Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the lug. Measure the 'Check Dimension' before crimping (must be less than 6-1/2 inches / 165mm). Crimp the lug according to its supplied instructions. Wipe off any excess inhibitor. Verify the distance from the lug end to the cable adapter is 6-1/2 to 7-1/4 inches (165mm-184mm) after crimping.

  8. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  9. Prepare Mating Apparatus and Install Stud

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from both the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  10. Connect Elbow to Mating Part

    Push the elbow onto the mating part. For products dated September 30, 2013, or earlier, use the 600AT assembly tool to engage the hex broach and torque the contact assembly until the torque limiter ratchets (19-25 ft/lbs). For products dated October 1, 2013, or later, use the 600ATM assembly tool and tighten the contact assembly to 50-60 ft/lbs torque, but do not exceed 60 ft/lbs.

  11. Ground Cable Shield and Elbow

    Insert one end of a No. 14 AWG Copper wire (or equivalent ampacity) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. Ensure the cable shield is grounded according to grounding device instructions or an alternate method. It is recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  12. Install Tap Plug Interface (Optional)

    If using a tap, clean and lubricate the entire loadbreak interface and the DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface, following the specific instructions provided with those products.

  13. Verify Seating and Perform Voltage Test

    Confirm complete assembly by ensuring no portion of the colored interface sleeve is visible when viewed from the side. If applicable, perform a voltage test using the integral capacitance test point. Remove the test point cap with a hotstick (peel off at an angle). WARNING: This is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. Clean, lubricate, and replace the cap after testing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.