The ABB 35kV Power Cable Joint Style 1 (SKU: 35PCJ1L) is engineered for reliable and secure termination of medium-voltage power cables. This single-piece housing joint is designed to accommodate cable insulation diameters ranging from 1.180 inches to 1.465 inches, ensuring a precise fit for a variety of cable constructions within the 35 kV class. The Style 1 design simplifies installation while maintaining the integrity of the cable's insulation system under operational stress. This joint is crucial for maintaining the continuity and safety of power distribution networks, preventing electrical faults and ensuring uninterrupted power flow. Its robust construction is built to withstand the electrical and environmental demands typical of industrial and utility power systems. The precise sizing capability ensures minimal air voids and optimal electrical field control, which are critical for preventing premature failure in high-voltage applications. ABB's commitment to quality in their Installation Products division means this joint is manufactured to exacting standards, providing a dependable connection point for your critical infrastructure. When specifying cable accessories for 35 kV systems, the 35PCJ1L offers a straightforward and effective solution for cable splicing and termination needs, directly addressing the insulation diameter requirements for optimal performance and longevity. This product is essential for electrical contractors, utility maintenance crews, and industrial plant engineers responsible for the installation and upkeep of medium-voltage power distribution systems.
  • 35 kV Voltage Rating for medium-voltage applications
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 1.180 to 1.465 inches
  • Style 1 design ensures secure and reliable cable joint
  • Manufactured by ABB - Installation Products

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.8900 L
Package Weight (Metric)
0.8570 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch.

35PCJ1M

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 450.

15PCJ1K2320

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 450.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1H1270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

25PCJ1G1230

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

25PCJ1H1250

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

25PCJ1G1250

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.

15PCJ1K1320

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 500.

35PCJ1N2330

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 500.

Frequently Asked Questions

What material are PCJ cable joints made from?

Elastimold PCJ power cable joints use permanently crimped connectors inside ethylene propylene diene monomer (EPDM) rubber housings.

Are PCJ joints compatible with fabric-tape or lead-jacketed cables?

Yes, PCJ joints work with fabric-tape shielded or lead-jacketed cables when used with the proper Elastimold cable shield adapter or grounding device.

What type of connector is included in the N1 kit?

The N1 kit includes an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.

What is the short-time current rating of PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What safety standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings.

What pull force can the PCJ joint withstand?

The pin-and-socket interlock of the PCJ power cable joint is designed to withstand a pull force of up to 500 lb.

Is taping required for PCJ cable joint installation?

No, the cable entrance engages the insulation shielding of the cable, which eliminates the need for taping during installation.

What type of cable is PCJ designed for?

PCJ power cable joints are designed for use with UD cable that has concentric neutral and extruded insulation shielding.

What conductor materials are compatible with PCJ joints?

PCJ power cable joints can be used with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides step-by-step instructions for installing the 15/25/35PCJ1 series straight joint, a permanent, fully shielded, and submersible joint for wire shielded cables, suitable for aluminum to aluminum and/or aluminum to copper conductors.

Estimated time: 2h

Tools needed:

Wire Strippers, Measuring Tape, Utility Knife, Wire Brush, Crimping Tool, T&B WT3D Tool (for 35kV installations)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Electrical Connector (for grounding wires), DELTECt Cable Ties (TYD5135, for 35kV installations), #14 AWG Copper Wire (or equivalent, if needed for grounding)

  1. De-energize and Inspect Apparatus

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Failure to follow these instructions will result in serious or fatal injury. Inspect all parts for damage, proper rating, and compatibility with mating parts before beginning installation. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Prepare Cables for Joint Installation

    Overlap both cables and cut them to 12 inches (305mm) from the joint centerline to ensure sufficient shield wire length. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Cut both cables precisely at the joint centerline.

  3. Prepare Cable 1 and Store Joint Housing

    Taper the edge of Cable 1's insulation shield from 1/2 inch (13mm) to 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it back until it rests against the folded shield wires.

  4. Prepare Cables for Splice and Remove Insulation

    Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the 'X' and 'Y' dimensions provided in the documentation for your conductor size. Next, carefully remove the insulation shield from both cables, again using the specified 'X' and 'Y' dimensions. WARNING: Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this step.

  5. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Before crimping, check the dimension of the inserted conductors against the 'Max Check Before' table in the documentation. If it exceeds the maximum, re-do the assembly. Crimp the splice securely, following the manufacturer's recommendations provided with the splice. After crimping, wipe off any excess inhibitor.

  6. Final Splice Preparation

    Check the distance between the cable insulations against the 'Max Check After' table. If it exceeds the maximum, re-do the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips or filings are removed from the splice and joint assembly area. Clean the cables where indicated and lubricate them in the direction of the arrows to create a lubricant build-up at the edge of the insulation shield.

  7. Position Joint Housing

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the splice edge, and the second ties approximately 1/4 inch (6mm) from the first, with an offset of the locking heads. Use the T&B WT3D tool (not included) to tighten and trim the ties. For 35kV installations ONLY: Remove and discard the yellow pin from the joint grounding eye.

  8. Grounding and Finalization

    Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat this for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Where applicable, reconstruct the cable jacket over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.