ABB Installation Products 25PCJ1G2230 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786624379
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Single-piece housing for simplified installation and reduced labor time
- Compatible with 25kV systems and cable insulation diameters from 0.760" to 0.950"
- Supports copper conductors #1 AWG stranded or solid 1/0 AWG
- Includes housing, connector, lubricant, installation instructions, and crimp chart
- Ideal for power distribution networks, substations, and industrial facilities
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | #1 STR AWG , 1/0 SOL AWG |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Material | Copper conductor, polymer housing |
Number Of Conductors | 2 |
Series | 25PCJ1 |
Size | 14-3/8 inch long |
Size | 0.760-0.950" insulation diameter, #1/Solid 1/0 AWG |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.7500 L |
Package Weight (Metric) | 0.7940 kg |

25PCJ2J1230-G1230
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1J2290
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Solid 350.
15PCJ1K2330
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 500.
15PCJ1G1260
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
15PCJ1M2380
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 750.
35PCJ1L1270
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ1K1300
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
35PCJ1N2380
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.Frequently Asked Questions
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.
What type of connector is included for aluminum conductors?
The kit includes an aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.
What is the corona extinction voltage for a 35 kV class joint?
For a 35 kV class joint, the corona extinction voltage at 3 pC sensitivity is 30 kV.
What is the BIL impulse withstand for a 25 kV class joint?
For a 25 kV class joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 150 kV.
What voltage classes are available for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What types of cable splicing can PCJ joints perform?
PCJ power cable joints can perform straight splicing of two similar cables or transition splicing of different cable sizes.
Where can Elastimold PCJ power cable joints be installed?
They can be installed in direct-burial, underground vault, and overhead applications. They provide a permanent, fully shielded, fully submersible splice.
What conductor types and sizes are compatible with PCJ joints?
PCJ power cable joints are compatible with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.
What pull force can the pin-and-socket interlock withstand?
The pin-and-socket interlock in PCJ power cable joints is designed to withstand a pull force of up to 500 lb.
What safety standards do PCJ power cable joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
How to Install the 15/25/35PCJ1 Series Straight Joint
This guide provides step-by-step instructions for the permanent installation of the 15/25/35PCJ1 series straight joint, designed for wire shielded cables with aluminum or copper conductors. It covers cable preparation, splice installation, and final joint assembly.
Estimated time: 2h
Tools needed:
Wire brush (if aluminum conductors), T&B WT3D tool (for 35kV installations), Wire strippers, Utility knife, Crimping tool
Supplies needed:
Conductor connector, DELTECt Cable ties TYD5135 (for 35kV installations), No. 14 AWG copper wire (or equivalent, if shield wires are smaller than #14 AWG), Grounding wire connector, Cable jacket reconstruction material
- Prepare for Installation and Ensure Safety
Before starting, ensure all apparatus is de-energized and the work area is safe. This product must be installed by competent personnel trained in high-voltage electrical equipment safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Gather all required tools and maintain a clean work environment throughout the procedure.
- Prepare Cable Lengths and Remove Jacket
Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline to ensure sufficient shield wire length. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the joint's centerline.
- Taper Cable 1 and Position Joint Housing
Taper the edge of Cable 1's insulation at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires.
- Remove Cable Insulation and Shield
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process. Refer to the provided dimensions "X" and "Y" for precise removal lengths based on conductor size (e.g., 500-750 MCM or 1000 MCM).
- Install and Crimp the Conductor Splice
If conductors are aluminum, wire-brush them thoroughly before immediately inserting them into the splice. Crimp the splice according to the manufacturer's recommendations provided with the splice. Wipe off any excess inhibitor. Verify the distance between cable insulations; if it exceeds the "Max Check After" dimension from the table, redo the assembly. Remove any sharp protrusions or burrs created during crimping and ensure all metal chips/filings are cleared from the splice and joint assembly area before proceeding. Clean the cables where indicated and lubricate in the direction of the arrows to create a lubricant build-up at the edge of the insulation shield.
- Finalize Joint Assembly and Grounding
Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY, install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the splice edge and then 1/4 inch (6mm) from the first with offset locking heads. Use the T&B WT3D tool to tighten and trim the ties. For 35kV ONLY, remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.