ABB Installation Products 16THG-GA-1230-4 Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain…
UPC: 783786643899
Documents & Media
Contact for Pricing
Minimum Qty: 15
Multiplier: 15
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Single Piece Terminator (Class 1)
- Includes Contract Rod, Ground Strap, and Rain Cap
- Rated for 15/25kV systems
- Accommodates cable insulation diameter: .775 to .885 inches
- For Aluminum conductors: #1 Stranded/Compressed or 1/0 Compact/Solid
Specifications
Application | Used in Switchgear and Padmounted Transformers |
Color | Gray |
Connection | Slide-On |
Material | Aluminum |
Material | EPDM-Rubber Housing |
Size | Complete unit 22 inches long |
Standard | IEEE 48-1975 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Single-Piece Terminator |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.0000 L |
Package Weight (Metric) | 1.3610 kg |

K655BLR-K0330
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.
00700210
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #2 - Compact/Solid
00700260
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 3/0 - Stranded/Compressed, 4/0 Compact/Solid, Carries Current, made in USA
00700220
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #2 - Stranded/Compressed, #1 Compact/Solid
16THG-HA-0270-4
Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .980 to 1.115 inches, Conductor size -4/0 Stranded/Compressed.
00700250
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 2/0 - Stranded/Compressed, 3/0 Compact/Solid
00700230
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #1 - Stranded/Compressed, 1/0 Compact/Solid
00700200
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #4 - Stranded/Compressed, #3 Compact/SolidHow to Install the 16THG Single-Piece Outdoor Terminator
This guide provides step-by-step instructions for the safe and correct installation of the 16THG Single-Piece Outdoor Terminator, including cable preparation, component assembly, and grounding procedures.
Estimated time: 1h 30m
Tools needed:
Cable cutting tool, Wire strippers, Plastic electrical tape, Approved safety solvent, Wiping cloth, Measuring tape or ruler, Wire brush (for aluminum conductors), Crimping tool (with appropriate dies for -4 style connector)
Supplies needed:
16THG Rubber Housing, Conductor Contact (appropriate for cable size), Rubber Cap, Ground Strap, Plain Washer, Lubricant (supplied or ELASTIMOLD approved), No. 14 AWG (2,5mm2) copper wire
- De-energize Apparatus and Train Cable
DANGER: Ensure all apparatus is de-energized before beginning installation. Train the cable into position. Unwrap and fold back concentric wires 15 inches (380mm) from the end of the cable. Secure these concentric wires at this point by wrapping with plastic electrical tape or a strand of wire (do not use a concentric neutral wire). Twist the loose concentric wires together to form a ground lead.
- Remove Cable Insulation
Carefully cut and remove the insulation from the end of the cable. For No. 6 thru 1/0 Str. conductors, remove 1 7/8 inches (47.6mm). For No. 1 thru 4/0 Str. conductors, remove 3 3/4 inches (95.9mm). Avoid nicking or damaging the conductor strands. If the conductor is damaged, cut the end off and restart this step.
- Remove Extruded Cable Insulation Shield
Carefully cut and remove the exposed extruded cable insulation shield a distance of 9 inches (229mm) from the end of the insulation. Cut the shield squarely, ensuring not to nick or cut the cable insulation. If insulation is damaged, cut off and restart. Bevel the edge of the cable insulation not more than 1/4 inch (6.4mm).
- Clean Cable Insulation
Thoroughly clean the outer jacket and insulation to remove all traces of semi-conducting residue. Use a rag soaked with an approved safety solvent, wiping from the end of the cable toward the outer jacket. Failure to remove all conductive residue will cause product failure.
- Mark Extruded Shield and Protect Conductor
Mark the extruded cable insulation shield by wrapping a piece of tape exactly 1 inch (25.4mm) from its end. To prevent the cable conductor from damaging the inside of the terminator, wrap a piece of tape around the leading edge of the conductor. Damage to inner surfaces can result in unsatisfactory performance.
- Apply Lubricant to Cable and Terminator
Before proceeding, verify that the cutback and taping from Steps 3 and 5 are correct. Apply the supplied lubricant or an ELASTIMOLD approved lubricant sparingly to the cable insulation and to the inside base surface of the terminator. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product.
- Slide Terminator Housing onto Cable
Slide the terminator housing down onto the cable using a spiral motion. Ensure the base of the terminator housing aligns with the wrap of tape on the extruded cable insulation shield. The top of the terminator housing should be flush with the end of the cable insulation. Improper positioning can lead to unsatisfactory performance.
- Verify Terminator Housing Position
Check the dimension from the top of the terminator housing to the end of the cable conductor. Refer to Table 1 in the documentation for the correct dimension based on the contact being used. If the housing is not aligned with the tape, not flush with the cable insulation, or the check dimension is incorrect, remove the housing and re-check Steps 3 and 5 before proceeding.
- Prepare and Install Conductor Contact and Washer
Completely remove the wrap of tape from the cable conductor. If using aluminum conductor, wire brush the bare conductors. Place the plain washer over the bared conductor. Immediately slide the conductor contact onto the conductor. For Universal Rod Contacts with .840” or .938” OD Barrels, apply lubricant sparingly to the inside of the rubber cap and the outside of the conductor contact before sliding the cap onto the contact. Carefully clean any excess inhibitor from the area around the top of the terminator.
- Crimp Conductor Contact
Beginning at the upper (or top) crimp mark on the contact, start the first crimp. Crimp towards the terminator, rotating each successive crimp 90˚ or 180˚. Hold the contact tightly, pushing down towards the plain washer during crimping. Refer to the crimp chart for the -4 style crimp barrel packaged with the contact.
- Seat Rubber Cap
If using Universal Rod Contacts with .840” or .938” OD Barrels, check the position of the terminator cap to ensure it did not move during crimping; reposition if necessary. If using Universal Rod Contacts with .625” OD Barrels, carefully wipe excess inhibitor from the contact and terminator housing after crimping, then apply supplied lubricant sparingly to the inside of the rubber cap and the outside of the conductor contact. Slide the rubber cap down the contact so it is fully seated and the groove in the bottom of the cap snaps into place over the matching ring on the top of the terminator housing.
- Make Takeoff Connection
Make the takeoff connection on the universal rod contact as desired, ensuring all connections are secure and meet local electrical codes.
- Install Grounding Clamp and Connect Ground Lead
If the terminator is not bracketed, place the grounding clamp around the terminator base, directly under the shoulder and above the projecting rib (1/2 inch / 12.7mm dimension). Remove the marking tape and wipe off any grease on the cable. Insert a separate No. 14 AWG (2.5mm2) copper wire or equivalent into the crimp lug supplied with the ground strap and crimp. Do not use one of the twisted concentric neutral wires. Connect the loose end of the No. 14 AWG wire to the concentric neutral wires on the cable and securely connect the twisted concentric neutral wires to ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.