Authorized ABB Distributor (Installation Products)
ABB - Installation Products 274FLR1-D0260 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 3/0 AWG Stranded Compressed, 4/0 AWG Solid Compact, No Sealing

ABB Installation Products 274FLR1-D0260 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…

UPC: 075114254687


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274FLR1-D0260 molded current limiting fuse housing is a compact medium-voltage solution engineered for precise fault protection in industrial and utility applications. Rated for a nominal fuse voltage of 15.5kV, this housing accommodates cable insulation diameters from 0.890 inch to 1.220 inch (25-31mm) and supports aluminum conductor sizes including 3/0 AWG stranded compressed and 4/0 AWG solid compact. The unit features two capacitive test ports for safe voltage verification without system interruption, enabling maintenance teams to perform diagnostics without de-energizing critical circuits. Optimized for space-constrained installations, the 274FLR1-D0260 is ideal for integration into switchgear, transformers, and distribution panels where compact form factors are essential. The absence of sealing ensures compatibility with existing systems that do not require environmental protection, reducing installation complexity and cost. The housing’s small-profile design prioritizes ease of installation and maintenance while maintaining structural integrity in high-voltage environments. Manufactured by ABB - Installation Products, the 274FLR1-D0260 supports primary fuse holders (2) and secondary fuse clips (1), with an insulation system rated at 105°C and a temperature rise of 55°C. Key applications include medium-voltage motor starters, transformers, and distribution panels in industrial facilities, utilities, and commercial power systems. The 274FLR1-D0260 is a critical component for systems requiring reliable fault protection and diagnostic capabilities in compact installations.
  • Rated for 15.5kV nominal fuse voltage
  • Accommodates 25-31mm cable insulation diameters
  • Supports 3/0 AWG stranded compressed and 4/0 AWG solid compact aluminum conductors
  • Two capacitive test ports for safe voltage verification without system interruption
  • Compact design with 105°C insulation system and 55°C temperature rise

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Material
Molded, Aluminum
Series
274FLR1
Size
Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Voltage Rating
15.5 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-5260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

168AFLR3-C0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

168AFLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

168AFLR3-B0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
8.3 kV, 200 Amp, Fuse LoadBreak Elbow, Two Direct Test Points, Small Housing, Cable Insulation Diameter 0.890-1.220 inches, Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact, With Sealing Kit.

168AFLR1-D5240-S

8.3 kV, 200 Amp, Fuse LoadBreak Elbow, Two Direct Test Points, Small Housing, Cable Insulation Diameter 0.890-1.220 inches, Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact, With Sealing Kit.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

168AFLR1-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal, Conductor size 250 - 2/0 AWG Stranded Compressed, 3/0 AWG Solid/Compact.

168AFLR1-C5250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal, Conductor size 250 - 2/0 AWG Stranded Compressed, 3/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

168AFLR1-C0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

Frequently Asked Questions

What are the applications of the 274FLR Fused Elbow?

The 274FLR protects light duty underground distribution systems, sub-loops, and radial taps by combining full-range current-limiting fusing with loadbreak elbow switching.

Is the fuse included with the 274FLR elbow connector?

No, the fuse for the 274FLR elbow connector must be ordered separately.

Are sealing and grounding kits recommended for the 274FLR?

Yes, for safety purposes, a sealing and grounding kit is highly recommended with the loadbreak elbow.

What items are included in the 274FLR kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, lubricant tubes, installation instructions, a crimp chart, and a V.D Cap-Peroxide.

Does the 274FLR have a built-in test point?

Yes, the 274FLR has built-in voltage test points for quick and convenient blown fuse indication.

How is fuse replacement handled for the 274FLR?

The 274FLR features a split center section designed for easy fuse replacement.

What are the key features of the 274FLR Fused Elbow?

Key features include full-range current-limiting fusing, hot stick operable switching, full sealing with ECS kits, and built-in voltage test points for blown fuse indication.

What is the symmetrical interrupting capability?

The symmetrical interrupting capability of the 274FLR is 50,000 Amps.

What is the current rating of the 274FLR?

The current rating for the 274FLR is 6-20 Amps.

What is the nominal fuse voltage for the 274FLR?

The nominal fuse voltage for the 274FLR is 16.2kV (Phase to Ground) for the 25/28kV voltage class.

How to Install the 274FLR Loadbreak Fused Elbow Connector

This guide provides comprehensive instructions for the safe and proper installation of the 274FLR Loadbreak Fused Elbow Connector, covering cable preparation, component assembly, and final connection to a bushing.

Estimated time: 2h

Tools needed:

Probe Wrench, Allen Wrench (torque limiting, supplied), Wire brush, Crimp tool, Hotstick (for operation)

Supplies needed:

274FLR Cable Half Housing, 274FLR Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant (supplied), No. 14 AWG / 2.5mm copper wire (or equivalent), Appropriate grounding connector, Optional: 200ECS Cold Shrink Cable Seal

  1. Prepare Cable for Termination

    DANGER: Ensure all apparatus is de-energized before beginning installation. Using the bushing centerline as a reference, cut excess cable, leaving a minimum of 20 inches beyond the bushing. Slide the optional 200ECS Cold Shrink Cable Seal onto the cable if used. Remove the cable jacket for the length of “A” (fuse body length) plus 7-3/8 inches from the bushing centerline. Unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of “A” from the bushing centerline, leaving a minimum of 7-3/8 inches of cable to terminate.

  2. Prepare Cable End and Install Compression Lug

    Cut 1-1/8 inches from the cable end, ensuring a square cut and avoiding nicks to the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Refer to the crimp chart provided with the lug. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Lubricate and Assemble Cable Half Housing

    Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. Do not substitute lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface “A” of the housing.

  4. Install Fuse and Probe Connector

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand-tighten it into the cable connector. CAUTION: The fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse. Assemble the probe connector to the fuse terminal. Rotate the probe connector so its flats are perpendicular to the mating bushing. Lock the probe connector in position and tighten the setscrews using the special torque-limiting Allen wrench supplied. Rotate the cable half of the Fused Elbow so that its test point is perpendicular to the flats on the probe connector.

  5. Assemble Elbow Half Housing and Probe

    Apply lubricant to the elbow half of the fused elbow. Assemble the elbow half to the cable half, ensuring the cuff of the cable half overlaps the elbow half by 3/4 inch. Verify that the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector. Push on the cable if necessary to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread. Tighten the probe using the special torque-limiting Allen wrench supplied; insert the short end and tighten until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it. DO NOT OVERTIGHTEN.

  6. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eyes. If used, finish installing the 200ECS jacket seal. Twist all neutral wires and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  7. Connect Fused Elbow to Bushing Plug

    DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate the connection using a full insulated "hotstick" type live-line tool as per operating instructions. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.