ABB - Installation Products 168FLR3-A5220 - 15kV, 200 Amp, Loadbreak Fused Elbow (Full Range Current Limiting), with Test Point, Cable Insulation Diameter .575-.740 inches, Bi-Medal Lug, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid. No Sealing Kit. Large Housing for Fuse Size and Voltage Range 60-80 Amps 8.3 kV and 3-45 Amps 17.2 kV.

ABB Installation Products 168FLR3-A5220 15kV, 200 Amp, Loadbreak Fused Elbow (Full Range Current Limiting), with Test Point…

UPC: 075114321723


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR3-A5220 Loadbreak Fused Elbow delivers full-range current limiting protection for 15kV underground distribution systems. Rated at 200 Amps, this device is engineered for medium-voltage applications including underground residential distribution (URD) systems, pad-mounted transformers, and switching cabinets where reliable fault protection and loadbreak operation are critical. Key specifications include a bi-metal lug compatible with #2 AWG stranded compressed or #1 AWG compact/solid conductors, accommodating cable insulation diameters from 0.575 to 0.740 inches. The integrated test point enables safe voltage verification without de-energizing the system, enhancing operational safety and maintenance efficiency. The full-range current limiting fuse provides protection across two voltage ranges: 60-80 Amps at 8.3 kV and 3-45 Amps at 17.2 kV. The large housing accommodates fuse sizes within these ranges while maintaining compatibility with standard loadbreak interfaces. The bi-metal lug ensures compatibility with both copper and aluminum conductors, reducing installation complexity and material costs. The absence of a sealing kit allows for direct burial or vault installations where environmental sealing is provided by external components, offering flexibility in system design and deployment. Ideal for medium-voltage applications requiring robust fault protection and loadbreak capability.
  • 15kV voltage rating with 200 Amp current capacity
  • Bi-metal lug compatible with #2 AWG stranded compressed or #1 AWG compact/solid conductors
  • Integrated test point for safe voltage verification without system de-energization
  • Large housing accommodates fuse sizes within specified voltage/current ranges

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
8.3kv Fuse Elbow 200 Amp, Loadbreak With Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact. 200ECS-G3 Jacket Seal and Grounding Kit Included.

168FLR1-A5230-SG3

8.3kv Fuse Elbow 200 Amp, Loadbreak With Sealing Kit, Cable Insulation Diameter 0.575 inch - 0.740 inch / 14.61-18.80mm, BI Metal Connector Only, #1 Stranded/Compressed or 1/0 Solid/Compact. 200ECS-G3 Jacket Seal and Grounding Kit Included.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal, Conductor size 220 - 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

168FLR1-A5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal, Conductor size 220 - 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal, Conductor size 180 - 6 AWG Stranded/Compressed

168FLR1-A5180

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal, Conductor size 180 - 6 AWG Stranded/Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Lug, 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Cold Shrinkable Jacket Seal.

274FLR3-C5240-S

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Lug, 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Cold Shrinkable Jacket Seal.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid/Compact.

168AFLR3C0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

168AFLR3-A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

274AFLR1-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

Frequently Asked Questions

What is the DC 15-minute withstand voltage rating?

The DC 15-minute withstand voltage rating for the 168FLR Fused Elbow is 53kV DC.

What is the AC one-minute withstand voltage rating?

The AC one-minute withstand voltage rating for the 168FLR Fused Elbow is 34kV AC.

What is the frequency rating of the 168FLR Fused Elbow?

The 168FLR Fused Elbow has a frequency rating of 50/60 Hz.

What items are included in each 168FLR Fused Elbow kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, four tubes of lubricant, installation instructions, and a crimp chart.

What type of conductors are compatible with the bi-metal compression lug?

The bi-metal compression lug with a universal aluminum barrel is suitable for both copper and aluminum conductors.

What standards does the 168FLR Fused Elbow meet?

The 168FLR Fused Elbow meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47, Latest Revision.

How is a blown fuse indicated on the 168FLR Fused Elbow?

The 168FLR Fused Elbow has built-in voltage test points for quick and convenient blown fuse indication.

What is the impulse withstand rating for this product?

The impulse withstand (BIL) rating for the 168FLR Fused Elbow is 95kV (1.2 x 50 microsecond wave).

What is the primary application of the 168FLR Fused Elbow?

The 168FLR combines full-range current-limiting fusing with 15kV hot stick operable, loadbreak elbow switching to protect light duty underground distribution systems. It replaces existing 200 Amp loadbreak tap elbows.

Can the 168FLR Fused Elbow be used in submersible environments?

Yes, the 168FLR Fused Elbow is fully sealed and submersible. It also insulates, shields, and eliminates exposed live parts.

How to Install the 168FLR/274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 168FLR or 274FLR Loadbreak Fused Elbow Connector. Ensure all apparatus are de-energized before starting installation to prevent serious or fatal injury. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Allen Wrench (torque limiting), Wire brush, Crimp tool, Wire strippers, Hotstick (for final connection/operation)

Supplies needed:

168FLR or 274FLR kit (Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant), UD Cable, No. 14 AWG / 2.5mm Copper Wire, Optional 200ECS Cold Shrink Cable Seal

  1. Perform Initial Safety Checks and Inspection

    DANGER: Ensure all apparatus are de-energized during installation. Inspect all parts for damage, proper rating, and compatibility with mating components. Check package contents for completeness and ensure all components fit properly with the cable and/or mating products. Read all instructions before proceeding.

  2. Prepare the Cable for Termination

    Using the bushing centerline as a reference, cut excess cable, leaving at least 20 inches beyond the bushing. If using an optional 200ECS Cold Shrink Cable Seal, slide it onto the cable. Remove the cable jacket for the required length (20 inches minimum plus 'A' + 7-3/8 inches from the bushing centerline). Unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable at distance 'A' (11-1/2 inches for FLR-1, 15-3/4 inches for FLR-3), leaving a minimum of 7-3/8 inches of cable to terminate.

  3. Prepare the Cable End and Install Compression Lug

    Cut 1-1/8 inches from the cable end, ensuring a square cut without nicking the conductor. Wire brush the bare aluminum conductors immediately. Install the compression lug onto the conductor, rotating it to spread the inhibitor. Crimp the unthreaded end of the compression lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end by 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Lubricate and Insert Cable into Cable Half Housing

    Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. DO NOT SUBSTITUTE LUBRICANT. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. This allows the fuse to be tightened before bottoming on the rubber.

  5. Install and Tighten the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse. CAUTION: The fuse stud will fracture if over torqued. After hand tightening, pull the housing up against the bottom of the tightened fuse.

  6. Assemble and Position the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Half and Probe, Secure with Hose Clamp

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4 inch. Ensure the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector; it may be necessary to push on the cable to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread the probe. To tighten, use the special torque-limiting allen wrench supplied; insert the short end into the hole in the probe and tighten until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it. DO NOT OVERTIGHTEN.

  8. Connect the Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eyes. If a 200ECS jacket seal was used, finish installing it. Twist all neutral wires together, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  9. Prepare for Final Connection to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. IMPORTANT: Lubricate ONLY IF the transformer and elbow are known to be DE-ENERGIZED. The elbow is now ready for connection to the bushing plug using a hotstick, following appropriate operating instructions. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.