ABB - Installation Products 15PCJ2K1300 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

ABB Installation Products 15PCJ2K1300 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786415250


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 15kV Power Cable Joint, SKU 15PCJ2K1300, is designed for reliable electrical connections in medium-voltage applications. It features a Style 2 joint configuration with a universal housing, accommodating a wide range of cable insulation diameters from 1.090 inches to 1.310 inches. The kit includes separate cable adapters, ensuring a precise fit for your specific cable setup. This joint is engineered for use with aluminum conductors of size 350 AWG stranded. The ABB Installation Products division provides robust solutions for power distribution infrastructure. This joint is suitable for industrial facilities, substations, and other environments requiring secure and insulated power cable terminations. Its construction prioritizes electrical integrity and ease of installation, facilitating efficient maintenance and operational uptime. The universal housing simplifies inventory management by supporting multiple cable sizes within its specified range. Ensure proper application and installation according to manufacturer guidelines for optimal performance and safety. UNSPSC Code: 39121452.
  • 15kV voltage rating for medium-voltage power distribution.
  • Style 2 joint configuration with universal housing.
  • Accommodates cable insulation diameters from 1.090" to 1.310".
  • Includes separate cable adapters for precise fitting.
  • Designed for 350 AWG stranded aluminum conductors.

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
350 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
21 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.0300 L
Package Weight (Metric)
0.0140 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.

15PCJ1G2300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

15PCJ2M1380-K1310

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ2M1330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

25PCJ2P1410

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 550 /Solid 650.

15PCJ2M1380-L1340

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 550 /Solid 650.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

35PCJ1J2240

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ1G1240-1220

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

15PCJ2M1380-J1300

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

Frequently Asked Questions

What voltage classes are available for PCJ power cable joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the short-time current rating for PCJ power cable joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the minimum and maximum cable insulation diameter for a 15PCJ-1 joint with symbol 'F'?

For a 15PCJ-1 joint with symbol 'F', the minimum cable insulation diameter is 0.640 inches and the maximum is 0.820 inches.

What type of connector is needed for copper-to-copper cable connections?

An all-copper compression connector is required for copper-to-copper connections. Copper connectors should not be used on aluminum conductors.

What is the AC withstand voltage for a 25 kV class joint?

For a 25 kV class PCJ joint, the AC withstand voltage at 60 Hz for 1 minute is 52 kV.

What is the DC withstand voltage during installation for a 15 kV class joint?

For a 15 kV class PCJ joint, the DC withstand voltage during installation is 56 kV.

What is the continuous current rating for PCJ power cable joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What is the maximum pull force the pin-and-socket interlock can withstand?

The pin-and-socket interlock in PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What types of cable installations are suitable for PCJ joints?

PCJ power cable joints are designed for permanent, fully shielded, and fully submersible splices in direct-burial, underground vault, and overhead applications.

What are the two styles of PCJ power cable joints used for?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

How to Install the 15PCJ2K1300 Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and fully submersible installation of the 15PCJ2K1300 straight joint for aluminum and/or copper conductor, wire shielded cables. Ensure all safety precautions are followed.

Estimated time: 2h

Tools needed:

Stripping guide, Hex wrench, Wirebrush, Crimping tool

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars, Hose Clamp, Electrical Tape, Appropriate connector (for grounding wires), #14 AWG copper wire (if needed), Heat/cold shrink kit (for cable jacket reconstruction), Bonding cable(s) (if needed), Insulating/sealing tapes (if needed), Solder (if needed), CNW's connectors (if needed)

  1. De-energize and Inspect Cables

    DANGER: All apparatus must be de-energized during installation. Inspect package contents for completeness and damage. Examine both mating cable ends, ensuring they are free from moisture and contaminants. Remove any graphite coatings 12” (30.5cm) beyond the cable jacket cut, avoiding sanding.

  2. Prepare Cable Jackets and Position Housing

    Use the stripping guide to carefully remove the cable jacket of both cables for a distance of 11-1/4” (285.7mm). Fold back shield wires and tape the end of wires on Cable 1 to the jacket, allowing enough extra length to later rejoin over the joint. Clean the surface of the insulation shield, shield wires, and jacket for 30” (760mm). Slide the joint housing onto Cable 1 to a distance of 30” (760mm) and lubricate the 11-1/4” (285.7mm) section.

  3. Prepare Cable Insulation

    Use the stripping guide to carefully remove the insulation shield and cable insulation from both cables. CAUTION: DO NOT CUT OR NICK THE INSULATION, as this could result in assembly failure. Wrap two turns of electrical tape 1” (25mm) from the edge of the insulation shield as a marker on both cables. Clean the cable insulation, then lubricate it to provide a build-up or ramp at the edge of the insulation shield.

  4. Install Cable Adapters

    Take one cable adapter and lubricate the inside of both ends. Install this cable adapter onto Cable 1 until it meets the tape marker. Repeat this process for the other cable adapter on Cable 2.

  5. Install Retaining Collars

    Select a retaining collar and partially thread the proper size setscrews (refer to collar instructions). Position the retaining collar over the insulation and flush against the cable adapter. Using the supplied hex wrench, tighten each set screw only one or two turns at a time to keep the collar centered over the insulation. Continue tightening until the set screws are below the surface of the collar. Repeat for Cable 2.

  6. Install and Crimp Splice

    Clean the ends of the cable adapters and cable. Install the hose clamp around the adapter on the opposite side of the splice from where the housing is stored to hold the adapter in place. Tape over the hose clamp to form a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Ensure the 'Check' dimension does not exceed 8-1/2” (215mm); if it does, redo the assembly. Crimp the splice following its recommendations.

  7. Final Splice Verification and Lubrication

    Wipe off all excess inhibitor from the splice. Check the distance between the cable adapters; if it exceeds 8-3/4” (222mm), redo the assembly. Clean and lubricate the outside surface of the cable adapters before sliding the housing into its final position.

  8. Complete Joint Assembly and Grounding

    Slide the housing into its final position, centering it over the cable adapters. Remove all tape, ensuring cable and adapter insulation are not exposed. Reshape shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent.

  9. Connect Grounding Wires and Reconstruct Jacket

    Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and also over the joint housing. Note that heat/cold shrink materials for this step are not included in the kit and must be supplied by the installer.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.