ABB Installation Products 35PCJ1J2240 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786414628
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV Power Cable Joint, Style 1
- Single-piece housing for simplified installation
- Accommodates cable insulation diameters from 0.980" to 1.180"
- Designed for copper conductors: AWG Stranded 1/0 / Solid 2/0
- Manufacturer: ABB - Installation Products
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 1/0 STR AWG , 2/0 SOL AWG |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 35kV Power Cable Joint Style 1 |
Size | 14-3/8 inch long |
Size | 0.980 inch to 1.180 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.7500 L |
Package Weight (Metric) | 0.7940 kg |

35PCJ2J1240-H1240
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ1G1240-1220
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ2M1380-J1300
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
15PCJ2L2330-K2330
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 500.
115TCJN35144P55KF2NB
115kV, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 3, Housing Size 5 - Bore Diameter 2.550 inch, Insulation Range 2.900-3.290 inch, Connector Type - Aluminum, Conductor Code 44P - 1.276-1.300 inch Diameter, Heatsink Size 55 - 3.000 inch Outside Diameter, Heatsink Bore Diameter K - 1.312 inch, Type Shield F - Corrugated Copper, Metallic Screen Continuity Kit 2 - #2 Flat Braid 12 Foot Long Quantity 2, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
115TCJN4-DP0592567
115 kV, TCJ - Transmission Cable Joint, Housing Type N - Non-Shieldbreak, Housing Style 4 - 57.2mm to 91.96mm (2.25 inch to 3.62 inch)
25PCJ1G2220
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
28PCJ1J
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.980 inch to 1.180 inch.Frequently Asked Questions
What are Elastimold PCJ power cable joints used for?
They are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil. They provide a permanent, fully shielded, fully submersible splice.
What is the AC withstand for a 15 kV PCJ joint?
For a 15 kV class PCJ joint, the AC withstand at 60 Hz for 1 minute is 35 kV.
What is the short-time current rating of PCJ joints?
The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the BIL impulse withstand for a 35 kV PCJ joint?
For a 35 kV class PCJ joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 300 kV.
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for splicing copper conductors to copper conductors only. They should not be used on aluminum conductors.
What type of connector is included in a standard PCJ kit?
A standard kit includes an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors. An all-copper connector is required for copper-to-copper connections.
What safety standards do PCJ power cable joints meet?
The shield design meets the IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What is the pull force rating for PCJ joints?
The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force of up to 500 lb.
What cable types are PCJ power cable joints designed for?
They are designed for use with UD cable with concentric neutral and extruded insulation shielding. They also work with fabric-tape shielded or lead-jacketed cables using proper adapters.
How to Install the 35PCJ1 Series Straight Joint
This guide provides step-by-step instructions for the safe and proper installation of the 35PCJ1 series permanent, fully shielded, and submersible straight joint for wire shielded cables.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Utility knife, Wire brush, Crimping tool, Deburring tool, T&B WT3D tool (for 35kV only)
Supplies needed:
35PCJ1 Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), #14 AWG Copper Wire (or equivalent, if needed), Grounding wire connector, DELTEC Cable ties TYD5135 (for 35kV only)
- Perform Pre-Installation Safety and Inspection
DANGER: Ensure all apparatus are de-energized before beginning installation. Do not touch or move energized products. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Gather all required tools and maintain cleanliness throughout the procedure.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables precisely at the joint's centerline.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1's insulation shield from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the housing onto Cable 1, positioning it up to the shield wires.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor. Refer to the provided 'X' and 'Y' dimensions table for precise removal lengths based on conductor size (e.g., 500-750 MCM, 1000 MCM).
- Install the Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table; if it exceeds, redo the assembly. Crimp the splice according to its manufacturer's recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds, redo the assembly. Remove any sharp protrusions or burrs from the crimped splice and ensure all metal chips/filings are removed from the joint assembly area. Clean the cables where indicated and lubricate them to create a build-up at the insulation shield's edge.
- Complete Joint Assembly
Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTEC Cable ties on each end of the cable entrance, approximately 1/4 inch from the splice edge, with the second tie 1/4 inch from the first and locking heads offset. Use a T&B WT3D tool to tighten and trim ties. Remove and discard the yellow pin from the joint grounding eye. Retrain and secure the shield wires to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.