ABB Installation Products 15PCJ2J2290 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…
UPC: 783786481200
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating for medium voltage applications
- Style 2 joint with universal housing and separate cable adapters
- Accommodates cable insulation diameters from 0.980" to 1.180"
- Designed for AWG 350 solid copper conductors
- Reliable electrical connection and insulation
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 350 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | Style 2 |
Size | 16-3/8 inch long |
Size | 0.980 inch to 1.180 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.5000 L |
Package Weight (Metric) | 1.1340 kg |

15PCJ1G2300
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.
15PCJ1G1270-1240
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
69TCJS1Q240PNDNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
25PCJ2J1240-H1230
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
35PCJ1L2290
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 350.
15PCJ1M2350
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 600 /Solid 700.
15PCJ2J1300-J1270
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35PCJ1L1290
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 350.Frequently Asked Questions
What connector type is used for aluminum to copper splicing?
Kits include aluminum compression connectors suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.
What are the two styles of PCJ power cable joints?
Style 1 is for straight splicing of two similar cables. Style 2 uses separate cable adapters for transition splicing between different cable sizes.
What is the phase-to-ground voltage for the 15 kV class?
For the 15 kV class, the phase-to-ground voltage is 8.7 kV.
What is the continuous current rating for PCJ joints?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
What is the short-time current rating for PCJ joints?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
What voltage classes are available for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What is the BIL impulse withstand for the 35 kV class?
The 35 kV class has a BIL impulse withstand of 300 kV (1.2 x 50 μsec. wave).
What is the corona extinction voltage for the 25 kV class?
For the 25 kV class, the corona extinction voltage is 22 kV with 3 pC sensitivity.
What cable types are compatible with PCJ power cable joints?
They are designed for UD cable with concentric neutral and extruded insulation shielding. They also work with fabric-tape shielded or lead-jacketed cables using proper adapters.
Can copper connectors be used on aluminum conductors?
No, copper compression connectors are suitable for copper-to-copper connections only and should not be used on aluminum conductors.
How to Install the 15/25/35PCJ2WXXXX-RC Straight Joint
This guide provides detailed instructions for installing the 15/25/35PCJ2WXXXX-RC straight joint, a permanent, fully shielded, and submersible joint for aluminum or copper conductor, wire shielded cables. Ensure all safety precautions are followed for high voltage electrical equipment.
Estimated time: 1h 30m
Tools needed:
Hex wrench, Wirebrush, Cable stripping tool, Crimping tool, Wire strippers
Supplies needed:
Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars (2), Hose Clamp, Electrical tape, Appropriate connector (for grounding wires), No. 14 AWG copper wire (or equivalent, if needed for grounding), Heat/cold shrink kit (for cable jacket reconstruction), Bonding cable(s) (if needed), Insulating and sealing tapes (if needed), Solder (if needed), CNW's connectors (if needed)
- Prepare for Installation and Ensure Safety
Before starting, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all kit contents for completeness and damage. Verify proper fit with cable and/or mating products. Examine mating cable ends for moisture or contaminants. Remove graphite coatings 12 inches (30.5cm) beyond the cable jacket cut, avoiding sanding. If strand filled or water-blocking material is present in conductors, consult the cable manufacturer for welding/crimping procedures. Have all required tools at hand and maintain cleanliness.
- Prepare Cable Jacket and Position Housing
Carefully remove the cable jacket of both cables for a distance of 11-1/4 inches (285.7mm) using the stripping guide. Fold back shield wires and tape the end of wires on Cable 1 to the jacket, allowing enough extra length to rejoin over the joint later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30 inches (760mm). Slide the joint housing onto Cable 1 to a distance of 30 inches (760mm).
- Prepare Cable Insulation
Using the stripping guide, carefully remove the insulation shield and cable insulation. DO NOT CUT OR NICK THE INSULATION, as this could result in assembly failure. Wrap two turns of tape 1 inch (25mm) from the edge of the insulation shield as a marker on both cables. Clean the cable insulation, then lubricate it to provide a build-up or ramp of lubricant at the edge of the insulation shield.
- Install Cable Adapters
Take one cable adapter and lubricate the inside of both ends. Install the cable adapter onto the cable until it meets the tape marker, ensuring the insulation extends approximately 5/16 inch beyond the cable adapter. Repeat this process for the other cable adapter on the second cable.
- Install Retaining Collars
Select a retaining collar and partially thread the proper size setscrews (refer to instructions packaged with the collars). Position the retaining collar over the insulation, flush against the cable adapter. Using the supplied hex wrench, tighten each set screw one or two turns at a time to keep the collar centered over the insulation. Continue tightening the set screws until they are below the surface of the collar. Repeat this for Cable 2.
- Splice Conductors and Prepare Housing Area
Thoroughly clean the ends of the cable adapters and the adjacent cable surfaces. Install a hose clamp around the adapter on the opposite side of the splice from where the housing is stored, to hold the adapter in place during final assembly. Tape over the hose clamp to form a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Crimp the splice according to its specific recommendations, ensuring the 'Check' dimension does not exceed 8-1/2 inches (215mm). Wipe off all excess inhibitor. Verify the distance between cable adapters does not exceed 8-3/4 inches (222mm). Clean and lubricate the outside surface of the cable adapters before sliding the housing into its final position.
- Complete Joint Assembly and Grounding
Slide the joint housing into its final position, centering it over the cable adapters. Remove all temporary tape. Ensure that no cable or adapter insulation is exposed after positioning the joint. Reshape the shield wires and secure them to the ends of the joint. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye; repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate user-supplied connector. Reconstruct the cable jacket (where applicable) over both cables and over the joint housing using a heat/cold shrink kit (not included in this kit).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.