ABB Installation Products 35PCJ1L2290 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786491353
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV rated power cable joint
- Single-piece housing design
- Accommodates insulation diameter: 1.180" to 1.465"
- Designed for 350 AWG solid copper conductors
- ABB Installation Products quality
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 350 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | Style 1 |
Size | 14-3/8 inch long |
Size | Cable Insulation Diameter 1.180 inch to 1.465 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

35PCJ1L1290
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 350.
15PCJ1M2350
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 600 /Solid 700.
15PCJ2J1300-J1270
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
69TCJS1Q
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Housing only
69TCJS44B54P4SLFNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 54P - Conductor Diameter Range - 1.648-1.746 inch (41.86-44.35mm), Heatsink Size 4 - Outside Diameter 2.500 inch, Heatsink Bore - S - 1.750 inch. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - F - 4/0 Bonding Cable 6 foot quantity 6 with Split Bolts Quantity 12, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
35PCJ1Q1440-1410
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1250. Aluminum Conductor. Conductor Size AWG Stranded 1000.
69TCJS44B53P5RDNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 53P - Conductor Diameter Range - 1.606-1.647 inch (40.79-41.83mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
69TCJS1R242PNLFNB
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size R. Copper Connector. 42P. N L F N BFrequently Asked Questions
What voltage classes are available for PCJ power cable joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What is the short-time current rating for PCJ joints?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the overall length of a 35PCJ2QX joint?
The 35PCJ2QX joint has an overall length (Dimension A) of 21 inches.
What is the range of cable insulation diameters for 35PCJ-1/2?
For 35PCJ-1/2, the cable insulation diameter can range from a minimum of 0.850 inches (symbol H) to a maximum of 2.120 inches (symbol Q).
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.
Is taping required for insulation shielding during installation?
No, the cable entrance engages the insulation shielding of the cable, eliminating the need for taping.
What is the purpose of the grounding eye on PCJ joints?
The grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing the molded shield at ground potential.
What is the continuous current rating for PCJ joints?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
What safety standards do PCJ power cable joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
Where can PCJ power cable joints be installed?
PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications. They provide a permanent, fully shielded, fully submersible splice.
How to Install the 35PCJ1 High Voltage Cable Straight Joint
This guide provides detailed instructions for the permanent installation of the 35PCJ1 series straight joint, designed for aluminum or copper conductor, wire shielded cables in high voltage applications. It covers cable preparation, splice installation, and final joint assembly.
Estimated time: 2h
Tools needed:
Cable stripping tools, Measuring tape, Tapering tool, Wire-brush (for aluminum conductors), Crimping tool, T&B WT3D tool (recommended for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding), Deltect Cable ties TYD5135 (for 35kV only), #14 AWG copper wire or equivalent (if shield wires are smaller), Cable jacket reconstruction material (where applicable)
- De-energize Apparatus and Inspect Parts
DANGER: De-energize all apparatus in the work area before beginning installation or removal of parts. Do not touch or move energized products. Inspect all components for damage, correct rating, and compatibility with mating parts. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.
- Prepare Cables for Overlap
Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires, then cut both cables at the joint centerline.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends, then slide the housing onto Cable 1 up to the shield wires.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the 'X' and 'Y' dimensions provided in the documentation for your specific conductor size. DO NOT cut or nick the cable insulation or conductor during this process.
- Install the Splice
If conductors are aluminum, wire-brush them and immediately insert them into the splice. Crimp the splice following its manufacturer's recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check Before' and 'Max Check After' dimensions; redo assembly if exceeded. Remove any sharp protrusions or burrs from the crimped splice and clean metal chips/filings from the splice and joint assembly area. Clean and lubricate cables where indicated to build up lubricant at the edge of the insulation shield.
- Complete Joint Assembly
Slide the housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the edge of the splice and approximately 1/4 inch (6mm) from the first, with an offset of the locking heads (T&B WT3D tool recommended). Remove and discard the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, repeating for Cable 2 (if shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent). Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.