ABB Installation Products 15PCJ1L2380 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786437511
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Fully shielded, fully submersible straight splice for 15kV applications
- Accommodates 1.180" to 1.465" cable insulation diameters
- Supports 750 AWG stranded copper conductors
- Rated for continuous current equal to cable rating and short-time current up to 35kA
- Pin-and-socket interlock withstands 500 lbs axial pull force
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 750 kcmil |
Connection | Compression |
Connection Type | Cable Joint |
Insulation | Yes |
Material | EPDM Rubber |
Material | Copper Conductor, Single Piece Housing |
Number Of Conductors | 2 |
Series | 15kV Power Cable Joint Style 1 |
Size | 14-3/8 inch long |
Size | Conductor Size AWG Stranded 750, Insulation Diameter 1.180-1.465 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.5000 L |
Package Weight (Metric) | 1.1340 kg |

15PCJ2N1410-N1380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15PCJ1H1270-1260
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25PCJ1-M2310
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.
25PCJ2N1410-L1330
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
35PCJ1Q
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch.
15PCJ1LM1380
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15PCJ1H2240
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ1J2310
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Solid 500.Frequently Asked Questions
What is the insulation diameter range for this cable joint?
This ABB 15kV power cable joint is designed to accommodate cable insulation diameters ranging from 1.180 inches to 1.465 inches.
What type of conductor is this joint designed for?
This joint is designed for 750 AWG stranded copper conductors.
What is the voltage rating of this ABB cable joint?
This ABB power cable joint is rated for 15kV.
What style of housing does this cable joint feature?
This ABB power cable joint features a Style 1 single-piece housing.
How to Install the 15PCJ1L2380 Single Core Joint
Installation guide for the 15PCJ1L2380 single core joint for extruded solid dielectric cables.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, PVC tape, Cleaning solvent, Clean cloth, Lubricant, Soldering iron or constant force spring tool, Heat gun
Supplies needed:
Joint Housing, Conductor splice, Flat copper braid, Mastic tape, Heat shrink tubing
- Prepare the Cables
Train cables into position and square cut. Remove jackets to specified dimensions. Carefully remove metallic screen and secure ends with PVC tape. Remove non-metallic screen, bevel Cable 1, and cut insulation to 'E' dimension without removing it. Install PVC tape marker on Cable 2 to dimension 'B'.
- Prepare and Store the Joint Housing
Apply PVC tape over the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B'. Lubricate both cable entrances of the splice housing. Clean and lubricate Cable 1 insulation, non-metallic screen, and PVC taped portion. Store the housing onto Cable 1 up to the jacket, ensuring the metallic screen is covered with PVC tape to prevent housing damage.
- Remove Cable Insulation and Install Connector
Remove cable insulation from both cables without nicking. Wire brush exposed conductors. Insert conductors into the conductor splice, ensuring they are fully seated. Crimp the conductor splice according to the provided chart. Remove any sharp protrusions or burrs and clean the area. Wipe off excess inhibitor.
- Clean and Lubricate Core Surfaces
Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, wiping towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant, wiping towards the screen end to create a ramp.
- Install the Joint Housing
Slide the joint housing over the crimp connector into its final position. Ensure the distance 'X' between the joint housing and the PVC tape marker is equal on each side. Remove PVC tape to expose 25mm of copper tape.
- Restore Screen and Outer Jacket
Wrap flat copper braid around each joint housing, overlapping onto the metallic tape screen by 20mm on each side. Attach the braid ends to the metallic tape screen by soldering or using a constant force spring. Lightly sand the outer surface of the jacket on both cables for 130mm and heat for 15 seconds. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it from the center outwards.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.