Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1L2320 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 450.

ABB Installation Products 15PCJ1L2320 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786621286


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 15PCJ1L2320 is a 15kV power cable joint engineered for medium-voltage distribution systems, designed to permanently splice copper conductors sized at 450 AWG stranded with cable insulation diameters ranging from 1.180 to 1.465 inches. This joint meets IEEE Standard 404 for 15kV phase-to-phase voltage, ensuring reliable operation in utility, industrial, and commercial power distribution networks. The single-piece molded rubber housing simplifies installation by eliminating multi-part assembly steps, reducing labor time and potential error points while maintaining dielectric integrity. The fully shielded, fully submersible design withstands pulls up to 500 lbs and is rated for 110kV BIL impulse withstand, 35kV AC withstand, and 70kV DC withstand during manufacture testing. The molded conductive shield provides a virtually indestructible ground shield for true deadfront construction, with a grounding eye for convenient connection. The cable entrance engages the insulation shielding, eliminating the need for taping. Compatible with standard 15kV class cables, including UD cable with concentric neutral or extruded insulation shielding, this joint supports reliable, long-term operation in underground or aerial installations. The 15PCJ1L2320 is part of ABB’s Installation Products line, optimized for field-installable medium-voltage cable terminations where durability and performance are critical.
  • 15kV phase-to-phase voltage rating per IEEE Standard 404
  • Accommodates 450 AWG stranded copper conductors with 1.180-1.465" insulation diameter
  • Single-piece molded rubber housing for simplified installation and reduced error points
  • Fully shielded, fully submersible design withstands 500 lbs pull force
  • Molded conductive shield with grounding eye for deadfront construction

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
450 kcmil
Connection
Compression
Insulation
Yes
Material
Copper
Material
Copper Conductor
Material
EPDM Rubber
Number Of Conductors
2
Series
15PCJ1L2320
Size
1.180-1.465 inch (insulation diameter)
Size
1.180 inch to 1.465 inch
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 450.

15PCJ1K2320

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 450.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

25PCJ1G2230

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Solid 350.

15PCJ1J2290

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Solid 350.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 500.

15PCJ1K2330

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

15PCJ1G1260

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 750.

15PCJ1M2380

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 750.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ1L1270

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

15PCJ1K1300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

Frequently Asked Questions

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes. They provide a permanent, fully shielded, fully submersible splice.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

What is the maximum conductor size supported by PCJ joints?

PCJ power cable joints support conductors up to 1250 kcmil.

What is the short-time current rating for PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What standards do the PCJ joint shield and connectors meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the continuous current rating for PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What environments can PCJ power cable joints be installed in?

They can be installed in direct-burial, underground vault, and even overhead applications, providing a fully submersible splice.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What types of conductors are compatible with PCJ joints?

PCJ power cable joints are compatible with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ joints?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How to Install the 15PCJ1L2320 Single Core Joint

Installation guide for the 15PCJ1L2320 single core joint for extruded solid dielectric cables.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, PVC tape, Cleaning solvent, Clean cloth, Lubricant, Soldering iron or constant force spring tool, Heat gun

Supplies needed:

Joint Housing, Conductor splice, Flat copper braid, Mastic tape, Heat shrink tubing

  1. Prepare the Cables

    Train cables into position and square cut. Remove jackets to specified dimensions. Carefully remove metallic screen and secure ends with PVC tape. Remove non-metallic screen, bevel Cable 1, and cut insulation to 'E' dimension without removing it. Install PVC tape marker on Cable 2 to dimension 'B'.

  2. Prepare and Store the Joint Housing

    Apply PVC tape over the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B'. Lubricate both cable entrances of the splice housing. Clean and lubricate Cable 1 insulation, non-metallic screen, and PVC taped portion. Store the housing onto Cable 1 up to the jacket, ensuring the metallic screen is covered with PVC tape to prevent housing damage.

  3. Remove Cable Insulation and Install Connector

    Remove cable insulation from both cables without nicking. Wire brush exposed conductors. Insert conductors into the conductor splice, ensuring they are fully seated. Crimp the conductor splice according to the provided chart. Remove any sharp protrusions or burrs and clean the area. Wipe off excess inhibitor.

  4. Clean and Lubricate Core Surfaces

    Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, wiping towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant, wiping towards the screen end to create a ramp.

  5. Install the Joint Housing

    Slide the joint housing over the crimp connector into its final position. Ensure the distance 'X' between the joint housing and the PVC tape marker is equal on each side. Remove PVC tape to expose 25mm of copper tape.

  6. Restore Screen and Outer Jacket

    Wrap flat copper braid around each joint housing, overlapping onto the metallic tape screen by 20mm on each side. Attach the braid ends to the metallic tape screen by soldering or using a constant force spring. Lightly sand the outer surface of the jacket on both cables for 130mm and heat for 15 seconds. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it from the center outwards.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.