Overview

ABB Installation Products SKU 02702230 is a 15-35kV, 200 Amp Loadbreak LR Copper Contact designed for medium-voltage applications requiring reliable load interruption and connection. This copper contact accommodates either #1 AWG stranded/compressed or 1/0 AWG solid/compact conductors, providing flexibility in conductor sizing for distribution systems. The loadbreak feature allows for safe, hot-stick operation under load conditions, reducing downtime during maintenance or reconfiguration. The LR (Loadbreak Rated) designation confirms compliance with ANSI C119.4 standards for loadbreak operations up to 200A at rated voltage. Constructed from high-conductivity copper, this contact ensures minimal resistance and heat generation during operation. The design supports both solid and stranded conductors, making it suitable for utility, industrial, and commercial medium-voltage systems where standardized conductor configurations are required. Common applications include pad-mounted switchgear, transformers, and underground distribution systems where loadbreak capability and conductor compatibility are critical. The UNSPSC code 39121409 classifies this as a medium-voltage electrical contact, confirming its role in power distribution infrastructure.
  • Rated for 15-35kV, 200 Amp operations
  • Loadbreak capability per ANSI C119.4 standards
  • Compatible with #1 Stranded/Compressed or 1/0 Solid/Compact conductors
  • High-conductivity copper construction for low resistance
  • Designed for medium-voltage distribution systems

Specifications

Connection
Compression
Housing Material
Copper
Size
2.125 in
Type
Compression Lug One Hole
Wire Size
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.1100 L
Package Weight (Metric)
0.0500 kg
Locking Contact Pin and Crimp Barrel Assembly for Wire Size #1 Stranded AWG, 1/0 Solid or Compact AWG. Assembly consists of Stainless Steel Nose, Copper Locking Pin - Length 2 inch, Protective Cap, Aluminum Crimp Barrel - Length 2-3/16 inch and Disc Spring. Widest Diameter 5/8 inch.

01301230

Locking Contact Pin and Crimp Barrel Assembly for Wire Size #1 Stranded AWG, 1/0 Solid or Compact AWG. Assembly consists of Stainless Steel Nose, Copper Locking Pin - Length 2 inch, Protective Cap, Aluminum Crimp Barrel - Length 2-3/16 inch and Disc Spring. Widest Diameter 5/8 inch.
Heat Shrink Ring Terminal 12 10 AWG, 3/8" stud size.

PH10-38R-E

Heat Shrink Ring Terminal 12 10 AWG, 3/8" stud size.
Service Post Connector - Two Wire Type 4 STR Service Post Connectors is used for connecting one or two conductors. Made from high copper content hard-drawn rod. Lay-in feature makes them excellent for continuous loop grounding and bonding. Used to ground to bar or plate. Suitable for direct burial in earth or concrete.

SPM-24L

Service Post Connector - Two Wire Type 4 STR Service Post Connectors is used for connecting one or two conductors. Made from high copper content hard-drawn rod. Lay-in feature makes them excellent for continuous loop grounding and bonding. Used to ground to bar or plate. Suitable for direct burial in earth or concrete.
15-35kV 200 Amp, Loadbreak LR Copper Contact - 1/0 Stranded/Compressed or 2/0 Solid/Compact

02702240

15-35kV 200 Amp, Loadbreak LR Copper Contact - 1/0 Stranded/Compressed or 2/0 Solid/Compact
15-35kV 200 Amp, Loadbreak LR Copper Contact - 2/0 Stranded/Compressed or 3/0 Solid/Compact

02702250

15-35kV 200 Amp, Loadbreak LR Copper Contact - 2/0 Stranded/Compressed or 3/0 Solid/Compact
Aluminum H-Tap Connector, Wide Range, Industry Standard Size Code 2, Conductor Range Main ASCR 1/0, #1, #2, Stranded 2/0, 1/0, #1, #2, Solid 3/0, 2/0, 1/0, #1, #2 TAP ASCR #2, #4, #6, Stranded #1, #2, #3, #4, #6, Solid #2, #4, #6, Die O, 25 Pieces

WR189R

Aluminum H-Tap Connector, Wide Range, Industry Standard Size Code 2, Conductor Range Main ASCR 1/0, #1, #2, Stranded 2/0, 1/0, #1, #2, Solid 3/0, 2/0, 1/0, #1, #2 TAP ASCR #2, #4, #6, Stranded #1, #2, #3, #4, #6, Solid #2, #4, #6, Die O, 25 Pieces
15/25kV, 200 Amp, RLR Contact, Replacement Elbow Connector for Aluminum and Copper Conductors, 230 - for Conductor size #1 - Stranded/Compressed, 1/0 Compact/Solid

00400230

15/25kV, 200 Amp, RLR Contact, Replacement Elbow Connector for Aluminum and Copper Conductors, 230 - for Conductor size #1 - Stranded/Compressed, 1/0 Compact/Solid
15-35kV 200 Amp, Loadbreak LR Copper Contact - 3/0 Stranded/Compressed or 4/0 Solid/Compact

02702260

15-35kV 200 Amp, Loadbreak LR Copper Contact - 3/0 Stranded/Compressed or 4/0 Solid/Compact

Frequently Asked Questions

What conductor sizes does the 02702230 connector support?

The 02702230 connector supports #1 AWG for stranded/compressed and 1/0 AWG for solid/compressed copper conductors.

Which elbows are compatible with 02702XXX copper connectors?

They are designed for use with 161/162LR, 261/262LR, 375/376LR, and 252LR elbows.

What type of conductors are compatible with 02702XXX connectors?

These connectors are designed for use with copper conductors only.

What is included in the 02702XXX kit?

Each kit contains one 02702XXX connector and one Crimp Chart CC-0024.

What is the current rating of the 02702XXX connector?

The 02702XXX all copper connectors are rated for 200A loadbreak applications.

What conductor sizes does the 02702230 connector support?

The 02702230 connector supports #1 AWG for stranded/compressed and 1/0 AWG for solid/compressed copper conductors.

Which elbows are compatible with 02702XXX copper connectors?

They are designed for use with 161/162LR, 261/262LR, 375/376LR, and 252LR elbows.

What type of conductors are compatible with 02702XXX connectors?

These connectors are designed for use with copper conductors only.

What is included in the 02702XXX kit?

Each kit contains one 02702XXX connector and one Crimp Chart CC-0024.

What is the current rating of the 02702XXX connector?

The 02702XXX all copper connectors are rated for 200A loadbreak applications.

How to Install Elastimold 252LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing Elastimold 252LR Deadbreak Elbow Connectors, including cable preparation, assembly, and connection to a deadbreak bushing or accessory device.

Estimated time: 1h 30m

Tools needed:

Wrench, Crimp tool, Wire brush, Hot stick, Suitable sensing device (for voltage test), Wire strippers

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant (supplied), Hold-down Bail, UD cable (with concentric neutral and semi-con shielding), No. 14 AWG / 2.5mm copper wire, Appropriate connector (for grounding neutral wires), HV insulated cap(s) or connector(s) (if shipping covers are present)

  1. De-energize Apparatus and Inspect Parts

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. Inspect all parts for damage, rating, and compatibility with mating parts. If supplied with protective shipping cover(s), remove them and replace with appropriate HV insulated cap(s) or connector(s) before submerging or energizing the circuit.

  2. Perform Pre-installation Checks

    Ensure the unit will be bailed. Check the contents of the package to ensure they are complete and undamaged. Verify the elbow housing cable entrance size and compression lug size for proper fit with the cable. Check threads by threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component. Read the entire installation instruction before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.

  3. Train Cable

    Train the UD cable as shown in the diagram to ease operation, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing.

  4. Prepare Cable End

    Unwrap and bind the concentric neutral wires 8-1/2 inches (216.0mm) back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Remove the semi-con shield as shown in the cable cut-back template, and bevel the insulation end 1/8 inch (3.2mm) maximum.

  5. Install Compression Lug

    Wire brush bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Refer to the crimp chart packaged with the compression lug for recommended crimp tool information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.

  6. Clean Insulation

    Thoroughly clean the insulation to remove all traces of conductive residue after preparing the cable and installing the lug.

  7. Lubricate and Slide Elbow Housing

    Clean and lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Slide the elbow connector onto the cable with a back-and-forth twisting motion. Wipe off all excess silicone lubricant, keeping the insulation clean of dirt and grime.

  8. Thread and Tighten Probe

    Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten the probe with a wrench until the wrench bends, indicating proper torque.

  9. Place Hold-down Bail

    Place the hold-down bail into the hold-down bracket, compressing the bail and inserting it into the brackets.

  10. Connect Grounding Wire to Elbow

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow. Twist tightly, taking care not to damage the eye.

  11. Connect Neutral Wires to Ground

    Twist all concentric neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  12. Clean and Lubricate Mating Surfaces

    Clean the receptacle portion of the elbow connector and the mating bushing. Lubricate these surfaces with the lubricant supplied. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED.

  13. Connect Elbow to Bushing

    Use a fully insulated hot stick to place the elbow onto the bushing. DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.

  14. Secure Elbow with Hold-down Bail

    Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator, acting as a stop to prevent excessive force on the elbow. Once the nut is in its final position, it will not need readjustment when removing and replacing the elbow.

  15. Perform Voltage Test (Post-installation)

    To establish if the circuit is energized, remove the test point cap with a hot stick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for a suitable sensing device designed for capacitive test points. Contamination or incorrect equipment can cause a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.