Accessories

    Office Equipment and Accessories and Supplies

    Drives, Servos, and Motors

    Power Generation and Distribution Machinery and Accessories

    Structures, Building, and Construction

    Enclosures, Fans, and Environmental Controls

    Information Technology Broadcasting and Telecommunications

    Electronic Components And Supplies

    Safety Equipment and Supplies

    Tools and General Machinery

    Manufacturing Components and Supplies

    Distribution and Conditioning Systems and Equipment and Components

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Miscellaneous

Showing 673-684 of 10,147 results

Littelfuse SE-330AU-03-01 - SE-330AU-03-01 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; Ethernet (Dual RJ45).
Littelfuse · SE 330 Series

SE-330AU-03-01

SE-330AU-03-01


SE-330AU-03-01 is an advanced neutral-earthing resistor monitor with a supply voltage ac of 65–265 and a supply voltage dc of 85–275. Network communications is offered via USB; Ethernet (Dual RJ45).

Contact for Pricing

Littelfuse SE-325DS - SE-325DS is a neutral-grounding resistor monitor with a supply voltage of 120 ac-dc and a ground-fault trip level of 0.5–4.0 A.
Littelfuse · SE 325 Series

SE-325DS

SE-325DS


SE-325DS is a neutral-grounding resistor monitor with a supply voltage of 120 ac-dc and a ground-fault trip level of 0.5–4.0 A.

Contact for Pricing

Littelfuse SE-325DST - SE-325DST is a neutral-grounding resistor monitor with a supply voltage of 120 ac-dc and a ground-fault trip level of 0.5–4.0 A.
Littelfuse · SE 325 Series

SE-325DST

SE-325DST


SE-325DST is a neutral-grounding resistor monitor with a supply voltage of 120 ac-dc and a ground-fault trip level of 0.5–4.0 A.

Contact for Pricing

Littelfuse SE-325E - SE-325E is a neutral-grounding resistor monitor with a supply voltage of 240 ac and a ground-fault trip level of 0.5–4.0 A.
Littelfuse · SE 325 Series

SE-325E

SE-325E


SE-325E is a neutral-grounding resistor monitor with a supply voltage of 240 ac and a ground-fault trip level of 0.5–4.0 A.

Contact for Pricing

Littelfuse T3000.0050 - T3000 Frequency Relay. 120/127V. The T3000 is intended for effective frequency surveillance on generators, busbar or other distribution systems. The relay contains the functions “under frequency” and “over frequency” time delayed, and 2 individual output relays, one relay for each function.
Littelfuse · Relay Series

T3000.0050


T3000 Frequency Relay. 120/127V. The T3000 is intended for effective frequency surveillance on generators, busbar or other distribution systems. The relay contains the functions “under frequency” and “over frequency” time delayed, and 2 individual output relays, one relay for each function.

Contact for Pricing

Littelfuse T2700.0010 - Overload Relay. 230V L-N 5A. The T2700 Overload Relay will protect the generator from excessive active load. The T2700 is necessary to protect the prime mover and alternator against physical damage. The T2700 measures the current through an external 5A CT attached on phase L1. The phase angle (phi) is determined from the voltage measurement across L1 and L2. The T2700 calculates the active current as I x cos phi. If the active current exceeds the preset level (0.02 – 2 x I), the pick-up LED will ignite and the trip delay timer (0.1 – 10 seconds) will activate. The built-in trip relay will energize after the delay has passed, provided that the preset trip level was continuously exceeded during the time of the delay. Dials on the front facia provide easy adjustment of both trip level and delay. The LED based pick-up indication is ideal for testing the unit. Simplicity is the key to trouble free installation and service, as simplicity plays a key role in reducing the Total Cost of Ownership (TCO) for the complete supply system.
Littelfuse · Relay Series

T2700.0010


Overload Relay. 230V L-N 5A. The T2700 Overload Relay will protect the generator from excessive active load. The T2700 is necessary to protect the prime mover and alternator against physical damage. The T2700 measures the current through an external 5A CT attached on phase L1. The phase angle (phi) is determined from the voltage measurement across L1 and L2. The T2700 calculates the active current as I x cos phi. If the active current exceeds the preset level (0.02 – 2 x I), the pick-up LED will ignite and the trip delay timer (0.1 – 10 seconds) will activate. The built-in trip relay will energize after the delay has passed, provided that the preset trip level was continuously exceeded during the time of the delay. Dials on the front facia provide easy adjustment of both trip level and delay. The LED based pick-up indication is ideal for testing the unit. Simplicity is the key to trouble free installation and service, as simplicity plays a key role in reducing the Total Cost of Ownership (TCO) for the complete supply system.

Contact for Pricing

Littelfuse T4800.0060 - Load Sharer. 120/127V 5A. The T4800 is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4800 units). The T4800 will continuously measure and compare the active current on the generator to an external DC reference signal connected to the “parallel lines” input. The T4800 will increase or decrease the speed of the generator (through the governor) if it finds the active current level to be either too low or two high. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller.
Littelfuse · Relay Series

T4800.0060


Load Sharer. 120/127V 5A. The T4800 is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4800 units). The T4800 will continuously measure and compare the active current on the generator to an external DC reference signal connected to the “parallel lines” input. The T4800 will increase or decrease the speed of the generator (through the governor) if it finds the active current level to be either too low or two high. Two built-in relays provide the increase and decrease pulses for a conventional governor. The strength (width) of the pulses is proportional to the frequency/phase deviation. The E7800 Motorised Potentiometer can be used to adapt the contact pulses to a signal suitable for the speed trim input of an electronic speed controller.

Contact for Pricing

Littelfuse AC700-CUA-01 - EL700 SERIES COMM ADAPTER, Devicenet. Communications Adapter. Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.
Littelfuse · AC 700 Series

AC700-CUA-01


EL700 SERIES COMM ADAPTER, Devicenet. Communications Adapter. Optional network-interface and firmware-upgrade communications adapter. Field installs in EL731.

Contact for Pricing

Littelfuse EL731-13-00 - EL731-13-00 is an earth-leakage relay with a supply voltage ac of 24 and a supply voltage dc of 48. Communications is offered via EtherNet-IP™.
Littelfuse · EL731 Series

EL731-13-00

EL731-13-00


EL731-13-00 is an earth-leakage relay with a supply voltage ac of 24 and a supply voltage dc of 48. Communications is offered via EtherNet-IP™.

Contact for Pricing

Littelfuse G3100.0010 - G3100 Voltage Relay. 24V DC. The G-Line relays are mainly intended for use in land-based applications. The G-Line relays provide an efficient solution for applications where flexibility and cost of purchase are the main issues. G-Line relays provide high quality, proper measuring techniques and a vast number of programmable options.
Littelfuse · G3000 Series

G3100.0010


G3100 Voltage Relay. 24V DC. The G-Line relays are mainly intended for use in land-based applications. The G-Line relays provide an efficient solution for applications where flexibility and cost of purchase are the main issues. G-Line relays provide high quality, proper measuring techniques and a vast number of programmable options.

Contact for Pricing

Littelfuse B9300.0060 - Pwr Ref Unit380-450VOutput0-1VDCforT4800. Power Reference Unit. 380-450'V. Output 0-1V DC for T4800.
Littelfuse · B9300 Series

B9300.0060


Pwr Ref Unit380-450VOutput0-1VDCforT4800. Power Reference Unit. 380-450'V. Output 0-1V DC for T4800.

Contact for Pricing

Littelfuse E7800.0420 - Motorized Potentiomtr 230 VAC 10k 1 TURN. The E7800 Motorized Potentiometer is typically used as an interface between increase/decrease relay contacts (or push buttons) and a device requiring control by an external potentiometer (e.g. the speed trim of an electronic governor). All three wires of the potentiometer are directly accessible on external connection terminals, thus providing the best possible flexibility for almost any application. A special version of the E7800 with DC voltage output is also available. The DC output voltage follows the position of the potentiometer. The design of the E7800 ensures that the potentiometer will “remember” its position although supply is lost
Littelfuse · E7800 Series

E7800.0420


Motorized Potentiomtr 230 VAC 10k 1 TURN. The E7800 Motorized Potentiometer is typically used as an interface between increase/decrease relay contacts (or push buttons) and a device requiring control by an external potentiometer (e.g. the speed trim of an electronic governor). All three wires of the potentiometer are directly accessible on external connection terminals, thus providing the best possible flexibility for almost any application. A special version of the E7800 with DC voltage output is also available. The DC output voltage follows the position of the potentiometer. The design of the E7800 ensures that the potentiometer will “remember” its position although supply is lost

Contact for Pricing

Showing 673-684 of 10,147 results