Showing 121-132 of 20,882 results

Braking Resistor, 13 OHMS, 8125 WATTS, GCE15 Enclosure, 26.5W x 16D x 5H in, 33 lbs
Contact for Pricing

Contact for Pricing

DCT880 DC Drive, 3-480 VAC, 500 VDC In, 641 kW, 740A, Type OPEN, 1.1 overload, Base Controller, HxWxD 26.38x10.63x13.86 in, Wall, Internal UP Fuses (built-in) each leg
Contact for Pricing

MACHINERY DRIVE, Product Family: ACS850, Horsepower: 60 HP, Output Current: 90 A, Voltage: 480 VAC, Voltage Range: 380-500V, UL TYPE OPEN (IP20), Mounting: Cabinet-mounted (Side-by-Side), Control Unit Cover with Drive Mount Control Panel, ProfiBus-DP Adapter, EMC/RFI Filter (2nd Envir), 3-Phase Input, 3-Phase Output, Frame: D, Product HxWxD: 22.3 in x 8.7 in x 11.8 in, Product Weight: 51 lbs
Contact for Pricing

ACS380 AC Drive, 3-200-240V In, 3HP, 9.3A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
SALE
Contact for Pricing
READY TO SHIP NOW

Contact for Pricing

ACS880 AC Drive, 3-380-500V In, 700HP, 857A, Type OPEN, 1.1 overload, Assistant Bluetooth, HxWxD 68.54x13.78x19.92 in, Module, EMC/RFI-filters, 2nd Environment, Unrestricted (Unearthed Network), Common mode filter, DC cable connection busbars
Contact for Pricing

The data cable splitter is a 3-way 'Y' cable splitter suitable for a RS-485 network of drives. The option is compatible with standard CAT 5 or CAT 6 type cable and can be used for Modbus-RTU or an RS-485 remote keypad network.
Contact for Pricing

Absolute encoder interface (with PTC/KTY support) - has one absolute encoder input, one TTL encoder input, and one TTL encoder emulator output. The absolute encoder input supports a Sin/Cos incremental encoder, Endat 2.1, Endat 2.2, hiperface, or SSI with Sin/Cos signals at 5.5 or 8 Vdc. The TTL encoder input can operate at 5.5 or 24 Vdc. Both the encoder input and encoder emulator output are differential with a maximum frequency of 500 kHz.
Contact for Pricing

Braking Resistor, 8.06 OHMS, 5119 WATTS, GCE9 Enclosure, 26.5W x 10D x 5H in, 24 lbs
Contact for Pricing

The three phase field supply converters DCS800-S01 and -S02 drives need a separate active over voltage protection for proper operation on the inductive load of a motor field. This unit will protect the drive against inadmissible high voltages. The DCF506-0140 is to be used with -0020-05 through -0140-05 units.
Contact for Pricing

CABINET DRIVE ULTRA LOW HARMONIC, Product Family: ACS800, Horsepower: 450 HP, Output Current: 571 A, Voltage: 480 VAC, Voltage Range: 380-500V, NEMA 1 / UL Type 1 (IP21), Floor-mounted, Local or Remote Mounted LCD Display and Keypad, 0510 KVA, 3-Phase Input, 3-Phase Output, Frame: R8i, Product HxWxD: 91.1 in x 48.4 in x 25.4 in, Product Weight: 2090 lbs
Contact for Pricing