ABB Low Voltage Drives ABB-44476 Braking Resistor, 8.06 OHMS, 5119 WATTS, GCE9 Enclosure, 26.5W x 10D x 5H in, 24 lbs
Alternate Item Number: 3AUA0000015213
UPC: 662348000571
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Resistance: 8.06 ohms for precise energy dissipation
- Power rating: 5119 watts to handle high braking loads
- Compact dimensions: 26.5W x 10D x 5H inches for space-efficient installation
- 24 lbs weight for manageable handling and panel mounting
Specifications
Size | 26.5W x 10D x 5H in |
Frequently Asked Questions
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors increase the braking torque capability of a variable frequency drive, producing faster and more controlled braking by dissipating regenerated power.
What is the purpose of a braking chopper (module)?
Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power and prevent over-voltage trips.
How are Powerohm Type CR resistors constructed?
They feature a nickel-chromium wire helically wound inside a ceramic fixture, placed in a corrosion-resistant aluminum case with high-temperature wire leads.
What is the voltage range for ACS150 and ACS355 single-phase applications?
These drives are for single-phase 200-240V applications and are designed for stopping duty only.
What is the voltage range for ACS150 and ACS355 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications and are designed for stopping duty only.
What are the duty cycles mentioned for the resistors?
Duty cycles include 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.
What is the operating voltage for ACS250 single-phase drives?
ACS250 single-phase drives are available for 100-120V and 200-240V applications, all for stopping duty.
What is the operating voltage for ACS250 three-phase UL Type 4X drives?
These drives are for three-phase 200-240V and 380-480V applications, designed for stopping duty only.
What is the operating voltage for ACS250 three-phase drives (non-UL Type 4X)?
These drives are for three-phase 575-690V applications and are designed for stopping duty only.
What is the function of the thermal switch in Type GCE and ED enclosures?
The normally closed thermal switch detects resistor temperature overloads and is used for safety monitoring.