Littelfuse · Relay Series
T2900.0020
Differential Current Relay. 230V 5A. The T2900 offers protection of generators against differential currents. Visual indication of power, pick-up and relay tripping. High precision digital countdown timer for delayed output. Normal function upon loss of supply due to built-in energy source.
Contact for Pricing

Littelfuse · Relay Series
T3000.0030
T3000 Frequency Relay. 100/110V. The T3000 is intended for effective frequency surveillance on generators, busbar or other distribution systems. The relay contains the functions “under frequency” and “over frequency” time delayed, and 2 individual output relays, one relay for each function.
Contact for Pricing

EL731-00-00 is an earth-leakage relay with a supply voltage ac of 120–240 and a supply voltage dc of 120–240.
Contact for Pricing

ER-5WP is a sensing resistor accessory used on systems up to 5 kV ac and includes weather-protected terminals. It is an accessory for SE-330, SE-325, and SE-330AU.
Contact for Pricing

ER-25KV is a sensing resistor accessory used on systems up to 25 kV (non-continuous duty). It is an accessory for SE-330, SE-325, SE-330AU, and SE-330HV.
Contact for Pricing

ER-35KV is a sensing resistor accessory used on systems up to 35 kV (non-continuous duty). It is an accessory for SE-330, SE-330AU, and SE-330HV.
Contact for Pricing

EL731-02-00 is an earth-leakage relay with a supply voltage ac of 120–240 and a supply voltage dc of 120–240. Communications is offered via Profibus®.
Contact for Pricing

Contact for Pricing

Littelfuse · M3000 Series
M3000.0010
AnalogAlarm Annunciator24V DCInclM3092 P. The M3000 is a compact 24 channel Analogue Alarm Annunciator. The M3000 is ideal for surveillance of temperature sensors, pressure sensors and any other kind of sensors providing a signal within the range of 0-20 mA, 0-10 VDC or 0-30 VDC. A linearly pre-scaling is done in order to convert the measured input voltage or current into the entity measured by the sensor (e.g. temperature or pressure). Once this conversion has taken place, all further references are made to the measured entity.
Contact for Pricing

SE-325ST is a neutral-grounding resistor monitor with a supply voltage of 120 ac and a ground-fault trip level of 0.5–4.0 A.
Contact for Pricing

The PLMU11 continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation from 200 to 480 VAC and standard base connection allows the PLMU11 to replace hundreds of competitive part numbers. Operation: Upon application of power, a 0.6s random start delay begins and the PLMU11 measures the voltage levels and line frequency and selects the voltage range. The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. LED flashes green during trip delay, glows red when output de-energizes. undervoltage, overvoltage, and voltage unbalance must be sensed for continuous trip delay before the relay de-energizes. Reenergization is automatic upon fault correction. The output relay will not energize if a fault condition is sensed as 3-phase input voltage is applied. The LED alternately flashes red/green when phase reversal is sensed. Line voltage is selected with the knob, setting the over and under voltage trip points. Voltage range is automatically selected by the microcontroller.
Contact for Pricing

The DLMU Series is a universal voltage, 3-phase voltage monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and over or under frequency. Protection is assured during periods of large average voltage fluctuations or when regenerated voltages are present. The unit trips within 200ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10A, SPDT and 2A alarm output relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored; no connection to neutral is required. See datasheet for operation details.
Contact for Pricing